Back ground: Several devices with different physical bases have been developed for the clinical measurement of corneal thickness, they classified into 4 categories: Scheimpflug photography based, Slit –Scanning topography, optical coherence tomography (OCT) based and ultrasound (US) based.Objective:To evaluatethe precision of the new Scheimpflug –Placido disc corneal topography in measurement of corneal thickness and to compare the measured values with that obtained by US pachymetry.Methods: Setting of this study is Lasik center in Eye Specialty Private Hospital. Baghdad. Iraq.Eyes of healthy subjects were examined with the Sirius topography.3 consecutive measurements of central (CCT)and thinnest (TCT) corneal thicknesses were obtainedand the measurements repeated within 1 week. The within –subject standard deviation (Sw),test-retest repeatability ,coefficient of variation (CoV),and interclass correlation coefficient (ICC) were calculated to evaluate intra session repeatability and intersession reproducibility. For US pachymetry (Tomey-SP 100) only CCT was measured. Comparison ofthe measurements that obtained by the 2 devices done by paired t-test.Results: The topography provides high intrasession repeatability with test-retest and CoV close to 6μm and0.4%, respectively for both CCT and TCT. The inter session reproducibility also high with test-retest and CoV close to 8μm and 0.5%, respectively.ICC was higher than 0.97 for repeatability and reproducibility . Anarrow 95% limit of agreement was found between the pachymetry obtained by topography and US pachymetry measurements.Conclusions :The topography has been used showed high intrasession repeatability and intersession reproducibility of CCT and TCT measurements in healthy eyes .Absence of statistically significant differences suggest that the topography -TCT and the US pachymetry - CCT can be used interchangeably in subject with normal cornea.Financial Disclosure: No financial or proprietary interest in any material or method mentioned.
Background: Although mammography is a powerful screening tool in detection of early breast cancer, it is imperfect, particularly for women with dense breast, which have a higher risk to develop cancer and decrease the sensitivity of mammogram, Automated breast ultrasound is a recently introduced ultrasonography technique, developed with the purpose to standardize breast ultrasonography and overcome some limitations of handheld ultrasound, this study aims to evaluate the diagnostic efficacy of Automated breast ultrasound and compare it with handheld ultrasound in the detection and characterization of breast lesions in women with dense breasts. Objectives: To evaluate the diagnostic efficacy of Automated breast ultrasound and compare
... Show MoreA condense study was done to compare between the ordinary estimators. In particular the maximum likelihood estimator and the robust estimator, to estimate the parameters of the mixed model of order one, namely ARMA(1,1) model.
Simulation study was done for a varieties the model. using: small, moderate and large sample sizes, were some new results were obtained. MAPE was used as a statistical criterion for comparison.
Background: Although mammography is a powerful screening tool in detection of early breast cancer, it is imperfect, particularly for women with dense breast, which have a higher risk to develop cancer and decrease the sensitivity of mammogram, Automated breast ultrasound is a recently introduced ultrasonography technique, developed with the purpose to standardize breast ultrasonography and overcome some limitations of handheld ultrasound, this study aims to evaluate the diagnostic efficacy of Automated breast ultrasound and compare it with handheld ultrasound in the detection and characterization of breast lesions in women with dense breasts.
Objectives:<
... Show MoreBackground: Chronic periodontitis (CP) is greatly prevalent condition of inflammatory behavior. Salivary biomarker total antioxidants capacity (T-AOC) status, may be related to both periodontal condition and oral hygiene. Aims of the study: To assess the level of salivary T-AOC of patients with chronic periodontitis in comparison to healthy control and to correlate between the level of this marker with the clinical periodontal parameters (plaque index (PLI), gingival index (GI), bleeding on probing (BOP), probing pocket depth (PPD), and clinical attachment level (CAL)). Materials and Methods: Ninety subjects of males and females with an age ranged between (35-55) years were participated in this study. Participants were divided into two grou
... Show MoreBackground: Optimal root canal retreatment was required safe and efficient removal of filling material from root canal. The aim of this in vitro study was to compare the efficacy of reciprocating and continuous motion of four retreatment systems in removal of root canal filling material. Materials and Methods: Forty distal roots of the mandibular first molars teeth were used in this study, these roots were embedded in cold clear acrylic,roots were instrumented using crown down technique and rotary ProTaper systemize Sx to size F2 ,instrumentation were done with copiousirrigation of 2.5% sodium hypochlorite and 17% buffered solution of EDTA was used as final irrigant followed by distilledwater, roots were obturated with AH26 sealer and Prota
... Show MoreS Khalifa E, N Adil A, AS Mazin M…, 2008
KE Sharquie, AA Noaimi, MM Al-Salih, Saudi Medical Journal, 2008 - Cited by 56
The study aimed to evaluate the level of MMP‑2 in acute myeloid leukemia (AML) patients in comparison with that in remission status, and healthy subjects, and to find its correlation with hematologic parameters. This study included sixty newly diagnosed AML patients. Remission status was assessed after induction chemotherapy. The overall survival (OS) was determined after 6 months. The plasma MMP‑2 level was measured at diagnosis by enzyme immunoassay. Twenty‑eight healthy individuals were recruited as a control group. Plasma MMP‑2 was higher in AML patients than in healthy individuals (P = 0.005). The level of MMP‑2 was much higher in the M5 subtype than in the other subtypes (P = 0.0001). There was no statistically significant d
... Show MoreThe aim of this study is to propose mathematical expressions for estimation of the flexural strength of plain concrete members from ultrasonic pulse velocity (UPV) measurements. More than two hundred pieces of precast concrete kerb units were subjected to a scheduled test program. The tests were divided into two categories; non-destructive ultrasonic and bending or rupture tests. For each precast unit, direct and indirect (surface) ultrasonic pulses were subjected to the concrete media to measure their travel velocities. The results of the tests were monitored in two graphs so that two mathematical relationships can be drawn. Direct pulse velocity versus the flexural strength was given in the first relationship while the second equation des
... Show More