Background : Coronary artery disease is theunderlying cause in approximately two thirds of
patients with systolic heart failure ;
Coronary artery angiogriphy may be useful to
define the presence ,
Anatomical characteristics ,and functional
significance of Coronary artery disease in
selected heart failure patients with or without signs
and aymptoms of Coronary artery disease.
Objectives: to verify the clinical usefulness of
coronary angiography (CA) in congestive heart
failure (CHF) patients with no history of ischemic
heart disease and to identify predictive factors for
performing coronary angiography to patients with
congestive heart failure with no obvious ischemia.
Methods :this is a cross-sestional study conducted
Ibn al –Bitar center for cardiac surgery during a
period between November 2009 and November
2010 ;all included patients have symptomatic LV
dyfunctional with NYHA functional class II or
more with no clinical evidence of IHD .History,
physical examination had been performed for each
patient , in addition ti blood tests ,ECG ,CXR,
echocardiography and Coronary angiogriphy
Results :Among 112 patients with symptomatic
LV dysfunction of unknown cause enrolled in this
study male :female ratio 3:1 their age (17 -77 years
)there were 14 patients (12.5%)with significant
Coronary artery disease , statistical analysis
between CADand non CAD group show :the CAD
were more common in male 11 patients (78% )
smokers(1)Were female , 25 patients (22.3%) were
diabetic , 25 diabetic (22.3%) were hypertensive
,50 diabetic (44.6%) were smokers . 4 diabetic3.5) with family history of dilatedhyperlipidemia and 3 diabetic (2.6%) ) with
family history ischemic heart disease (IHD in
close relative at age <50 years in men and <55
years in women ) as demographic distribution of
patients in table 1 .coronary angiography show
that are 14 patients (12.5%) with significant
coronary artery disease (CAD) and 98 patients
(87.5%) with significant coronary artery disease
. as shown in figure 1 . eleven patients (78%) of
patients (22%) were female statistical analysis
shows that the male is more predominant in
CAD groups as shown in table 2 . twelve
patients (85.7%) of patients with CAD were
smokers while only 38 patients (38.7%) were
smokers in non CAD group . statistical analysis
shows there is significant difference between
the two groups ( p value < 0.01 ) as shown in
table 3 .nine patients (64.2%) of patients with
CAD were diabetics while 16 patients
(16.3%)were diabetics in non CAD group ,
statistical analysis shows there is significant
difference between the two groups (p value <
0.005) as shown in table (3) .there is no
statistical between the mean of left ventricular
ejection fraction of CAD group ( 37 ±10 %) and
that of non CAD (36±9 % ) , p value > 0.5 as
shown in table 6 . figure 2 revealed that LAD
lesion was most common coronary artery lesion
which represent 12 (85%) followed by in order
of frequency LCX 42 % ,RCA 28% and LMS
7% ; in addition to that 57% with single vessel
disease ,14.2% with 2 vessel disease and
28.4%with r vessel disease (2)Leads , ST
depression ≥1 mm or deep T wave inversion
had been excluded
(
Synthesis of a new class of Schiff-base ligand with a tetrazole moiety to form polymeric metal complexes with CoII, NiII, ZnII, and CdII ions has been demonstrated. The ligand was synthesised by a multi-steps by treating 5-amino-2-chlorobenzonitrile and cyclohexane -1,3-dione, the 5,5'-(((1E,3E)-cyclohexane-1,3-diylidene)bis(azanylylidene))bis(2-chlorobenzonitrile) was obtained. The precursor (M) was prepared from the reaction 5,5'-(((1E,3E)-cyclohexane-1,3-diylidene)bis(azanylylidene))bis(2-chlorobenzonitrile) with NaN3 to obtained (1E,3E)-N1,N3-bis(4-chloro-3-(1H-tetrazol-5-yl)phenyl)cyclohexane-1,3-diimine (N). By reacting the precursor (M) with CS2
... Show More<span lang="EN-US">The fundamental of a downlink massive multiple-input multiple-output (MIMO) energy- issue efficiency strategy is known as minimum mean squared error (MMSE) implementation degrades the performance of a downlink massive MIMO energy-efficiency scheme, so some improvements are adding for this precoding scheme to improve its workthat is called our proposal solution as a proposed improved MMSE precoder (PIMP). The energy efficiency (EE) study has also taken into mind drastically lowering radiated power while maintaining high throughput and minimizing interference issues. We further find the tradeoff between spectral efficiency (SE) and EE although they coincide at the beginning but later their interests become con
