Background: As photochemical reaction that can stiffen the cornea, CXL is the only promising method of preventing progression of keratectasia such as KC and secondary ectasia following refractive surgery. The aim of CXL is to stabilize the underlying condition with a small chance of visual improvement. Objective: To show the sequences of changes in visual acuity and topographic outcomes during 1 year post CXL for patients with progressive Keratoconus.Type of the study: Cross sectional studyMethods: CXL procedure was done for 45 eyes with progressive KC. The following parameters had been monitored pre operatively, 1, 3, 6 and 12 months postoperatively: K apex, K2, corneal thickness at thinnest location, anterior and posterior elevation points, BCVA and UCVA. Placido –Scheimpflug topography (Sirius) device had been used to monitor the corneal parameters of the study. One –way ANOVA and Paired sample T test was used for statistical analysis.The study done in Lasik specialty center /Baghdad/IraqResults: At 1 year, an averages flattening of (2.11 D) diopter in K2 and (1.88 D) diopter in K apex were found. Mean BCVA improved by 1 line from (0.18) Log MAR to (0.13) Log MAR and mean UCVA improved by 3.5 lines from (0.89) to (0.64) log MAR. The corneal thickness at thinnest location was 5.71 Mm less than the baseline. All the above mentioned parameters showed a trend of worsening between the baseline and 1 month, and improvement thereafter. We found no statistically significant changes in the anterior elevation points while the posterior elevation point changed (increased) significantly.Conclusions: Corneal collagen cross-linking seems to be effective in decreasing progression of KC , with improvements in optical measures in many patients. Post operative parameters discussed within this review followed a seemingly reproducible trend in there natural course over 12 months .Generally, the trend that observed was immediate worsening between baseline and 1 month resolution at approximately 3 months, and improvement thereafter.
Visualization of subsurface geology is mainly considered as the framework of the required structure to provide distribution of petrophysical properties. The geological model helps to understand the behavior of the fluid flow in the porous media that is affected by heterogeneity of the reservoir and helps in calculating the initial oil in place as well as selecting accurate new well location. In this study, a geological model is built for Qaiyarah field, tertiary reservoir, relying on well data from 48 wells, including the location of wells, formation tops and contour map. The structural model is constructed for the tertiary reservoir, which is an asymmetrical anticline consisting of two domes separated by a saddle. It is found that
... Show MoreA total of 96 stool samples were collected from children with bloody diarrhea from two hospitals in Baghdad. All samples were surveyed and examined for the presence of the Escherichia coli O157:H7 and differentiate it from other Non -Sorbitol Fermenting Escherichia coli (NSF E. coli). The Bacterial isolates were identifed by using morphological diagnostic methods, Samples were cultured on liquid enrichment medium, incubated at 37C? for 24 hrs, and then cultured on Cefixime Tellurite -Sorbitol MacConkey Agar (CT- SMAC). 32 non-sorbitol fermenting bacterial isolates were obtained of which 11 were identified as Escherichia coli by using traditional biochemical tests and API20E diagnostic system without differentiation between
... Show MoreThe objective of this work is to investigate the performance of a conventional three phase induction motor supplied by unbalanced voltages. An effort to study the motor steady state performance under this disturbance is introduced. Using per phase equivalent circuit analysis with the concept of symmetrical components approach, the steady state performance is theoretically calculated. Also, a model for the induction motor with the MATLAB/Simulink SPS tools has been implemented and steady state results were obtained. Both results are compared and show good correlation as well. The simulation model is introduced to support and enhance electrical engineers with a complete understanding for the steady state performance of a fully loaded induc
... Show MoreTotal quality management considers one of the modern scientific entrances which practiced by productivity service organizations alike to provide appropriate quality required outputs according to the needs and desires of customers manage , enable the organization seeking to continue and grow in light of the increasing competition from the satisfy and provide the appropriate total quality management requirements whenever led to face risks that they may have in a manner in which they can be addressed and find ways to avoid them in the future when repeated. &n
... Show MoreDouble-layer micro-perforated panels (MPPs) have been studied extensively as sound absorption systems to increase the absorption performance of single-layer MPPs. However, existing proposed models indicate that there is still room for improvement regarding the frequency bands of absorption for the double-layer MPP. This study presents a double-layer MPP formed with two single MPPs with inhomogeneous perforation backed by multiple cavities of varying depths. The theoretical formulation is developed using the electrical equivalent circuit method to calculate the absorption coefficient under a normal incident sound. The simulation results show that the proposed model can produce absorption coefficient with wider absorption bandwidth compared w
... Show MoreThis study is the first investigation in Iraq dealing with genotyping of
Epstein-Barr Virus (EBV) infection is associated with broad spectrum of clinical manifestationsdepending on the immune status of the host, To analyze their possible role in the complication ofautoimmune hepatitis, we investigated (30) female patients with autoimmune hepatitis type-1 of(10-40)years and 25 healthy female of same ages(control groups). Both groups were carried outto measure the levels of EBV-CA IgM, IgG Ab, EBV-EA IgM, IgG Ab, and EBV-NA IgM, IgGAb using indirect immunoflourescent assay (IFAT).The prevalence of EBV-CA IgM, IgG Ab were(10%,20%) and EBV-EA IgM, IgG Ab were (10% and20%) respectively, while the prevalence ofEBV-NA IgG Ab was( 3.33%) and there are no prevalence of EBV-NA IgM Ab. There weresignificant differences (P
... Show More