Preferred Language
Articles
/
jkmc-474
Discrimination of Malignant from Acute Benign Compression Spinal Fractures with Magnetic Resonance imaging
...Show More Authors

Background: Differentiation between malignant and benign vertebral compression fracture is often problematic. This is precisely difficult in elderly who are predisposed to benign compression caused by osteoporosis .Establishing correct diagnosis is of great importance in determining the treatment andprognosis.A study was performed to determine which magnetic resonance imaging findings are useful in discrimination between metastatic and acute osteoporotic compression fractures of the spine. Recently MRI is being increasingly used for evaluation of these fractures.Objectives: The aim of this study is to establish the correct diagnosis of malignant and benign compression vertebral fracture by MRI to determine treatment and prognosis.Methods: MRI of (45 )patients with vertebral compression fracture who underwent MRI of spine during 2 years period ( 2004-2006) in Neuro surgical hospital were retrospectively reviewed by an expedient radiologist , A collapsed vertebra were considered to be acute if there was recent history of back pain of less than 3moths. All MRI sequences needed for spine examination was done( T1WI SE, T2WI GE STIR, and Mylography ) and Gadolinium contrast medium was given to all patients..Results: Of total 45 patients (31male, 14 female, their age range between 18-72years) , The criteria used to differentiate between benign andmalignant collapse spine on MRI was based on the signal intensity, morphology and contrast enhancement for the correct diagnosis. Homogenous and diffuse abnormal signal intensity, posterior convexity and involvement of pedicles are sign that are strongly suggestive of malignant collapse .Conversely, a band like area of low signal intensity adjacent to depressed end plateand preservation of signal intensity of vertebra suggest benign nature of the collapse.Conclusions: We found that MRI features is helpful in differentiation of malignant and benign compression fractures in majority of cases, and if initial MRI finding are equivocal correlation with other images technique, follow up and biopsy in selected cases helpful in arriving correct diagnosis

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon May 01 2017
Journal Name
Journal Of Nuclear Medicine
A hand-held hybrid gamma-near-infrared fluorescence imaging camera
...Show More Authors

Objectives: Recently, there have been important advances in the clinical application of targeted hybrid near-infrared (NIR) fluorescent-radioactive tracers. ICG-99mTc-nanocolloid, for example, is already being used by some centres for sentinel lymph node biopsy in head and neck cancer. The radioactive component allows imaging at depths which would not be possible with NIR alone and, once exposed, the NIR fluorescence reporter can be imaged at very high resolution. Gamma detection is currently carried out with a separate hand-held gamma camera or with a non-imaging probe. Visualisation of NIR fluorescence during surgery requires a dedicated NIR camera, several of which are available commercially. We describe a novel hand-held hybrid NIR-gamm

... Show More
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Photoacoustic Imaging for Tumor Detection: An in vitro Simulation Study
...Show More Authors

Photoacoustic is a unique imaging method that combines the absorption contrast of light or radio frequency waves with ultrasound resolution. When the deposition of this energy is sufficiently short, a thermo-elastic expansion takes place whereby acoustic waves are generated. These waves can be recorded and stored to construct an image. This work presents experimental procedure of laser photoacoustic two dimensional imaging to detect tumor embedded within normal tissue. The experimental work is accomplished using phantoms that are sandwiched from fish heart or blood sac (simulating a tumor) 1-14mm mean diameter embedded within chicken breast to simulate a real tissue. Nd: YAG laser of 1.064μm and 532nm wavelengths, 10ns pulse duration, 4

... Show More
View Publication Preview PDF
Publication Date
Thu Jun 30 2016
Journal Name
Al-kindy College Medical Journal
Evaluation of the Intrinsic Pathway of Coagulation in a Sample of Iraqi Patients with Acute Myocardial Infarction
...Show More Authors

Background: Acute myocardial infarction (AMI) is one of the most common diagnoses in hospitalized patients. Increased plasma hemostatic markers were noted in acute myocardial infarction, indicating that the blood coagulation system is highly activated in those patients. Aims of the study: To study the level of intrinsic coagulation factors including (FVIII:C, FIX:C ,FXI:C ,FXII:C ) in patients with acute myocardial infarction. Type of the study: Cross –sectional study. Methods: Thirty patients (their age range is 48-68 years) were included in this study (9 female, 21 male) who were just admitted to the coronary care unit in AL-Yarmouk Teaching Hospital and diagnosed as having acute myocardial infarction patients, blood samples were tak

