ABSTRACTBackground: cochlear implants are electronic devices that convert sound energy into electrical signals to stimulate ganglion cells and cochlear nerve fibers. These devices are indicated for patients with severe to profound sensorineural hearing losses who receive little or no benefit from hearing aids. The implant basically takes over the function of the cochlear hair cells. The implant consists of external components (microphone, speech processor and transmitting coil) and internal components (receiver stimulator and electrode array). The implant is inserted via a trans mastoid facial recess approach to the round window and scala tympani.Objectives: to determine the effectiveness and safety of non fixation method in cochlear implantation.Methods: a prospective study carried out from September 2009 to September 2012 in Gazi Hariri Hospital. Eighty patients with congenital severe –profound sensorineural hearing loss prepared for cochlear implantation involved in the study and divided into 2 groups. Group A includes 40 patients in whom the internal device was fixed to the skull by nylon suture materials through small burr holes on both sides of the well. Group B includes 40 patients in whom the internal device placed in a tight sub pericranial pocket without nylon fixation to the skull. All patients followed postoperatively for 6 months observing wound healing and local complications (hematoma, infection, wound dehiscence, device extrusion and migration).Results: mean age 4.2 years and male-female ratio was 1.3:1.Group A: 1 patient (2.5%) developed minor wound infection treated conservatively. Three patients (7.5%) developedsevere wound infection with wound breakdown and device extrusion despite the use of antibiotics and local rotational flaps, the device was explanted in those 3 patients. Two patients (5%) developed hematoma without history of trauma and treated conservatively. One patient (2.5%) had device migration without affection of its function.Group B: 2 patients developed minor wound infection treated conservatively. One patient (2.5%) had severe wound infection ends up with wound dehiscence and device extrusion despite the use of antibiotics and local rotational flaps. Explantation of the device was done for this patient. Hematoma occurred in one patient (2.5%) without history of trauma and treated conservatively. Another one patient (2.5%) developed device migration without impairment of its function.Conclusion: creation of sub pericranial pocket without internal device fixation by nylon materials is an effective and reliable method in cochlear implantation without compromising the patient safety or device performance.Key words: cochlear implantation, non- fixation, sub pericranial pocket
From a large number of bacterial samples collected from different hospital in Iraq in central health laboratory ,only ten isolates were identified primary as Vibrio. A number of morphology and biochemical test were carried out to complete this identification that showed all bacterial isolates were related to Vibrio cholerae .In this study all Vibrio isolates were investigated for Bio typing and the result showed that all (10) isolate were related to (Eltor biotypes) .Also, the susceptibility test towards eight antibiotics were carried out .
Results shows that ciprofloxacin , Norfloxacin, Erythromycin, Ampicillin, ceftriaxone and Amikacin were the most effective
... Show MoreA new simple and sensitive spectrophotometric method for the determination of trace amount of Co(II) in the ethanol absolute solution have been developed. The method is based on the reaction of Co(II) with ethyl cyano(2-methyl carboxylate phenyl azo acetate) (ECA) in acid medium of hydrochloric acid (0.1 M) givining maximum absorbance at ((λmax = 656 nm). Beer's law is obeyed over the concentration range (5-60) (μg / ml) with molar absorptivity of (1.5263 × 103 L mol-1 cm-1) and correlation coefficient (0.9995). The precision (RSD% ˂ 1%). The stoichiometry of complex was confirmed by Job's method which indicated the ratio of metal to reagent is (2:1). The studied effect of interference elements Zn(II), Cu(II), Na(I), K(I), Ca(II) and Mg
... Show MoreBackground: The patient's vital signs must stay stable pre a pulmonary function test since the approach demands the patient to breathe slowly and deeply and exhale quickly. However, events that cause variations in normal vital signs may impact the patient. Many strategies can be utilized to stabilize vital signs, including music treatment. The purpose of this study is to compare the effectiveness of music therapy on the vital signs of client's pre a pulmonary function test. Methods: An experimental design study with an application (pre-test, post-test), to determine the effectiveness of music therapy for clients pre pulmonary function test for 106 clients in Al-Diwaniyah, Al-Shamiya, and Al- Hamza public hospitals In Iraq. Parti
... Show MoreThe uptake of Cd(II) ions from simulated wastewater onto olive pips was modeled using artificial neural network (ANN) which consisted of three layers. Based on 112 batch experiments, the effect of contact time (10-240 min), initial pH (2-6), initial concentration (25-250 mg/l), biosorbent dosage (0.05-2 g/100 ml), agitation speed (0-250 rpm) and temperature (20-60ºC) were studied. The maximum uptake (=92 %) of Cd(II) was achieved at optimum parameters of 60 min, 6, 50 mg/l, 1 g/100 ml, 250 rpm and 25ºC respectively.
Tangent sigmoid and linear transfer functions of ANN for hidden and output layers respectively with 7 neurons were sufficient to present good predictions for cadmium removal efficiency with coefficient of correlatio
... Show MoreIn this paper, a new third kind Chebyshev wavelets operational matrix of derivative is presented, then the operational matrix of derivative is applied for solving optimal control problems using, third kind Chebyshev wavelets expansions. The proposed method consists of reducing the linear system of optimal control problem into a system of algebraic equations, by expanding the state variables, as a series in terms of third kind Chebyshev wavelets with unknown coefficients. Example to illustrate the effectiveness of the method has been presented.
Samarium(III) ions react with (l-2(2-benzoinidazolyl-azo)-2-hydroxy-3-naphthoic acid in basic medium (pH = 8.0) forms a red-orange complex at A.max (550nm). The complex was found to be stable for at least 48 hrs. at the given pH. The apparent molar absorptivity is 7776.77 L.mol-1.Cm-1 and a linear calibration curve is obtained in the range (0.639x 10-5M - 6.350x 10 -5M). The stoichiometry of complex was confirmed by using mole ratio method which indicated that ratio of reagent to metal is 3:1. The effects of the presence of different cations and anions as interferences in the determination of samarium(III) under the given conditions were investigated
Idiomatic expressions in Russian journalism make one important borrowed means for making a dialogue with the receiver's intellect in so far as it has the distinct feature of having clarity and exactness of meaning. The meaning is seen as a shortcut for covering a series of concepts and details so as to arrive at the intended meaning. This is done by stimulating the reader by the use of certain clear idioms. The use of such idioms in a journalistic text is not for a linguistic purpose only, but it is a cultural and social phenomenon reflecting the type of current changes in the society and it aims at discoursing with the reader's mind. This paper is a practi
... Show MoreThe use of Near-Surface Mounted (NSM) Carbon-Fiber-Reinforced Polymer (CFRP) strips is an efficient technology for increasing flexural and shear strength or for repairing damaged Reinforced Concrete (RC) members. This strengthening method is a promising technology. However, the thin layer of concrete covering the NSM-CFRP strips is not adequate to resist heat effect when directly exposed to a fire or at a high temperature. There is clear evidence that the strength and stiffness of CFRPs severely deteriorate at high temperatures. Therefore, in terms of fire resistance, the NSM technique has a significant defect. Thus, it is very important to develop a set of efficient fire protection systems to overcome these disadvantages. This pape
... Show More