Background: A review of articles of method in treating compound phalangeal fractures by using mini-external fixator, elaborating the anatomy, mechanics, modalities of treatment, and complications of these types of fractures. Also, it compares between different studies regarding the functional results and final outcome. External fixation of phalangeal fractures is a good method for osteo synthesis in certain situations. The simplicity of the surgical procedure and the minimal disruption of the normal bone architecture also make it appealing.Objectives: Evaluating the functional results of the use of mini-external fixator for the treatment of compound fractures of phalangeal bones of the hand.Method: Our study consists of 15 patients, 12 were male and 3 was female, treated with external fixator for sever open hand fractures at Al-Kindy teaching hospital during the period from June 2011 – June 2013, using 2 K-wires bonded by IV needle cover, or 2 K-wires bonded by bone cement.Results: In comparison between different studies, external fixation offers several advantages. It allows preservation of the bone architecture, union of the fracture, facilitatinghealing of the disrupted area, and good functional results. External fixation is versatile, adapting to a wide range of clinical situations. This method of fixation provides good stability and adequate control of comminuted fractures, allowing not only anatomic restoration but also early active motion.Conclusion: External fixators are appropriate in cases of open, comminuted, unstable fractures. Other appropriate settings for external fixation include temporal management of fractures and length preservation of a functional digit
The importance of the current research lies in the importance of teaching competencies and the ability of the teacher to deal and success in his educational career. The research aimed to identify the degree of teaching competencies according to Hermann model of physical education teachers in Baghdad governorate. The descriptive method using the survey method was used on a randomly selected sample of 462 teachers and 314 school principals. After the completion of the survey, the Hermann scale forms were distributed to the teachers. The forms of the teaching competency scale were distributed to their school principals as the direct supervisors of the teachers' evaluation. After completing the survey, the results of each scale were classified
... Show MoreThis paper is focused on orthogonal function approximation technique FAT-based adaptive backstepping control of a geared DC motor coupled with a rotational mechanical component. It is assumed that all parameters of the actuator are unknown including the torque-current constant (i.e., unknown input coefficient) and hence a control system with three motor control modes is proposed: 1) motor torque control mode, 2) motor current control mode, and 3) motor voltage control mode. The proposed control algorithm is a powerful tool to control a dynamic system with an unknown input coefficient. Each uncertain parameter/term is represented by a linear combination of weighting and orthogonal basis function vectors. Chebyshev polynomial is used
... Show MoreDue to the importance of the extraction process in many engineering and medical industries, in addition to great interest in medicinal plants, in this research, microwave-assisted extraction has been applied to extract some active compounds from Rosmarinus officinalis leaves. The optimal extraction conditions were then determined by calculating the ratio and extraction efficiency. The process has also been described through kinetic study by applying five kinetic models, the Hyperbolic diffusion model, Power low model, the First order reaction model, Elovich's model, and Fick's second law diffusion model and determining their compatibility with the studies operation, and determining the kinetic constants for each model. The result
... Show MoreBackground: The purpose of this study was to evaluate the effect of in vitro long-term simulation of oral conditions on the bond strength of PEEK CAD/CAM lingual retainers.
Material and methods: The sample consisted of 12 PEEK CAD/CAM retainers each composed of 2 centrally perforated 3x4mm pads joined by a connector. They were treated by 98% sulfuric acid for 1 minute and then conditioned with Single Bond Universal and bonded to the lingual surface of premolar teeth by 3M Transbond TM System. Half of the retainers were artificially aged using a 30-day water storage and 5000 thermocycling protocol before bond strength testing to compare with the non-aged specimens.
Results: The artificially aged retainers showed a marginally
... Show MoreIn the current analysis, the effects of circumferential scratches along the inner surface of a 170ᵒ -arc partial journal bearing has been numerically investigated. Their impact on the thermo-elasto-hydrodynamic performance characteristics, including maximum pressure, temperature, deformation, and stress, has been examined thoroughly. The ANSYS Fluent CFD commercial code was employed to tackle the iterative solution of flow and heat transfer patterns in the fluid film domain. They are then applied to the ANSYS Static Structure solver to compute the deformation and stress resulted in the solid bearing zone. A wide range of operating conditions has been considered, including the eccentricity ratio ( ) and scratch depth (
... Show More