Background: Refractory/relapsed acute leukemia has always been a challenging problem for hematologist. Over the past decade emphasis has been made in the development of regimens containing fludarabine, combined with cytosine arabinoside for the treatment of refractory/relapsed acute leukemias. The aim of this study is to evaluate the efficacy and toxicity of the combination of fludarabine, high dose cytarabine, and granulocyte colony stimulating factor in refractory relapsed cases of acute leukaemia,
Methods: a prospective study is being conducted at the national center of hematology and hematology unit /Baghdad teaching hospital from July 2008 to July 2010.Twenty Patients with refractory/relapsed acute leukemia were treated with fludarabine 30mg/m2 and cytosine arabinoside (AraC) 2 g/m2 for 5 days, and granulocyte colony stimulating factor G-CSF 300 microgram/day from day 0 till neutrophil recovery (ANC >1.0 x 109/l).Response was evaluated by bone marrow examination on day 30-post chemotherapy.
Results: Patients included were refractory acute lymphoblastic leukemia (ALL) (n=5), relapsed ALL (n=4), refractory acute myeloid leukemia (AML) (n=8), relapsed AML (n=3). Complete remission (CR) was achieved in 9(45%) patients, 3 (15%) patients got partial remission. Three (15%) patients died of post chemotherapy complications and 5(25%) patient failed to achieve remission. Major complications encountered were: anemia, fever, bleeding, mucositis and bacterial infections.
Conclusion: FLAG protocol is well tolerated and effective regimen in relapsed / refractory acute leukemias. The toxicity is acceptable, enabling most patients to receive further treatment, including transplantation procedures
Two types of adsorbents were used to treat oily wastewater, activated carbon and zeolite. The removal efficiencies of these materials were compared to each other. The results showed that activated carbon performed some better properties in removal of oil. The experimental methods which were employed in this investigation included batch and column studies. The former was used to evaluate the rate and equilibrium of carbon and zeolie adsorption, while the latter was used to determine treatment efficiencies and performance characteristics. Expanded bed adsorber was constructed in the column studies. In this study, the adsorption behavior of vegetable oil (corn oil) onto activated carbon and zeolite was examined as a function of the concentr
... Show MoreIn this work we experimentally investigated SWCNTs and MWCNTs to increase their thermal conductivity and electrically functionalization process using different reagents ((nitric acid, HNO3 followed by acid treatment with H2SO4), then washed with deionized water (DW) and then treated with H2O2 via ultrasonic technique. Then repeated the steps with MWCNTs and compare their results in an effort to improve experimental conditions that efficiently differentiate the surface of the single walled carbon nanotubes (SWCNTs) and multi walled carbon nanotubesi(MWCNTs) that less nanotubes destroy and to enhance the properties of them and also to reduce aggregation in liquid. the results were prove by XRD, and infrared spectroscopy (FTIR). The FTIR sp
... Show MoreThis study is descriptive and theory of Dawn syndrome as the problem of research lies in the need to identify the identification of the causes of Dawn syndrome and its symptoms and methods of dealing with it, which has become a problem that needs treatment, especially after the numbers have become high in Iraq, which has not yet taken the necessary importance for treatment and care.
The objectives of the research were summarized in the identification of the most important causes of Dawn syndrome and its symptoms and diagnosis and ways or methods of dealing with people with Dawn syndrome in order to develop therapeutic plans for him.
... Show More
This research includes theoretical and evaluation design of a polarizer filter of high transmission in the near IR region of (900-1200nm) for different incidence angles to obtain a long wave and short wave pass filter using analytical calculations. Results refer to a new configuration design in fewer layers than used in previous studies in the long wave pass at incidence angles (45o,50o,55o). Adopted Hafnium dioxide (HfO2) and Magnesium fluoride (MgF2) as coating material at design wavelength (933nm), the study also included design short wave pass polarizer by using the same coating material.
Fast dissolving film can be defined as a dosage form, which when placed in the oral cavity. It will rapidly disintegrate and dissolves to release the medication for oral mucosal absorption or allow for the gastrointestinal absorption to be achieved when swallowed.
Flurbiprofen is non-steroidal anti-inflammatory agent with antipyretic and analgesic properties and can be used in low doses 8.75 mg as analgesic and anti inflammatory agent in sore throat infection. This study aims to formulate flurbiprofen as oral dissolving films, to improve the effective relief of pain with severe sore throats with little or no adverse effect.
Nine formulas were prepared using solvent-casting method, and t
... Show MoreIn this work, we have examined the spectral response of (p-CuAlSe2/n-Si) detector, (CAS) thin films deposited by thermal evaporation at RT with a thickness (450) nm, and annealing temperature at (473K) for 2 h. Optical transmission measurements displayed reasonably slight transmission besides higher absorbance trendy the visible region, energy gaps were observed by annealing, were found to be direct, and decreased with the effect of annealing. The extreme responsivity value arises at wavelength 459 nm, with improvement value of specific detectivity and quantum efficiency the annealing films be situated originate as greatest suitable aimed at numerous device application.
Background: The anterior loop of mental nerve is commonly described as that part of the neurovascular bundle that transverses anterior and inferior to the mental foramen only to loop back to exit the mental foramen. The aim of the study is to evaluate the incidence and extension of anterior loop of mental nerve by using digital panoramic imaging system to avoid nerve damage during different surgical procedures in dentistry. Materials and Method: Panoramic image was taken for all 400 patients and stored in the computer. Then Horizontal and Vertical for the anterior loop extension when exist was measured and recorded in a special case sheet prepared for each subject. Results: Results indicated that out of 400 patients there were only 25 pat
... Show More