Background: The majorities of statin-treated patients, in whom low-density lipoprotein cholesterol (LDL-C) targets have been achieved, have had recurrent cardiovascular events (CVE) with an absolute rate remain even higher among patients with disorders of insulin resistance, metabolic syndrome (MetS) and type2 diabetes mellitus (T2DM) as compared to patients devoid of these conditions.Objectives: Provide updated key messages of lipid and lipoprotein abnormalities as indicator for cardiovascular disease (CVD) risk in patients with T2DM and obesity, as well as the current evidence-based treatment targets and interventions to reduce this risk.Key messages: The Residual Risk Reduction Initiative (R3I) emphasized atherogenic dyslipidemia (AD) as the chief modifiable contributor to residual cardiovascular risk, especially in conditions associated with insulin-resistant,and call to improve awareness and clinical management.The probable benefit of residual CVD risk reductionsuggests a role for treatment of persistently high TGconcentration even in statin – treated patients, with TG lowering agents including fibrates, niacin, omega polyunsaturatedfatty acids, and other non statin treatment.Therapeutic lifestyle changes including; medically assistedweight loss, physical activity, and dietary changes, as well as improvement of glycemic control should be an adjunct to lipid-lowering pharmacological therapies. Therapy should be concomitantly assessed for treatment tolerance and adequacy with focused laboratory evaluations and patient follow-up. Therapy should be boosted to attain goals according to risk level, and that even more intensive therapy might be warranted in patients with CVD history.
Drilling fluid loss during drilling operation is undesirable, expensive and potentially hazardous problem.
Nasiriyah oil field is one of the Iraqi oil field that suffer from lost circulation problem. It is known that Dammam, um-Radoma, Tayarat, Shiranish and Hartha are the detecting layers of loss circulation problem. Different type of loss circulation materials (LCMs) ranging from granular, flakes and fibrous were used previously to treat this problem.
This study presents the application of rice as a lost circulation material that used to mitigate and stop the loss problem when partial or total losses occurred.
The experim
... Show MoreThe ability of using aluminum filings which is locally solid waste was tested as a mono media in gravity rapid filter. The present study was conducted to evaluate the effect of variation of influent water turbidity (10, 20and 30 NTU); flow rate(30, 40, and 60 l/hr) and bed height (30and60)cm on the performance of aluminum filings filter media for 5 hours run time and compare it with the conventional sand filter. The results indicated that aluminum filings filter showed better performance than sand filter in the removal of turbidity and in the reduction of head loss. Results showed that the statistical model developed by the multiple linear regression was proved to be
valid, and it could be used to predict head loss in aluminum filings
The reaction of 2-amino-benzothiazole with bis [O,O-2,3,O,O – 5,6 – (chloro(carboxylic) methiylidene) ] – L – ascorbic acid (L-AsCl2) gave new product 3-(Benzo[d]Thaizole-2-Yl) – 9-Oxo-6,7,7a,9-Tertrahydro-2H-2,10:4,7-Diepoxyfuro [3,2-f][1,5,3] Dioxazonine – 2,4 (3H) – Dicarboxylic Acid, Hydro-chloride (L-as-am)), which has been insulated and identified by (C, H, N) elemental microanalysis (Ft-IR),(U.v–vis), mass spectroscopy and H-NMR techniques. The (L-as am) ligand complexes were obtained by the reaction of (L-as-am) with [M(II) = Co,Ni,Cu, and Zn] metal ions. The synthesized complexes are characterized by Uv–Visible (Ft –IR), mass spectroscopy molar ratio, molar conductivity, and Magnetic susceptibility techniques. (
... Show MoreThe current work concerns preparing cobalt manganese ferrite (Co0.2Mn0.8Fe2O4) and decorating it with polyaniline (PAni) for supercapacitor applications. The X-ray diffraction findings (XRD) manifested a broad peak of PAni and a cubic structure of cobalt manganese ferrite with crystal sizes between 21 nm. The pictures were taken with a field emission scanning electron microscope (FE-SEM), which evidenced that the PAni has nanofibers (NFs) structures, grain size 33 – 55 nm, according to the method of preparation, where the hydrothermal method was used. The magnetic measurements (VSM) that were conducted at room temperature showed that the samples had definite magnetic properties. Additionally, it was noted that the saturation magnetizatio
... Show MoreAbstract:
In light of the development in the banking environment and the increasing reliance on electronic systems in providing banking services and due to the intense competition witnessed by the banking sector, the need has emerged to apply the comprehensive electronic banking system, which works on the Internet in providing new and diverse banking services regardless of time and place by linking all branches to one central database, and despite the advantages achieved from the application of the comprehensive system, there is a set of risks that accompany the use of that system, What requires the auditors to develop the audit method in line with the size of the development in the
... Show MoreSuperconducting compound Bi2Sr2-xYxCa2Cu3O10+δ were Synthesized by method of solid state reaction, at 1033 K for 160 hours temperature of the sintering at normal atmospheric pressure where substitutions Yttrium oxide with Strontium. When Y2O3 concentration (0.0, 0.1, 0.2, 0.3, 0.4 and 0.5). All specimens of Bi2Sr2Ca2Cu3O10+δ superconducting compounds were examined. The resistivity of electrical was checked by the four point probe technique, It was found th
six specimens of the Hg0.5Pb0.5Ba2Ca2Cu3-y
Non-thermal argon plasma needle at atmospheric pressure was
constructed. The experimental setup was based on a simple and low
cost electric component that generates a sufficiently high electric
field at the electrodes to ionize the argon gas which flow at
atmospheric pressure. A high AC power supply was used with 1.1
kV and 19.57 kHz. Non-thermal Argon plasma used on blood
samples to show the ability of non-thermal plasma to promote blood
coagulation. Three tests have been done to show the ability of plasma
to coagulate both normal and anti-coagulant blood. Each blood
sample has been treated for varying time from 20sec. to 180sec. at
different distances. The results of the current study showed that the
co