Preferred Language
Articles
/
jkmc-372
Precision of pachymetric measurements with Scheimpflug –Placido disc cornealTopography and comparison of these measurements with ultrasonic pachymetry
...Show More Authors

Back ground: Several devices with different physical bases have been developed for the clinical measurement of corneal thickness, they classified into 4 categories: Scheimpflug photography based, Slit –Scanning topography, optical coherence tomography (OCT) based and ultrasound (US) based.Objective:To evaluatethe precision of the new Scheimpflug –Placido disc corneal topography in measurement of corneal thickness and to compare the measured values with that obtained by US pachymetry.Methods: Setting of this study is Lasik center in Eye Specialty Private Hospital. Baghdad. Iraq.Eyes of healthy subjects were examined with the Sirius topography.3 consecutive measurements of central (CCT)and thinnest (TCT) corneal thicknesses were obtainedand the measurements repeated within 1 week. The within –subject standard deviation (Sw),test-retest repeatability ,coefficient of variation (CoV),and interclass correlation coefficient (ICC) were calculated to evaluate intra session repeatability and intersession reproducibility. For US pachymetry (Tomey-SP 100) only CCT was measured. Comparison ofthe measurements that obtained by the 2 devices done by paired t-test.Results: The topography provides high intrasession repeatability with test-retest and CoV close to 6μm and0.4%, respectively for both CCT and TCT. The inter session reproducibility also high with test-retest and CoV close to 8μm and 0.5%, respectively.ICC was higher than 0.97 for repeatability and reproducibility . Anarrow 95% limit of agreement was found between the pachymetry obtained by topography and US pachymetry measurements.Conclusions :The topography has been used showed high intrasession repeatability and intersession reproducibility of CCT and TCT measurements in healthy eyes .Absence of statistically significant differences suggest that the topography -TCT and the US pachymetry - CCT can be used interchangeably in subject with normal cornea.Financial Disclosure: No financial or proprietary interest in any material or method mentioned.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Mar 13 2017
Journal Name
Journal Of Baghdad College Of Dentistry
The Effect of Artificial Accelerated Aging on The Color of Ceramic Veneers Cemented With Different Resin Cements (A Comparative In Vitro Study)
...Show More Authors

ABSTRACT Background: Color changes that are detectable to human eye can affect the esthetic appearance of ceramic veneers. The purpose of this study was to evaluate and compare the effect of artificial accelerated aging on the color of ceramic veneers cemented with different resin cements. Materials and Methods: Sixty discs were prepared with 0.5 mm thickness, 30 discs made from IPS e.max press (Ivoclar Vivadent) and 30 discs were made from VITA Enamic (VITA Zahnfabrik). The discs were cemented with three resin cements: Variolink Veneer MV 0 shade (Ivoclar Vivadent), Rely X veneer Translucent shade (3M ESPE) and NX3 Nexus Clear shade (Kerr Corporation) with 0.1 mm thickness. The spectrophotometer Easyshade Advance was used to measure the co

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Wed Mar 23 2022
Journal Name
Journal Of Educational And Psychological Researches
The extent of the social worker’s use of group discussion technique in professional practice with school activity groups in Tubas Governorate schools
...Show More Authors

This study aimed at identifying the extent to which the social worker used the techniques of group discussion in the professional practice with the groups of school activity in the schools of Tubas governorate in light of some variables (gender, years of experience, academic qualification). The analytical descriptive method was used due to its suitability for the objectives of the study.  A questionnaire was designed to collect data that included (30) items, distributed in three areas .The validity and reliability of the tool were verified and then distributed to the study sample.

 

The results of the study showed that the highest averages were in the discussion stage domain, where the pre-discussion stage was m

... Show More
View Publication Preview PDF
Publication Date
Tue Dec 06 2022
Journal Name
Iraqi National Journal Of Nursing Specialties
Quality of Life of Children age from (8- lessthan13) years with Acute Lymphocytic Leukemia Undergoing Chemotherapy at Hematology Center in Medical City
...Show More Authors

Objective (s): To assess the QoL of children age from (8- lessthan13) years with acute lymphocytic leukemia undergoing chemotherapy and to find out the relationship between the QoL of children with acute lymphocytic leukemia and their illness history.

