Preferred Language
Articles
/
jkmc-350
Detection of Thrombi in Left Atrial chamber by Transoesophageal Ecchocardiography in patients suffer from Non-rheumatic Atrial Fibrillation
...Show More Authors

Background: Background : Patients with non-rheumatic atrial fibrillation have high risk of thromboembolism especially ischemic stroke usually arising from left atrial appendage .Transoesophageal echocardiography provides useful information for risk stratification in these patients as it detects thrombus in the left atrial or left atrial appendage. Objective : This study was conducted at Al-Kadhimiya Teaching Hospital to assess the prevalence of left atrial chamber thrombi in patients with chronic non-rheumatic atrial fibrillation using transoesophageal echocardiography and its clinical significance as well as to verify the superiority of transoesophageal over transthoracic echocardiography in the detection of these abnormalities. Type of the study: Cross sectional study.Patients and Methods : Forty (40) consecutive patients (11 female and 29 male), at a mean age of 46 ± 9 years (range 28–60) with chronic non-rheumatic Atrial fibrillation were enrolled to this prospective study between March 2006 and December 2006. Tansthoracic and transesophageal two dimensional , M- mode , Doppler, and color- flow echocardiography were obtained with a kretz diagnostic ultrasound system. Results : The prevalence of Left atrium thrombus was 12.5%, 5 patients from the total number which was 40 patients. All of them seen bytransoesophagealechocardiography and non are detected byTansthoracic echocardiography . All the left atrial thrombi were confined to the left atrial appendage (100%). Left atrial spontaneous echo contrast was detected in 10 patients 25% by transoesophageal echocardiography, but was not observed in patient bytransthoracic echocardiography. All the 5 thrombi were found in left atria were significantly associated with spontaneous echo contrast 100% (P-value <0.001), reduced left ventricle ejection fraction (p-value <0.05) , large left atrium diameter ( p-value <0.05) and low LAAV <20 cm/s (p-value <0.001) compared to those without thrombus . Conclusions : The study showed that the prevalence of left atrial thrombus and appendage is not uncommon in patients with non-rheumatic atrial fibrillation and is exclusively seen in patients with left atrial SEC. Low Left ventricle ejection fraction , large Left atrium diameter , and low Left atrial appendages velocity are significantly associated with subsequent thrombus formation , and is more sensitive in the detection of these abnormalities compared with transthoracic echocardiography

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Jan 10 2019
Journal Name
Association Of Arab Universities Journal Of Engineering
Improvement of Earth Canals Constructed on a Gypseous Soil By Cement
...Show More Authors

View Publication
Publication Date
Sun Dec 06 2015
Journal Name
Baghdad Science Journal
Generated and shifted of Ion beams By Electrostatic Lenses (Einzel lens)
...Show More Authors

In this paper, the path of the extracted and focused ions by the electrostatic lense having three electrodes of the same size and shape have been studied. However, the first and third electrodes had a different potential from the second electrode and the distance between any three electrodes was (d).The beams of the charged particles were controlled by using electrostatic fields which are used for accelerating and focusing. This paper focuses also on the effect of electrodes potentials on ion beam focusing. It is found that the best focusing was achieved when the values of the potential of the first and third electrode are equal to half of the value of the second electrode. Concerning transmiting and acumulating the ions beams, the study sh

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Jan 01 2011
Journal Name
Iraqi Journal Of Physics
Radiation contrast improvement by suitable choice of x-ray radiation spectrum
...Show More Authors

Different bremsstrahlung spectra from tungsten anode x-ray tube generated at 30, 40 and 50 kV have been examined theoretically and experimentally for an attempt to find a most suitable spectrum to radiograph a test object of 0.01 cm thickness of Cu and Ag. The high contrast using this suitable spectrum is demonstrated and the possible effects of fluorescent radiation are discussed.

View Publication Preview PDF
Publication Date
Mon Dec 11 2006
Journal Name
Iraqi Journal Of Laser
Treatment of Bilateral Vocal Cord Paralysis by 810 nm Diode Laser
...Show More Authors

This is prospective study began in Jan. 2003 and concluded in April 2004, was undertaken to examine the benefits of 810 nm diode laser in treatment of four patient with bilateral vocal cord paralysis also to compare the results with conventional treatment Material and methods: 810 nm diode laser 15 watts was used in these cases under general anesthesia, and induction of anesthetic drug done through tracheostomy tube in all patients. All patients were decanulated “Tracheostomy tube removed”, the voice of all preserved within normal. Laser surgery in this case has more benefit and advantage than conventional methods even if the patient need more than on session of laser operation because of high success rate, less complication and easy

... Show More
View Publication Preview PDF
Publication Date
Mon Jun 19 2023
Journal Name
Journal Of Engineering
Improvement of Soil by Using Polymer Fiber Materials Underneath Square Footing
...Show More Authors

