Preferred Language
Articles
/
jkmc-393
Magnetic resonance imaging findings of knee injury
...Show More Authors

Background: Since its introduction to musculoskeletal imaging in the early 1980, magnetic resonance imaging (MRI) has revolutionized diagnostic imaging of the knee. It is therefore become the examination of choice in the evaluation of internal joint structures of the knee like menisci, cruciate ligaments, and articular cartilage.Objectives: to describe the MRI finding in various knee injuries.Patients and methods: A cross sectional study was done on 130 patients with history of knee injury in MRI unit at institute of radiology and al-Shaheed Ghazi Al-Hariri Hospital in medical city complex - Baghdad, from October 2011 to February 2013 includes 103 men, 27 women; the mean age was 33.86 years. MR imaging studies of the knee performed using a 1.5 T MR system. The sequences included coronal and sagittal PD, sagittal T2 FSE, fat suppressed T2 FSE, STIR axial and coronal. Knee MR studies were obtained to evaluate ligament, menisci, articular surface and bone pathologies of knee injuries.Results: MR images were normal in 15 patients; it was positive for meniscal tears in 59 patients and maximum involvement was in the medial meniscus and the posteriorhorn. These tears were classified into grade 1 (28.8%), grade 2 (11.5%), grade 3 (53.9%) and grade 4 (5.8%). Ligament tears were seen in 70 patients. Secondary signs associated with ligament tears were also assessed.Conclusions: MRI is an accurate, non-invasive technique for examination of the soft tissues and osseous structures of the knee. It has great capability in diagnosing meniscal tears and classifying them into grades and types, which would avoid unnecessary arthroscopic examination. It is a very good modality to diagnose complete tears of the anterior cruciate ligament (ACL).maging, meniscus

View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Nov 29 2019
Journal Name
Iraqi Journal Of Physics
Acetic acid concentration estimation using plastic optical fiber sensor based surface Plasmon resonance
...Show More Authors

Optical fiber chemical sensor based surface Plasmon resonance for sensing and measuring the refractive index and concentration for Acetic acid is designed and implemented during this work. Optical grade plastic optical fibers with a diameter of 1000μm were used with a diameter core of 980μm and a cladding of 20μm, where the sensor is fabricated by a small part (10mm) of optical fiber in the middle is embedded in a resin block and then the polishing process is done, after that it is deposited with about (40nm) thickness of gold metal and the Acetic acid is placed on the sensing probe.

View Publication Preview PDF
Crossref (9)
Crossref
Publication Date
Sun Jun 02 2013
Journal Name
Baghdad Science Journal
Computational Optimization of the Radial and Spiral Distortion Aberration Coefficients of Magnetic Deflector
...Show More Authors

Abstract:The optimum design of the magnetic deflector with the lowest values of the radial and spiral distortion aberration coefficients was computed. The optimized calculations were made using three models, Glaser bell-shaped, Grivet-lenz and exponential models. By using the optimum axial field distribution, the pole pieces shape which gave rise to those field distributions was found by using the reconstruction method. The calculations show that the results of the three models coincide at the lower values of the excitation parameter. In general the Glaser- bell shaped model gives the optimum results at the whole range of the excitation parameter under investigation.The negative values of the spiral distortion aberration coefficient appears

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jun 01 2023
Journal Name
2023 Ieee 36th International Symposium On Computer-based Medical Systems (cbms)
Toward a Minimal sEMG Setup for Knee and Ankle Kinematic Estimation during Gait
...Show More Authors

View Publication
Scopus (4)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Fri Dec 01 2023
Journal Name
Iraqi Journal Of Physics
Structural and Magnetic Properties of MnxZn1-xFe2O4 Prepared via Sol-Gel Method
...Show More Authors

      Manganese-zinc ferrite MnxZn1-xFe2O4 (MnZnF) powder was prepared using the sol-gel method. The morphological, structural, and magnetic properties of MnZnF powder were studied using X-ray diffraction (XRD), atomic force microscopy (AFM), energy dispersive X-ray (EDX), field emission-scanning electron microscopes (FE-SEM), and vibrating sample magnetometers (VSM). The XRD results showed that the MnxZn1-xFe2O4 that was formed had a trigonal crystalline structure. AFM results showed that the average diameter of Manganese-Zinc Ferrite is 55.35 nm, indicating that the sample has a nanostructure dimension. The EDX spectrum revealed the presence of transition metals (Mn, Fe, Zn, and O) in Mang

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Mar 03 2013
Journal Name
Baghdad Science Journal
Effect of Magnetic Water Treatment on Prevention of CaCO3 Scales
...Show More Authors

