Preferred Language
Articles
/
jkmc-37
Low Back Pain and Obesity (Review Article)
...Show More Authors

Low back pain a major causes of morbidity throughout the world and it is a most debilitating condition ,and can lead to decreased physical function ,compromised quality of life, and psychological distress.

Obesity is nowadays a pandemic condition. Obese subjects are commonly characterized by musculoskeletal disorders and particularly by non-specific LBP. However, the relationship between obesity and LBP remain to date unsupported by objective measurements of mechanical behavior of spine and it is morphology in obese subjects.                                    

Key words: obesity, low back pain,

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Mar 31 2018
Journal Name
Journal Of Engineering
Seismic Response of Nonseismically Designed Reinforced Concrete Low Rise Buildings
...Show More Authors

In this paper, the time-history responses of a square plan two-story reinforced concrete prototype building, considering the elastic and inelastic behavior of the materials, were studied numerically. ABAQUS software was used in three-dimensional (3D) nonlinear dynamic analysis to predict the inelastic response of the buildings. Concrete Damage Plasticity Model (CDPM) has been used to model the inelastic behavior of the reinforced concrete building under seismic excitation. The input data included geometric information, material properties, and the ground motion. The building structure was designed only for gravity load according to ACI 318 with

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Aug 01 2018
Mixed Linearity Improvement Techniques for Ultra-wideband Low Noise Amplifier
...Show More Authors

<span>We present the linearization of an ultra-wideband low noise amplifier (UWB-LNA) operating from 2GHz to 11GHz through combining two linearization methods. The used linearization techniques are the combination of post-distortion cancellation and derivative-superposition linearization methods. The linearized UWB-LNA shows an improved linearity (IIP3) of +12dBm, a minimum noise figure (NF<sub>min.</sub>) of 3.6dB, input and output insertion losses (S<sub>11</sub> and S<sub>22</sub>)  below -9dB over the entire working bandwidth, midband gain of 6dB at 5.8GHz, and overall circuit power consumption of 24mW supplied from a 1.5V voltage source. Both UWB-LNA and linearized UWB-LNA designs are

... Show More
Scopus (1)
Scopus Crossref
Publication Date
Wed Jun 29 2022
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Measuring Dyes Concentration Using a Low-Cost Visible-Light Spectrophotometer
...Show More Authors

   A low-cost, RGB LED-based visible-light spectrophotometer was designed to measure dyes concentration. Dyes are widely used as indicators or coloring agents in different applications and knowing their concentration is an essential part for many studies. The proposed spectrophotometer provides many functionalities that clones the traditional expensive spectrophotometers for a budged price under $50. It was aimed to provide a versatile tool for instructors and educators to teach their students the fundamental concepts behind spectrophotometry. Malachite green, methyl red, and methyl orange dyes were chosen to be good samples to show the integrity of the proposed spectrophotometer in terms of accuracy, repeatability, and sensitivity as

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Feb 04 2019
Journal Name
Iraqi Journal Of Physics
Diagnostics of low-pressure capacitively coupled RF discharge argon plasma
...Show More Authors

Low-pressure capacitively coupled RF discharge Ar plasma has been studied using Langmuir probe. The electron temperature, electron density and Debay length were calculated under different pressures and electrode gap. In this work the RF Langmuir probe is designed using 4MHz filter as compensation circuit and I-V probe characteristic have been investigated. The pressure varied from 0.07 mbar to 0.1 mbar while electrode gap varied from 2-5 cm. The plasma was generated using power supply at 4MHz frequency with power 300 W. The flowmeter is used to control Argon gas flow in the range of 600 standard cubic centimeters per minute (sccm). The electron temperature drops slowly with pressure and it's gradually decreased when expanding the electro

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Oct 01 2014
Journal Name
2014 44th European Microwave Conference
A low magnetic bias sub-millimetre wave semiconductor junction circulator
...Show More Authors

View Publication
Scopus (2)
Scopus Crossref
Publication Date
Sat Dec 30 2017
Journal Name
Al-khwarizmi Engineering Journal
Design & Implementation of High Switching & Low Phase Noise Frequency Synthesizer
...Show More Authors

This research  describes the design & implementation of frequency synthesizer using single loop Phase lock loop with the following specifications: Frequency range (1.5 – 2.75) GHz,Step size (1 MHz), Switching time 36.4 µs, & phase noise @10 kHz = -92dBc & spurious -100 dBc

  The development in I.C. technology provide the simplicity in the design of frequency synthesizer because it implements the phase frequency detector(PFD) , prescalar &  reference divider in single chip. Therefore our system consists of  a single chip contains (low phase noise PFD, charge pump, prescalar  & reference divider), voltage controlled oscillator , loop filter & reference oscillator. The single chip

... Show More
View Publication Preview PDF
Publication Date
Sun Feb 01 2026
Journal Name
Applied Acoustics
Development of an acoustic vacuum gauge for low-pressure measurement
...Show More Authors

View Publication
Scopus Clarivate Crossref
Publication Date
Mon Aug 26 2024
Journal Name
Jbpml
Studying The Changes in Motility and Morphology on Human sperm after exposure to low doses of x-rays
...Show More Authors

the energy that a radiation source emits as light (photons), electromagnetic waves, or particles is known as radiation. X-ray is one type of ionizing radiation that falls within the electromagnetic wave category of short wavelengths. Because of their short wavelength. X-ray is a type of ionizing radiation that is used in a constantly growing number of diagnostic procedures. X-ray diagnostic imaging has been employed in the medical field for more than a century(Hariyoto et al., 2020). Radiation has advantages for human health, but there is also a risk. the impacts of Radiation on Fertility it is an oligospermia, or a reduction in the number of sperm cells, which is already possible after radiation exposure of 0.15 mGy. It Leads to impede

... Show More
Publication Date
Thu Oct 24 2024
Journal Name
Scientific Reports
Effectiveness of high-frequency vibration, cotton rolls and elastomeric wafers in alleviating debonding pain of orthodontic metal brackets: a randomized clinical trial
...Show More Authors

View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sat Jul 20 2024
Journal Name
Al-rafidain Journal Of Medical Sciences ( Issn 2789-3219 )
Gender Distribution of Coronary Artery Calcium Score and Degree of Stenosis Assessed by Computed Tomography Angiography in Iraqi Patients with Chest Pain
...Show More Authors

Background: Sex variations in coronary artery disease (CAD) are well documented. However, sex differences in coronary artery calcium (CAC) and its role in the detection of coronary artery stenosis remain controversial. Objective: To assess the impact of sex variation on coronary artery calcification and its efficacy in predicting coronary artery stenosis. Methods: This is a cross-sectional observational study including 230 consecutive patients with suspected CAD (120 men and 110 women) referred for coronary computed tomography angiography (CCTA). The study analyzed sex-based differences in the sensitivity and specificity of coronary artery calcification (CAC) for detecting moderate to severe stenosis across various coronary arteries

... Show More
View Publication
Scopus (5)
Crossref (6)
Scopus Crossref