ABSTRACTBackground: cochlear implants are electronic devices that convert sound energy into electrical signals to stimulate ganglion cells and cochlear nerve fibers. These devices are indicated for patients with severe to profound sensorineural hearing losses who receive little or no benefit from hearing aids. The implant basically takes over the function of the cochlear hair cells. The implant consists of external components (microphone, speech processor and transmitting coil) and internal components (receiver stimulator and electrode array). The implant is inserted via a trans mastoid facial recess approach to the round window and scala tympani.Objectives: to determine the effectiveness and safety of non fixation method in cochlear implantation.Methods: a prospective study carried out from September 2009 to September 2012 in Gazi Hariri Hospital. Eighty patients with congenital severe –profound sensorineural hearing loss prepared for cochlear implantation involved in the study and divided into 2 groups. Group A includes 40 patients in whom the internal device was fixed to the skull by nylon suture materials through small burr holes on both sides of the well. Group B includes 40 patients in whom the internal device placed in a tight sub pericranial pocket without nylon fixation to the skull. All patients followed postoperatively for 6 months observing wound healing and local complications (hematoma, infection, wound dehiscence, device extrusion and migration).Results: mean age 4.2 years and male-female ratio was 1.3:1.Group A: 1 patient (2.5%) developed minor wound infection treated conservatively. Three patients (7.5%) developedsevere wound infection with wound breakdown and device extrusion despite the use of antibiotics and local rotational flaps, the device was explanted in those 3 patients. Two patients (5%) developed hematoma without history of trauma and treated conservatively. One patient (2.5%) had device migration without affection of its function.Group B: 2 patients developed minor wound infection treated conservatively. One patient (2.5%) had severe wound infection ends up with wound dehiscence and device extrusion despite the use of antibiotics and local rotational flaps. Explantation of the device was done for this patient. Hematoma occurred in one patient (2.5%) without history of trauma and treated conservatively. Another one patient (2.5%) developed device migration without impairment of its function.Conclusion: creation of sub pericranial pocket without internal device fixation by nylon materials is an effective and reliable method in cochlear implantation without compromising the patient safety or device performance.Key words: cochlear implantation, non- fixation, sub pericranial pocket
In this work, silicon nitride (Si3N4) thin films were deposited on metallic substrates (aluminium and titanium sheets) by the DC reactive sputtering technique using two different silicon targets (n-type and p-type Si wafers) as well as two Ar:N2 gas mixing ratios (50:50 and 70:30). The electrical conductivity of the metallic (aluminium and titanium) substrates was measured before and after the deposition of silicon nitride thin films on both surfaces of the substrates. The results obtained from this work showed that the deposited films, in general, reduced the electrical conductivity of the substrates, and the thin films prepared from n-type silicon targets using a 50:50 mixing ratio and deposited on both
... Show MoreIn this paper, chip and powder copper are used as reinforcing phase in polyester matrix to form composites. Mechanical properties such as flexural strength and impact test of polymer reinforcement copper (powder and chip) were done, the maximum flexural strength for the polymer reinforcement with copper (powder and chip) are (85.13 Mpa) and (50.08 Mpa) respectively was obtained, while the maximum observation energy of the impact test for the polymer reinforcement with copper (powder and chip) are (0.85 J) and (0.4 J) respectively
In this research, the mechanism of cracks propagation for epoxy/ chopped carbon fibers composites have been investigated .Carbon fibers (5%, 10%, 15%, and 20%) by weight were used to reinforce epoxy resin. Bending test was carried out to evaluate the flexural strength in order to explain the mechanism of cracks propagation. It was found that, the flexural strength will increase with increasing the percentage weight for carbon fibers. At low stresses, the cracks will state at the lower surface for the specimen. Increasing the stresses will accelerate the speed of cracks until fracture accorded .The path of cracks is changed according to the distributions of carbon fibers
In current study, the dye from flowers petals of Strelitzia reginae used for the first time to prepare natural photosensitizer for DSSC fabrication. Among five different solvents used to extract the natural dye from S. reginae flowers, the ethanol extract of anthocyanin dye revealed higher absorption spectrum of 0.757a.u. at wavelength of 454nm. A major effect of temperature was studied to increase the extraction yield. The results show that the optimal temperature was 70 °C and there was a sharp decrease of dye concentration from 0.827 at temperature of 70 °C to 0.521 at temperature of 90°C. The extract solution of flowers of S. reginae showed higher concentration in acidic media, especially at pH 4 (0.902). The
... Show MoreAbstract:
The research sought to identify the crises that occurred during the research period and their reflection on the performance of the hotel Research sample as well as to identify the reality of auditing the hotel Research sample and the preparation of a performance audit program can be adopted in auditing the performance of hotels in light of crises, and the problem of the research lies in the lack of a program to audit the performance of hotels that takes into account the crises experienced by the hotel sector, The research was based on solving its problems on three hypotheses, the first is that the performance audit in light of the Covid-19 pand
... Show MoreThis study investigates the implementation of Taguchi design in the estimation of minimum corrosion rate of mild-steel in cooling tower that uses saline solution of different concentration. The experiments were set on the basis of Taguchi’s L16 orthogonal array. The runs were carried out under different condition such as inlet concentration of saline solution, temperature, and flowrate. The Signal-to- Noise ratio and ANOVA analysis were used to define the impact of cooling tower working conditions on the corrosion rate. A regression had been modelled and optimized to identify the optimum level for the working parameters that had been founded to be 13%NaCl, 35ᴼC, and 1 l/min. Also a confirmation run to establish the p
... Show MoreThe current research aims to test the effect of knowledge sharing in its dimensions represented by(individual dimension, organizational dimension, and technological dimension), In reducing the strategic Anxiety of Iraqi Airways, In view of the importance of the two variables for the company from the perspective of society and the sample resulting from directing various organizational phenomena to reduce its strategic Anxiety, As a goal, it should be viewed from multifaceted perspectives(uncertainty, relational disorder, competitive disorder, resource depletion), And it was embodied by choosing the descriptive, exploratory approach, as it is the most appropriate in that aspect, so that the research questionnaire is one of solid scientific
... Show MoreIn this work Laser wireless video communication system using intensity modualtion direct
detection IM/DD over a 1 km range between transmitter and receiver is experimentally investigated and
demonstrated. Beam expander and beam collimeter were implemented to collimete laser beam at the
transmitter and focus this beam at the receiver respectively. The results show that IM/DD communication
sysatem using laser diode is quite attractive for transmitting video signal. In this work signal to noise
ratio (S/N) higher than 20 dB is achieved in this work.