... Show More
View Publication Preview PDF
Publication Date
Sun Dec 12 2021
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
The Acute Toxicity of Rutin in Mice
...Show More Authors

Acute toxicity is a step to evaluate the toxicity of a substance. Rutin is one of the flavonoid compounds with a variety of pharmacological effects. The aim of the study is to calculate the lethal dose that affect fifty percent of the mice used in the experiment (LD50). Thirty Swiss albino male and 30 non-pregnant female mice have been divided equally and randomly into 5 treated groups and one control group (n=5)  Rutin has been administered with  concentrations 5, 2.5.1.25,0.625 and 0.312 g/kg administered as a single dose intraperitoneally (IP) while the control group received 1% DMSO (IP).  Animals were observed for any morbidity and mortality for 14 days. After 14 days the animal blood collected for biochemical and hem

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (3)
Scopus Crossref
Publication Date
Mon May 29 2023
Journal Name
Rawal Medical Journal
Comparison of functional and radiological outcomes of lower third closed tibia fractures treated by nail VS plate osteosynthesis
...Show More Authors

Objective: To determine the functional and radiological outcomes of lower third tibia closed fractures fixed by nail or plate osteosynthesis. Methodology: This randomized controlled trial included 20 patients presenting with closed fracture lower third tibia in Al-Kindy teaching hospital, Baghdad, Iraq. The patients were divided as every other one into two equal groups; group I had fractures fixed by 3.5 mm locked plate and group II by intramedullary locking nail. We followed all patients for 24 weeks to assess surgical complications, fracture union, alignment and functional outcome based on Knee society score (KSS). Results: The mean union time in both groups was 10.2 ± 1.48 and 9.3 ± 1.77 weeks, respectively (p = 0.003). Mean KSS in bot

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Fri Apr 01 2016
Journal Name
Iosr Journal Of Computer Engineering
Lossless and Lossy Polynomial Image Compression
...Show More Authors

Crossref (1)
Crossref
Publication Date
Sat Jul 01 2017
Journal Name
Diyala Journal For Pure Science
Correlated Hierarchical Autoregressive Models Image Compression
...Show More Authors

View Publication
Crossref
Publication Date
Fri Apr 01 2016
Journal Name
Iosr Journal Of Computer Engineering
Lossless and Lossy Polynomial Image Compression
...Show More Authors

View Publication
Crossref (1)
Crossref
Publication Date
Fri Aug 31 2012
Journal Name
Al-khwarizmi Engineering Journal
Sub–Nyquist Frequency Efficient Audio Compression
...Show More Authors

This paper presents the application of a framework of fast and efficient compressive sampling based on the concept of random sampling of sparse Audio signal. It provides four important features. (i) It is universal with a variety of sparse signals. (ii) The number of measurements required for exact reconstruction is nearly optimal and much less then the sampling frequency and below the Nyquist frequency. (iii) It has very low complexity and fast computation. (iv) It is developed on the provable mathematical model from which we are able to quantify trade-offs among streaming capability, computation/memory requirement and quality of reconstruction of the audio signal. Compressed sensing CS is an attractive compression scheme due to its uni

... Show More
View Publication Preview PDF
Publication Date
Mon May 01 2017
Journal Name
The Journal Of Immunology
Protective effects of Δ9-Tetrahydrocannabinol (THC) results from alteration in lung dysbiosis mediated by SEB-induced acute lung injury
...Show More Authors
Abstract<p>Inhalation of Staphylococcal Enterotoxin B (SEB) is known to induce acute lung injury (ALI) and studies from our laboratory have shown that THC, a psychoactive ingredient found in Cannabis sativa, can attenuate the ALI. In the current study, we investigated the role played by lung microbiota in ALI with or without THC treatment. A dual-dose of SEB was given to C3H/HeJ mice, which were then treated either with vehicle or THC. SEB-administration caused ALI and 100% mortality while all THC-treated mice survived and suppressed the inflammation in the lungs. Furthermore, lung microbiota was collected and 16S rRNA sequencing was performed. The data were analyzed to determine the alpha and b</p> ... Show More
View Publication Preview PDF
Crossref