Preferred Language
Articles
/
jkmc-372
Precision of pachymetric measurements with Scheimpflug –Placido disc cornealTopography and comparison of these measurements with ultrasonic pachymetry
...Show More Authors

Back ground: Several devices with different physical bases have been developed for the clinical measurement of corneal thickness, they classified into 4 categories: Scheimpflug photography based, Slit –Scanning topography, optical coherence tomography (OCT) based and ultrasound (US) based.Objective:To evaluatethe precision of the new Scheimpflug –Placido disc corneal topography in measurement of corneal thickness and to compare the measured values with that obtained by US pachymetry.Methods: Setting of this study is Lasik center in Eye Specialty Private Hospital. Baghdad. Iraq.Eyes of healthy subjects were examined with the Sirius topography.3 consecutive measurements of central (CCT)and thinnest (TCT) corneal thicknesses were obtainedand the measurements repeated within 1 week. The within –subject standard deviation (Sw),test-retest repeatability ,coefficient of variation (CoV),and interclass correlation coefficient (ICC) were calculated to evaluate intra session repeatability and intersession reproducibility. For US pachymetry (Tomey-SP 100) only CCT was measured. Comparison ofthe measurements that obtained by the 2 devices done by paired t-test.Results: The topography provides high intrasession repeatability with test-retest and CoV close to 6μm and0.4%, respectively for both CCT and TCT. The inter session reproducibility also high with test-retest and CoV close to 8μm and 0.5%, respectively.ICC was higher than 0.97 for repeatability and reproducibility . Anarrow 95% limit of agreement was found between the pachymetry obtained by topography and US pachymetry measurements.Conclusions :The topography has been used showed high intrasession repeatability and intersession reproducibility of CCT and TCT measurements in healthy eyes .Absence of statistically significant differences suggest that the topography -TCT and the US pachymetry - CCT can be used interchangeably in subject with normal cornea.Financial Disclosure: No financial or proprietary interest in any material or method mentioned.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon May 17 2021
Journal Name
Indian Journal Of Forensic Medicine & Toxicology
The Effect of Exercises with a Proposed Device to Improving Some Bio-Kinematic Variables and the Performance of the Arab Round off Skill on Floor Movement Mat Device of the Artistic Gymnastics for Women
...Show More Authors

The importance of the research lies in preparing exercises using a proposed device to learn the skill of thehuman wheel on a machine rug of ground movements of the artistic gymnastics. As for the research problem:Through the presence of the two researchers as teachers and observers of this sport in the gymnastics hall,they noticed that there is difficulty in the students’ performance of the skill of the round off on the machineof the mat of ground movements, according to the researchers’ opinion, the reason for this is that skillsare taught with the limited availability of assistive devices, as well as the lack of use of these devices inexercises according to biomechanical variables, although they facilitate the learning process

... Show More
View Publication
Crossref
Publication Date
Wed Mar 31 2021
Journal Name
Integrative Systematics: Stuttgart Contributions To Natural History
A confirmed record of the European catfish Silurus glanis L., 1758 (Actinopterygii: Siluriformes: Siluridae) from the southern marshes of Iraq, with a new anatomical set of characters to separate S. glanis and S. triostegus
...Show More Authors

View Publication
Scopus (4)
Crossref (2)
Scopus Crossref
Publication Date
Fri Jul 25 2014
Journal Name
Modern Sport
Analyze study for some biomechanics variables to jump shoot skill from different spots with and without defense to basketball youth players in 3x3
...Show More Authors

The research to knows some biomechanics variables in different spots with and without players in basketball youth players and analysis by using destructive method in surfing study and the research were applied for jump shoot from one of basketball players in ( middle , left , right ) in side zone and out of zone also from three point shoot with and without defense and we depend on successful shoot on analyze .The results and conclusions that center of weight of the player on standby on high and knee angel and hips were more wide also the two angle of wrist , elbow on start of shooting be more wide with defender more than without defender .the maximum high center of weight and shooting angle and ball entrance being less degree with defender

... Show More
View Publication Preview PDF
Publication Date
Sat Jun 01 2024
Journal Name
Case Studies In Chemical And Environmental Engineering
Congo red removal from aqueous solution by electrocoagulation- electro-oxidation combined system with Al and Cu–Mn–Ni nano composite as efficient electrodes
...Show More Authors

Removing Congo red (CR) is critical in wastewater treatment. We introduce a combination of electrocoagulation (EC) and electro-oxidation (EO) to address the elimination of CR. We also discuss the deposition of triple oxides (Cu–Mn–Ni) simultaneously on both anodic and cathodic graphite electrodes at constant current density. These electrodes efficiently worked as anodes in the EC-EO system. The EC-CO combination eliminated around 98 % of the CR dye and about 95 % of the Chemical Oxygen demand (COD), and similar results were obtained with the absence of NaCl. Thus, EC-EO is a promising technique to remove CR in an environmentally friendly pathway.

