Pressure ulcer (now called Pressure injury) happens when the bony prominence like the sacrum exposes to pressure for a long period and also can cause soft tissue injury. In order to prevent and cure pressure-induced wounds, continuous and attentive repositioning is necessary. Wound management begins with the identification and aggressive management of the modifiable factors, such as positioning, incontinence, spasticity, diet, devices, and medical comorbidity, which contribute to pressure injury formation. Initial interventions include washing, cleaning, and maintaining the surfaces of the wound. In certain cases, it may be sufficient to debride the non-viable or contaminated tissue; however, operational care in more severe cases or to encourage patient satisfaction may be necessary. Our patient is a 50-year-old overweighted man, nonsmoker, and confined to a wheelchair presented with a 20*20*8 stages 4 ulcers in the sacral area after multiple failed bedside debridement. When we use the fasciocutaneous we should consider the depth of the wound and fill dead space. Here we the local situation in Palestine as those patients are usually neglected and their management is restricted to bedside debridement, with no experience in flap reconstruction operations which would dramatically improve patients’ lives. We believe that further awareness is demanded for such procedures.
Foreign trade is very important in global economies because of its impact on the sustainability of economic growth by stimulating economic activity, creating jobs and expanding production . On the other side , this policy is a major obstacle to many developing countries and the reason is due to the nature of the economies of those countries because they rely mostly on one or a few economic resources, which makes them rely mostly on exports to that resource while they import most of the needs of their local market Which makes them in a spiral of underdevelopment , dependence and economic exposure, which requires them to break that cycle and the launch of economic development Perhaps one of the most important means to a
... Show MoreLow-pressure capacitively coupled RF discharge Ar plasma has been studied using Langmuir probe. The electron temperature, electron density and Debay length were calculated under different pressures and electrode gap. In this work the RF Langmuir probe is designed using 4MHz filter as compensation circuit and I-V probe characteristic have been investigated. The pressure varied from 0.07 mbar to 0.1 mbar while electrode gap varied from 2-5 cm. The plasma was generated using power supply at 4MHz frequency with power 300 W. The flowmeter is used to control Argon gas flow in the range of 600 standard cubic centimeters per minute (sccm). The electron temperature drops slowly with pressure and it's gradually decreased when expanding the electro
... Show MoreAluminum plasma was generated by the irradiation of the target
with Nd: YAG laser operated at a wavelength of 1064 nm. The
effect of laser power density and the working pressure on spectral
lines generating by laser ablation, were detected by using optical
spectroscopy. The electron density was measured using the Stark
broadening of aluminum lines and the electron temperature by
Boltzmann plot method it is one of the methods that are used. The
electron temperature Te, electron density ne, plasma frequency
and Debye length increased with increasing the laser peak
power. The electron temperature decrease with increasing gas
pressure.
A variety of single-engine driven files and inematics have been introduced to improve the clinical performance of NiTi rotary files. The purpose of this in vitro study was to measure and compare the incidence of dentinal defects after root canal preparation with different single file systems.
This work is concerned with a two stages four beds adsorption chiller utilizing activated carbon-methanol adsorption pair that operates on six separated processes. The four beds that act as thermal compressors are powered by a low grade thermal energy in the form of hot water at a temperature range of 65 to 83 °C. As well as, the water pumps and control cycle consume insignificant electrical power. This adsorption chiller consists of three water cycles. The first water cycle is the driven hot water cycle. The second cycle is the cold water cycle to cool the carbon, which adsorbs the methanol. Finally, the chilled water cycle that is used to overcome the building load. The theoretical results showed that average cycle cooling power
... Show More