The change in project cost, or cost growth, occurs from many factors, some of which are related to soil problem conditions that may occurs during construction and/or during site investigation period. This paper described a new soil improvement method with a minimum cost solution by using polymer fiber materials having a length of (3 cm) in both directions and (2.5 mm) in thickness, distributed in uniform medium dense .
sandy soil at different depths (B, 1.5B and 2B) below the footings. Three square footings has been used (5,7.5 and 10 cm) to carry the above investigation by using lever arm loading system design for such purposes.
These fibers were distributed from depth of (0.1B) below the footing base down to the investigated dep

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sat Dec 30 2017
Journal Name
Al-khwarizmi Engineering Journal
Welding of Low Alloy Steel DIN 15Mo3 by MIG/MAG Spot
...Show More Authors

This research deals with the effects of welding variables using MIG/MAG spot by using Argon (Ar) gas and CO2 to show their effect on the mechanical characteristics and microstructure of low alloy steel type DIN15Mo3 and determine the optimum condition for the process of welding ; current & time. The results show the possibility of using CO2 and also Ar in low alloy steel welding with a little decrease in the shear force of not more than 13% for 4mm thickness and time 2sec. The shear force increased when using Ar instead of CO2 to be , The shear force reach 36KN when using Ar at 2mm thickness  time of 8 sec and current of 220 Amp. , when used CO2 instead of Ar d

... Show More
View Publication Preview PDF
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Excision of Soft Tissue Oral Lesions by 810 nm Diode Laser
...Show More Authors

The present study was conducted on 20 patients suffering from different types of lesion like
pyogenic granuloma, peripheral giant cell granuloma, mucoceles, pregnancy tumour, Fordyce's granules
and irritating fibroma.The cases were selected from outpatient clinic of the Al Kydhemya Teaching
Hospital. Patients were treated by diode laser (810±20 nm) at the affected areas of the oral cavity with
continuous contact focused mode until excision of the lesion with coagulation of the oozing area after
excision. Patients were followed up after 2 days, 7 days and 2 weeks to assess healing process and any
post operative complication. Some of undiagnosed lesion sent for histopathological examination. No
serious complications w

... Show More
View Publication Preview PDF
Publication Date
Sat Mar 29 2025
Journal Name
Iraqi Journal Of Pharmaceutical Sciences
Solubility and Dissolution Rate Enhancement of Bilastine by Solid Dispersion Technique
...Show More Authors

Bilastine (BLS) is non-sedating new-brand H1 antihistamine that has selective peripheral effects, the drug has a problem of an insufficient aqueous solubility and accordingly low dissolution rate, and low bioavailability. Solid dispersion (SD) is one of the most effective techniques for improving the solubility and the dissolution rate of poorly soluble drugs by the dispersion of drug within an inert hydrophilic carrier.   The aim of this study is to increase the solubility and dissolution rate of the BLS using SD technique. Twenty-nine BLS SD formulas were prepared using different carrier polymers include Pluronic 407 (Poloxamer407), Poloxamer188, Urea, Polyethylene glycol 6000 (PEG6000) and Polyvinylpyrrolidone (PVP K30) and em

... Show More
View Publication
Crossref (1)
Scopus Crossref
Publication Date
Sat Feb 01 2020
Journal Name
Civil Engineering Journal
Assessment of Moisture Susceptibility for Asphalt Mixtures Modified by Carbon Fibers
...Show More Authors

Moisture induced damage in asphaltic pavement might be considered as a serious defect that contributed to growth other distresses such as permanent deformation and fatigue cracking. This paper work aimed through an experimental effort to assess the behaviour of asphaltic mixtures that fabricated by incorporating several dosages of carbon fiber in regard to the resistance potential of harmful effect of moisture in pavement. Laboratory tests were performed on specimens containing fiber with different lengths and contents. These tests are: Marshall Test, the indirect tensile test and the index of retained strength. The optimum asphalt contents were determined based on the Marshall method. The preparation of asphaltic mixtures involved

... Show More
Scopus (26)
Crossref (19)
Scopus Clarivate Crossref
Publication Date
Fri Nov 10 2023
Journal Name
Chalcogenide Letters
Enhancement efficiency of cadmium selenium solar cell by doping within silver
...Show More Authors

We studied at the morphology, structural setup, and optical characteristics of thin cadmium (CdSe) films a thickness of 250 nm that were created by thermal evaporation over glass, The films exhibited a hexagonal shape were crystalline, and tended to form grains in the (111) crystallographic direction, according to the X-ray diffraction examinations. These characteristics were established using the investigation's findings. Through the use of thin films of CdSe doped with Ag at a concentration of 1.5%, the crystal structure orientations for pure CdSe (25.32, 41.84) and CdSe:Ag (25.39, 41.01) that were both pure as well as those that were doped with silver were both determined. The band gap of the optical spectrum decreased by 1.93–

... Show More
View Publication
Scopus (7)
Crossref (7)
Scopus Clarivate Crossref