View Publication
Scopus (8)
Crossref (6)
Scopus Crossref
Publication Date
Thu Feb 03 2022
Journal Name
Open Access Macedonian Journal Of Medical Sciences
Femtosecond Small Incision Lenticular Extraction in comparison to Femtosecond Laser In situ Keratomileusis Regarding Dry Eye Disease
...Show More Authors

 Abstract Objective: Comparison of femtosecond small incision lenticule extraction (FS-SMILE) versus Femtosecond laser Insitu keratomileusis (FS-LASIK) regarding dry eye disease (DED) and corneal sensitivity (CS) after those refractive surgeries. Methods: A comparative prospective study conducted for a period of 2 years; from March 2017 until February, 2019. Enrolled patients were diagnosed with myopia. Fifty patients (100 eyes) were scheduled for bilateral FS-SMILE and the other 50 patients (100 eyes) had been scheduled for bilateral FS-LASIK. Both groups were followed for six months after surgery. The age, gender, and preoperative refraction for both groups were matched. Complete evaluation of dry eye disease had been

... Show More
Crossref
Publication Date
Tue Dec 20 2022
Journal Name
Biomedical And Pharmacology Journal
Phytochemical Comparison Study for Evaluating the Hypolipidemic Effect Between Two Iraqi Pepper Spp in the Rats Model.
...Show More Authors

Hypercholesterolemia is a predominant risk factor for atherosclerosis and cardiovascular disease (CVD). The World Health Organization (WHO), ) recommended reducing the intake of cholesterol and saturated fats. On the other hand, limited evidence is available on the benefits of vegetables in the diet to reduce these risk factors, so this research was conducted to compare the hypolipidemic effect between the extracts of two different types of Iraqi peppers, the fruit of the genus Capsicum traditionally known as red pepper extract (RPE), and Piper nigrum as black pepper extract (BPE), respectively, in different parameters and histology of the liver of the experimental animals. The red pepper was extracted by ethyl acetate, while the black pepp

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (2)
Scopus Crossref
Publication Date
Thu Feb 03 2022
Journal Name
Open Access Macedonian Journal Of Medical Sciences
Femtosecond Small Incision Lenticular Extraction in comparison to Femtosecond Laser In situ Keratomileusis Regarding Dry Eye Disease
...Show More Authors

 Abstract Objective: Comparison of femtosecond small incision lenticule extraction (FS-SMILE) versus Femtosecond laser Insitu keratomileusis (FS-LASIK) regarding dry eye disease (DED) and corneal sensitivity (CS) after those refractive surgeries. Methods: A comparative prospective study conducted for a period of 2 years; from March 2017 until February, 2019. Enrolled patients were diagnosed with myopia. Fifty patients (100 eyes) were scheduled for bilateral FS-SMILE and the other 50 patients (100 eyes) had been scheduled for bilateral FS-LASIK. Both groups were followed for six months after surgery. The age, gender, and preoperative refraction for both groups were matched. Complete evaluation of dry eye disease had been

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Oct 07 2020
Journal Name
Indian Journal Of Forensic Medicine & Toxicology
CA 27-29: A Valuable Marker for Breast Cancer Management in Correlation with CA 15-3
...Show More Authors

View Publication
Scopus (5)
Crossref (2)
Scopus Crossref
Publication Date
Wed Jul 01 2015
Journal Name
Journal Of The Faculty Of The Medicine Baghdad
Do low back pain changes correlate with sagittal lumbar alignment changes after total hip replacement arthroplasty?
...Show More Authors

Abstract Background: The hip joint and lumbar spine are both anatomically and functionally closely related as had shown by many authors. So the abnormality in one area can affect the other e.g. hip joint osteoarthritis can cause lumbar sagittal malalignment and backache. Objectives: is to see if there is significant improvement in backache after total hip replacement? And which degree of backache improvement is associated with significant changes in lumbar lordosis? Methods and patients: a prospective open trial study was performed on 30 patients who had severe hip osteoarthritis and chronic low back pain. Total hip replacement was performed to all patients. Backache and lumbar lordosis were measured by visual analogue scale and Cobb’s a

... Show More
Preview PDF
Publication Date
Fri Aug 13 2021
Journal Name
Journal Européen Des Systèmes Automatisés
Proxy-based sliding mode vibration control with an adaptive approximation compensator for euler-bernoulli smart beams
...Show More Authors

Proxy-based sliding mode control PSMC is an improved version of PID control that combines the features of PID and sliding mode control SMC with continuously dynamic behaviour. However, the stability of the control architecture maybe not well addressed. Consequently, this work is focused on modification of the original version of the proxy-based sliding mode control PSMC by adding an adaptive approximation compensator AAC term for vibration control of an Euler-Bernoulli beam. The role of the AAC term is to compensate for unmodelled dynamics and make the stability proof more easily. The stability of the proposed control algorithm is systematically proved using Lyapunov theory. Multi-modal equation of motion is derived using the Galerkin metho

... Show More
Crossref (2)
Crossref