Cesarean section, which was introduced into clinical practice as a lifesaving procedure for both the mother and the baby, is one of the most common surgeries performed in modern obstetrics. Formerly it was performed in interest of the mother; currently it is frequently done for fetal indication. As other procedures of some complexity, its use follows the health care inequity pattern of the world; underuse in low income setting, and adequate or even unnecessary use in middle and high income setting (1).
The first modern cesarean section was performed by German gynecologist Ferdinand Adolf Kehrer in 1881. Cesarean section is often performed when a vaginal delivery would put the baby's or mother's life or health at risk. Many are also performed upon request (2).
Pregnancy and delivery are considered a normal physiological state in women; however, of all deliveries approximately 10% are considered high risk, some of which may require Cesarean section (3).
The cesarean delivery rate has increased throughout the world. Cesarean rates have increased over the past 40 years from approximately 5% to more than 30% in many industrialized countries (4). The cesarean rate is approximately 21.1% for the most developed regions of the globe, 14.3% for the less developed regions, and 2% for the least developed regions (5).
Recent studies reaffirm earlier recommendations of the world health organization (WHO), about optimal C-section rates, addressing that the best outcomes of mothers and babies appear to occur with C-section rates of 5% to 10%, while rates above 15% seem to do more harm than good (6).
In US the cesarean rate increased dramatically during the 1970s and early 1980s this may be accredited to the improved technology in detecting pre-birth distress, and began to decline in the late 1980s (based on data from the National Hospital Discharge Survey). Between 1989 and 1996 the total cesarean rate decreased as a result of a decrease in the primary rate and an increase in the rate of vaginal birth after Cesarean (VBAC). Since 1996, these trends have reversed, and increases have been rapid and sustained for primary and repeat Cesareans over the past decade (7).
According to the Iraq Multiple Indicator Cluster Survey 2006 (Iraq MICS 2006) (8), about 20% of births were delivered by C-section (Table 1). Moreover, a brief and rapid survey of C-sections in Baghdad Teaching Hospital, a tertiary referral hospital, indicated that the emergency C-sections account only for 62.2% of the total number of C-sections performed outside the working hours during April 2010 (9).
The electrochemical behavior of carbon steel in water sweetening station in Libya has been studied in the range of ( 293–333 oC) using weight loss technique. Measurements were carried out over a range of Reynolds number (5000 – 25000).An apparatus was designed for studying the corrosion process in the turbulent regime, which is of industrial significance. It was found that The corrosion rate of carbon steel in water sweetening station is under diffusion control and increases with increasing Reynolds number. On the other hand the variation of corrosion rate with temperature in the range of (293–333 oC) was found to follow Arrhenius equation and the activation energy approximately the same except at low Reynolds
... Show MoreLipase enzyme has attracted a lot of attention in recent years because of its diverse biotechnological applications. The present study was conducted to screen germinated seeds of four crops, namely sunflower (Helianthus annuus), flaxor linseed (Linum usitatissimum ), peanut (Arachis hypogaea ) and castor bean (Ricinus communis), for the activity of their lipases. to the study also included the extraction and purification of lipase from the seeds of the most promising crop using different solvents. The results indicated that the maximum enzymatic activity (0.669 U/ml) was obtained when 0.1 M Tris-HCl buffer extract was used after 3 days of seed germination of all the tested species, as compared to the other test solvents
... Show MoreThe study investigated the behaviour of asphalt concrete mixes for aggregate gradations, according to the Iraqi specification using the Bailey method designed by an Excel spreadsheet. In mixing aggregates with varying gradations (coarse and fine aggregate), The Bailey method is a systematic methodology that offers aggregate interlocking as the backbone of the framework and a controlled gradation to complete the blends. Six types of gradation are used according to the bailey method considered in this study. Two-course prepared Asphalt Concrete Wearing and Asphalt Concrete binder, the Nominal Maximum Aggregate Sizes (NMAS) of the mixtures are 19 and 12.5 mm, respectively. The total number of specimens was 240 for both layers (15 samp
... Show MoreAbstract
Stainless steel (AISI 304) has good electrical and thermal conductivities, good corrosion resistance at ambient temperature, apart from these it is cheap and abundantly available; but has good mechanical properties such as hardness. To improve the hardness and corrosion resistance of stainless steel its surface can be modified by developing nanocomposite coatings applied on its surface. The main objective of this paper is to study effect of electroco-deposition method on microhardness and corrosion resistance of stainless steel, and to analyze effect of nanoparticles (Al2O3, ZrO2 , and SiC) on properties of composite coatings. I
... Show MoreAbstract Objective: To assess nurses' beliefs toward reporting suspected child abuse. To achieve the objectives of the study a questionnaire of child abuse was used. Methodology:- The sample of the study consist of (224) registered nurses who were employed in general hospitals, pediatric hospitals, National psychiatry and mental illness center, nursing colleges, nursing schools. Data were collected from 20 April 2004 to 20 June 2004.Data were analyzed through the application of descriptive statistical analysis. Percentage frequency and mean and inferential data analysis ANOVA. Results: - The result of t
The stability and releasing profile of 2:1 core: wall ratio ibuprofen microcapsules prepared by aqueous coacervation (gelatin and acacia polymers coat) and an organic coacervation methods (ethyl cellulose and sodium alginate polymers coat) in weight equivalent to 300mg drug, were studied using different storage temperatures 40°C, 50°C ,60°C and refrigerator temperature 4°C in an opened and closed container for three months (releasing profile) and four months (stability study).It was found that, these ibuprofen microcapsules were stable with expiration dates of 4.1 and 3.1 years for aqueous and an organic method respectively.Aqueous prepared ibuprofen microcapsules were found more stable than those microcapsules prepared by or
... Show MoreBackground: Breast cancer is the first one among Iraqi females. Most of them present later for diagnosis. Early detection center in tertiary hospital practice uses FNAB for early diagnosis. Publications on accuracy of this detection are scarce.
Objective: To test the accuracy of FNAB in breast lump diagnosis.
Methods: Diagnostic test accuracy study, on 204 women with breast lump, attending the oncology department in 2017.
Results: Fine-needle aspiration biopsy diagnosis of histologically malignant cases were, malignant in 89 (87.3%), suspicious of malignancy in 5 (4.9%), and benign in 4 (3.9%). Complete sensitivity was 87.3%, and specificity
... Show More