... Show MoreAlbizia lebbeck biomass was used as an adsorbent material in the present study to remove methyl red dye from an aqueous solution. A central composite rotatable design model was used to predict the dye removal efficiency. The optimization was accomplished under a temperature and mixing control system (37?C) with different particle size of 300 and 600 ?m. Highest adsorption efficiencies were obtained at lower dye concentrations and lower weight of adsorbent. The adsorption time, more than 48 h, was found to have a negative effect on the removal efficiency due to secondary metabolites compounds. However, the adsorption time was found to have a positive effect at high dye concentrations and high adsorbent weight. The colour removal effi
... Show MoreAim: The current study was aimed to determine the relationship between the orthodontic force applied by monobloc and the salivary level of alkaline phosphatase (ALP) and lactate dehydrogenase (LDH) enzymes, considering the time factor after insertion of the appliance and whether there is a correlation between these enzymes. Materials and methods: A sample of 28 growing patients requiring orthodontic treatment with myofunctional appliance (Monoblock) was taken for the current study with an age range 9 to 12 years,all patients had Angle's class II division 1 malocclusion with no or mild crowding, the sample was selected using simple random sampling. Only 16 subjects (10 males and 6 females) were included who follow certain inclusion criteria.
... Show MoreBackground: The rising rate of cesarean deliveries has generated concern about whether all procedures are medically justified. Limited data exist on how well first-time mothers understand the indications for their cesarean section in Iraq. Objective: To assess maternal knowledge of the medical reasons for the first cesarean delivery and its relationship with sociodemographic, obstetric, and neonatal characteristics. Methods: A cross-sectional study was conducted from October to December 2023 among 158 Iraqi women who underwent their first cesarean delivery. Data were collected using a structured, self-administered online questionnaire that assessed demographic, obstetric, and knowledge-related factors. Results: Less than half of the
... Show MoreThis study includes the preparation of the ferrite nanoparticles CuxCe0.3-XNi0.7Fe2O4 (where: x = 0, 0.05, 0.1, 0.15, 0.2, 0.25, 0.3) using the sol-gel (auto combustion) method, and citric acid was used as a fuel for combustion. The results of the tests conducted by X-ray diffraction (XRD), emitting-field scanning electron microscopy (FE-SEM), energy-dispersive X-ray analyzer (EDX), and Vibration Sample Magnetic Device (VSM) showed that the compound has a face-centered cubic structure, and the lattice constant is increased with increasing Cu ion. On the other hand, the compound has apparent porosity and spherical particles, and t
... Show MoreIt is often needed to have circuits that can display the decimal representation of a binary number and specifically in this paper on a 7-segment display. In this paper a circuit that can display the decimal equivalent of an n-bit binary number is designed and it’s behavior is described using Verilog Hardware Descriptive Language (HDL). This HDL program is then used to configure an FPGA to implement the designed circuit.
We studied the effect of certain environmental conditions for removing heavy metal elements from contaminated aqueous solutions (Cd, Cu, Pb, Fe, Zn, Ni, Cr) using the bacterium Bacillus subtilis to appoint the optimal conditions for removal ,The best optimum temperature range for two isolate was 30-35○C while the hydrogen number for the maximum mineral removal range was 6-7. The best primary mineral removal was 100 mg/L, while the maximum removal for all minerals was obtained after 6 hrs of Cu element time and the maximum removal efficiency was obtained after 24 hrs of Cu element. The results have proved that the best aeration for maximum removal was obtained at rotation speed of 150 rpm/minute. Inoculums of 5ml/100ml which contained 1
... Show More