Background: Humeral diaphyseal fracture usually
heals with closed methods but when nonunion
develops then it needs surgical intervention in the
form of plating and bone grafting, intramedulary
nailing (open or closed simple or interlocking nails)
and external fixators (circular or one plane fixator).
In our unit we treated non union humeral
diaphyseal fracture with plating and bone grafting
shortening of fracture ends up to 4 to 5cm when
needed. Methods: This study was conducted at
Orthopaedic Department of AL-Sadar General
Hospital from January 2004 till December2005 .
We included 20 cases with atrophic non-union in
12(60%) and hypertrophic non-union in 8 (40%)
patients. All atrophic non-union were treated with
plating, bone shortening by transverse osteotomy
and bone grafting, while hypertrophic non-union
were treated with decortications of non-union ends
and fixation with compression plates, with bone
grafting in old age. Follow up measures were based
on clinical (range of joints motion) and radiological
(healing) findings. Follow up was done for upto 6
months . Results: Out of 20 patients the age range
was 20- 60 years, 16 (80%)were male and 4(20%)
female. Right humerus involved in 15( 75 %)
while left humerus in 5( 25%) patients.
In12(60%) patients with atrophic non union bone
shortening by transverse cut osteotomy was done
while in remaining patients with hypertrophic nonunion
plating was done in 2( 10 %) cases and
plating with bone grafting in 6( 30%) patients.
Union was achieved in all patients after 16 to 20
weeks of surgery. In one patient ( 5 %) of 75 years
age with hypertrophic non-union implant was
loosened after 3 months of surgery. At that time
healing (Union) was evident on X-rays and humeral
brace was applied for further 3 months. Two
patients( 10 %) got neuropraxia of radial nerve
which resolved with in 3 months time. 2 patients
(10 %) developed shoulder stiffness which resolved
after exercise. Conclusion: In Non Union of
Humerus shortening by transverse osteotomy &
rigid fixation with plates give excellent results in
selected cases.
In this study, the effect of design parameters such as pipe diameter, pipe wall thickness, pipe material and the effect of fluid velocity on the natural frequency of fluid-structure interaction in straight pipe conveying fully developed turbulent flow were investigate numerically,analytically and experimentally. Also the effect of support conditions, simply-simply and clamped-clamped was investigated. Experimentally, pipe vibrations were characterized by accelerometer mounted on the pipe wall. The natural frequencies of vibration were analyzed by using Fast Fourier Transformer (FFT). Five test sections of two different pipe diameters of 76.2
mm and 50.8 mm with two pipe thicknesses of 3.7 mm and 2.4 mm and two pipe materials,stainles
This study aims to Statement of the relationship between Total Quality Management philosophy and Organizational performance from the point of view of the internal customer. A comparison has been made between two companies, one of which applies the requirements of TQM well and the other does not apply these requirements as the (General Company for Electrical Industries/ Diyala) and (General Company for Electrical Industries/ Baghdad) to conduct the search, During the questionnaire prepared for this purpose and distributed to a sample of 30 employees in the General Company for Electric Industries/ Diyala and (20) employees of the General Company for Electrical Industries/ Baghdad. Their answers were analyzed using a simple correlation coef
... Show MoreBackground/purpose: Dental implantology involves different treatments that have been used in conjunction with dental implant surgery to increase implant stability and bone regeneration process. Photobiomodulation( PBM) can be one of these techniques. The objective of this study was to evaluate the bone density around implants. Materials and methods: in this study, 10 individuals had 20 implants inserted in the posterior of their mandibles. each patient received two implants the left side served as the control whereas the right side served as the study group with a diode laser (same patients). measurements were made for each implant. Measurements were obtained using cone-
... Show MoreIn this paper, An application of non-additive measures for re-evaluating the degree of importance of some student failure reasons has been discussed. We apply non-additive fuzzy integral model (Sugeno, Shilkret and Choquet) integrals for some expected factors which effect student examination performance for different students' cases.
This paper presents a numerical simulation for the combined effect of surface roughness and non-Newtonian behavior of the lubricant on the performance of misaligned journal bearing. The modified Reynolds equation to include the effect of non-Newtonian lubricant and bearing surface roughness has been formulated. The model accounts for the lubricant viscosity dependence on temperature and shear rate. In order to make a complete thermo-hydrodynamic analysis (THD) of rough surface misaligned journal bearing lubricated with non-Newtonian lubricant, the modified Reynolds equation coupled with the energy, heat conduction equations, the equation related the viscosity and temperature with appropriate boundary conditions have been solved simultane
... Show MoreBackground: Radial neck fractures in children account for 5 to 10% of all elbow fractures in children. They are extra-articular fractures of the radius proximal to the bicipital tuberosity. The physis is typically involved as a Salter-Harris I or II pattern. Alternatively, the fracture sometimes is extraphyseal, through the metaphysis. In children there is considerable potential for remodeling after these fractures. Up to 30° of radial head tilt and up to 3 mm of transverse displacement are acceptable. Many modalities of treatment are available regarding Surgical &Non-Surgical treatments. Objectives: To evaluate the functional outcome after surgical percutaneous joystick reduction therapy of severely angulated radial neck fracture i
... Show MoreBACKGROUND: Transverse fractures of the patella are important fractures with a wide variety of subtypes, the common incidence in the age group of 20–50 years. Surgical interference aims to achieve a perfect alignment of the joint surface, in addition to rigid fixation of the fracture for early re-habitation and early movement to retain the extensor mechanism of the knee joint. AIM: The aim of this study was to compare the radiological and functional outcomes of the displaced transverse patella fracture in adult patients treated by ORIF using tension band wiring versus cannulated screws with wiring. METHODS: A prospective analytic comparative study was conducted in Al-Kindy Teaching Hospital/Baghdad/Iraq for 18 months from Apr
... Show MoreBackground: Radial neck fractures in children account for 5 to 10% of all elbow fractures in children. They are extra-articular fractures of the radius proximal to the bicipital tuberosity. The physis is typically involved as a Salter-Harris I or II pattern. Alternatively, the fracture sometimes is extraphyseal, through the metaphysis. In children there is considerable potential for remodeling after these fractures. Up to 30° of radial head tilt and up to 3 mm of transverse displacement are acceptable. Many modalities of treatment are available regarding Surgical &Non-Surgical treatments. Objectives: To evaluate the functional outcome after surgical percutaneous joystick reduction therapy of severely angulated radial neck fracture i
... Show More