Methodology:  A descriptive study included (40) children with acute lymphocytic leukemia who were ranged between (8 - less than 13 years) at the Hematology Center in Medical City for the period from 4th March 2021 to 1st September 2021. The sample was non-probability (purposive) sample of children (male and female). A questionnaire designed with 2 main parts was used. The first part focused on sociodemographic characterist

... Show More
View Publication Preview PDF
Publication Date
Mon Sep 01 2025
Journal Name
Continence
Does the presence of Fowler's syndrome predicts successful long-term outcome of sacral nerve stimulation in women with non-obstructive urinary retention?
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Mon Apr 17 2023
Journal Name
Day 2 Tue, April 18, 2023
Development of a Multi-Completion Gas and Downhole Water Sink-Assisted Gravity Drainage (MC-DWS-AGD) to Improve Oil Recovery and Reduce Water Cut in Reservoirs with Strong Water Aquifers
...Show More Authors
Abstract<p>Gas and downhole water sink assisted gravity drainage (GDWS-AGD) is a promising gas-based enhanced oil recovery (EOR) process applicable for reservoirs associated with infinite aquifers. However, it can be costly to implement because it typically involves the drilling of multiple vertical gas-injection wells. The drilling and well-completion costs can be substantially reduced by using additional completions for gas injection in the oil production wells through the annulus positioned at the top of the reservoir. Multi-completion-GDWS-AGD (MC-GDWS-AGD) can be configured to include separate completions for gas injection, oil, and water production in individual wells. This study simulates</p> ... Show More
View Publication
Crossref (2)
Crossref
Publication Date
Thu Apr 01 2021
Journal Name
Neuroquantology
Finding Most Stable Isobar for Nuclides with Mass Number (165- 175) against Beta Decay
...Show More Authors

In the beta decay process, a neutron converts into a proton, or vice versa, so the atom in this process changes to a more stable isobar. Bethe-Weizsäcker used a quasi-experimental formula in the present study to find the most stable isobar for isobaric groups of mass nuclides (A=165-175). In a group of isobars, there are two methods of calculating the most stable isobar. The most stable isobar represents the lowest parabola value by calculating the binding energy value (B.E) for each nuclide in this family, and then drawing these binding energy values as a function of the atomic number (Z) in order to obtain the mass parabolas, the second method is by calculating the atomic number value of the most stable isobar (ZA). The results show

... Show More
Publication Date
Sat Mar 01 2025
Journal Name
Acta Marisiensis - Seria Medica
Transcatheter balloon valvuloplasty for children with severe pulmonary valve stenosis: A single-center experience
...Show More Authors
Abstract<p> <bold>Objectives</bold>: this study aim to assess the effectiveness of the Transcatheter balloon valvoplasty (BVP) of severe Pulmonary stenosis (PS) and identify possible complications and predictors for the outcome.</p><p> <bold>Methods</bold>: A retrospective study was conducted at the Iraqi Center of Cardiac Diseases for a 2-year duration in the period from 2021 to the end of 2023; the patients with confirmed severe PS of both genders within the age equal to or less than 18 years were included. For every patient included in the present study, the following data were collected: Demographic data, Echoc</p> ... Show More
View Publication
Scopus (1)
Scopus Crossref
Publication Date
Thu Jun 15 2023
Journal Name
Romanian Neurosurgery
A giant A4-A5 distal anterior cerebral artery aneurysm treated with microsurgical clip reconstruction
...Show More Authors

Background. Aneurysms of the distal anterior cerebral artery (DACA) are uncommon; they often form near the pericallosal-callosomarginal junction and are typically small. To our knowledge, giant DACA aneurysms developing from the more distant parts of the anterior cerebral artery (ACA), A4-5, have been described only once in the literature. Case description. A 66-year-old gentleman reported with a brief loss of consciousness followed by weakness in his right lower leg. The patient was admitted with a Glasgow Coma Score (GCS) of 15. A computed tomography (CT) scan of the head revealed a left hyperdense mass in the frontal parasagittal supracallosal region. Contrast MRI revealed a heterogeneously enhancing mass measuring 35x30x25 mm. C

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Jan 04 2021
Journal Name
Multimedia Tools And Applications
Attention enhancement system for college students with brain biofeedback signals based on virtual reality
...Show More Authors

View Publication
Scopus (5)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Fri Nov 04 2022
Journal Name
Journal Of Optics
Coreless optical fiber for hemoglobin (HB) sensing with bilayer based on surface plasmon resonance
...Show More Authors

In this work, an optical fiber biomedical sensor for detecting the ratio of the hemoglobin in the blood is presented. A surface plasmon resonance (SPR)-based coreless optical fiber was developed and implemented using single- and multi-mode optical fibers. The sensor is also utilized to evaluate refractive indices and concentrations of hemoglobin in blood samples, with 40 nm thickness of (20 nm Au and 20 nm Ag) to increase the sensitivity. It is found in practice that when the sensitive refractive index increases, the resonant wavelength increases due to the decrease in energy.

View Publication Preview PDF
Scopus (6)
Crossref (5)
Scopus Clarivate Crossref