Permanent magnets of different intensities were used to investigate the effect of a magnetic field in the process of preventing deposits of calcium carbonate. The magnets were fixed on the water line from the tap outside. Then heating a sample of this water in flasks and measuring the amount of sediment in a manner weighted differences. These experiments comprise to the change of the velocity of water flow, which amounted to (0.5, 0.75, 1) m/sec through the magnetic fields that are of magnetic strength (2200, 6000, 9250, 11000) Gauss, and conduct measurements, tests and compare them with those obtained from the use of ordinary water.The results showed the effectiveness of magnetic treatment in reducing the rate of deposition of calcium carb

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Nov 10 2025
Journal Name
Journal Of Engineering
Technological Analysis of Flat Surface Conditions by Magnetic Abrasive Finishing Method (MAF)
...Show More Authors

This study introduced the effect of using magnetic abrasive finishing method (MAF) for finishing flat surfaces. The results of experiment allow considering the MAF method as a perspective for finishing flat surfaces, forming optimum physical mechanical properties of surfaces layer, removing the defective layers and decreasing the height of micro irregularities. Study the characteristics which permit judgment parameters of surface quality after MAF method then comparative with grinding

View Publication
Publication Date
Mon Mar 13 2017
Journal Name
Journal Of Baghdad College Of Dentistry
The Effect Of Treatment Protocol and Implant Dimensions on Primary Stability Utilizing Resonance Frequency Analysis
...Show More Authors

ABSTRACT Background: According to Branemark’s protocol, the waiting period between tooth extraction and implant placement is 6–8 months; this is the late placement technique. Achieving and maintaining implant stability are prerequisites for a dental implant to be successful. Resonance Frequency Analysis (RFA) is a noninvasive diagnostic method that measures implant stability. The aim of this study was to investigate the influence of treatment protocol and implant dimensions on primary implant stability utilizing RFA. Materials and methods: This study included 63 Iraqi patients (37 male, 26 female; ranging 22-66 years). According to treatment protocol, the sample was divided into 2 groups; A (delayed) & B (immediate). Dental im

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Oct 31 2018
Journal Name
Al-kindy College Medical Journal
Efficacy Of Hyaluronic Acid And Corticosteroid Intra-Articular Injection In Knee Joint With Primary Osteoarthritis
...Show More Authors

Background: Osteoarthritis OA is the most common joint disorder in the world. Injection of high molecular weight hyaluronic acid intra-articular with steroid is a one of the used therapeutic option for patients with (OA)knee.

Objectives: Objective of this study was the evaluation the efficacy, safety, pluse duration of action of viscosupplementation of the  HMWHA( high molecular weight hyluranic acid ).

Type of the study: Cross-sectional study.

Methods: From 81 patients with sever knee pain due to OA (grades 3–4) were recruited from Al-Yarmouk teaching hospital  & a private clinic during the period from January 2014 till July 2016.

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Mar 30 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
The Role of Chloroquine Phosphate on Acute Phase Reactant Proteins in Patients with Knee Osteoarthritis
...Show More Authors

The acute phase response is a major pathophysiologic phenomenon that accompanies inflammation whether acute or chronic. Complement (C3 and C4) and C - reactive protein (CRP) are positive acute phase proteins (+ ve APPs ). Their production takes place in hepatocyte and the blood concentration of these parameters are increased in osteoarthritis (OA). Chloroquine (CQ) is a diprotic weak base traditionally used to treat malaria. Recently the phosphate salt of CQ is used to decrease this type of (+ve APPs) . In this study,  patients who suffered from knee osteoarthritis (KOA) are treated with oral dosage form of chloroquine phosphate (CQP) for one month, twice daily. Our results demonstrate that CQP improves the patient status by decreas

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Jun 20 2023
Journal Name
Baghdad Science Journal
Hemato-Serological Findings as Early signals in Nile Tilapia Oreochromis niloticus Treated with Benzalkonium Chloride
...Show More Authors

To evaluate the toxicity of benzalkonium chloride in aquaculture, the hemato-serological indices of Nile tilapia Oreochromis niloticus are used as biomarkers. Following exposure to three concentrations of benzalkonium chloride BAC 0.1, 0.25, 0.50, and 1 mg/l (BAC1,2,3 and 4) in aquaria for two durations 21 and 42 days, the microbiological assay in fish aquaria, in addition to blood parameters were assessed. Except for the mean difference between BAC2 and BAC3 (P > 0.05) at 42 days, the mean values of the bacterial counts revealed a significant difference between all compared groups (0.05 ≥ P ≤ 0.01). Following exposure to the lower concentrations of BAC (1, 2 and 3), the main blood parameters of Oreochromis niloticus namely red bl

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (2)
Scopus Crossref