Background: Prolapsed intervertebral disc is an important and common cause of low backache. MRI has now become universally accepted investigation for prolapsed intervertebral disc. We, however, regularly come across situations, when MRI shows diffuse disc bulges, even at multiple levels, which cannot be correlated clinically and when such cases are operated, no significant disc prolapse is found resulting in negative exploration.Objective: To evaluate the role of M.R.I. finding not only for diagnosis of disc herniation at lumbar region but also for localization the level of herniationMethods: A prospective study on seventy five symptomatic low backache and MRI confirmed prolapsed intervertebral disc patients at lumbo-sacral region were operated on, all of the cases required excision of disc through posterior approach in knee elbow position. The time between MRI taken and surgery was two weeks, from which the data were taken in a questioner forma which include name , age ,gender , occupation , chief complaint , duration, MRI findings and intra operative finding , from June 2011 to October 2013 at Al- Kindy teaching hospital .Results: In our study 75 patients were diagnosed by clinical examination and MRI finding to have disc herniation at lumbar region . The female more than male( 36 females , 12 males) and the ratio was 5-1, the accuracy of MRI against intra operative finding in deciding the provisional diagnosis as disc herniation was 68% .The commonest site was L4-5 disc herniation 43 patients (57.3 % ) , and L5-S1 prolapse is the next common disc herniation level 27 patient (36 % ) , L3-L4 disc herniation was two cases (2.7 %) and L4-L5 ,L5-S1 disc herniation was 3 cases (4% ).Conclusion: The most common level was L4-5 followed by L5S1.The MRI is more accurate in diagnosis of the lumbo-sacral disc herniation and its level in single one is more than multiple levels.Keywords: Disc herniation, MRI, Surgery, posterior approachAl
Objective: To compare the radiological and functional outcomes of patients of Comminuted intraarticular distal radius fractures treated with or without bone marrow injection along with external fixator ligamentotaxis. Methodology: This prospective comparative study on 41 patients with comminuted intra-articular lower end radius fractures distributed patients randomly into two groups depending on whether an aspirate of bone marrow was injected at the fracture site two weeks after fracture management with external fixation ligamentotaxis. Results: The mean age was 35.8 years, with male predominance. The radiological parameters (radial height, radial inclination, and volar tilt) at the 6th month follow up were lower in the group who did not re
... Show MoreFrictional heat is generated when the clutch starts to engag. As a result of this operation the surface temperature is increased rapidly due to the difference in speed between the driving and driven parts. The influence of the thickness of frictional facing on the distribution of the contact pressure of the multi-disc clutches has been investigated using a numerical approach (the finite element method). The analysis of contact problem has been carried out for a multiple disc dry clutch (piston, clutch discs, separators and pressure plate). The results present the distribution of the contact pressure on all tShe surfaces of friction discs that existed in the friction clutch system. Axisymmetric finite element models have been developed to ac
... Show MoreManganese-zinc ferrite MnxZn1-xFe2O4 (MnZnF) powder was prepared using the sol-gel method. The morphological, structural, and magnetic properties of MnZnF powder were studied using X-ray diffraction (XRD), atomic force microscopy (AFM), energy dispersive X-ray (EDX), field emission-scanning electron microscopes (FE-SEM), and vibrating sample magnetometers (VSM). The XRD results showed that the MnxZn1-xFe2O4 that was formed had a trigonal crystalline structure. AFM results showed that the average diameter of Manganese-Zinc Ferrite is 55.35 nm, indicating that the sample has a nanostructure dimension. The EDX spectrum revealed the presence of transition metals (Mn, Fe, Zn, and O) in Mang
... Show MoreIn this work, a magnetic switch was prepared using two typesof ferrofluid materials, the pure ferrofluid and ferrofluid doped with copper nanoparticles (10 nm). The critical magnetic field (Hc) and the state of magnetic saturation (Hs) were studied using three types of laser sources. The main parameters of the magnetic switch measured using pure ferrofluid and He-Ne Laser source were Hc(0.5 mv, 0.4 G), Hs (8.5 mv, 3 G). For the ferrofluid doped with copper nanoparticles were Hc (1 mv, 4 G), Hs (15 mv, 9.6 G), Using green semiconductor laser for the Pure ferrofluid were Hc (0.5 mv, 0.3 G) Hs (15 mv, 2.9 G). While the ferrofluid doped with copper nanoparticles were Hc (0.5 mv, 1 G), Hs (12 mv, 2.8 G) and by using the violet semiconductor l
... Show MoreIn this research we study the effect of UV radiation on pure PC samples and doped samples with plasticizer (DOP) for different exposure times (6, 12, 18, 24h). The study have been made on the change in the IR spectra causes by the UV radiation on both kinds of samples, besides the morphology changes were also studied by the optical microscope. From the results we conclude that the increasing of exposure causes the elaboration of CO2 and C2 gases.