Background: As photochemical reaction that can stiffen the cornea, CXL is the only promising method of preventing progression of keratectasia such as KC and secondary ectasia following refractive surgery. The aim of CXL is to stabilize the underlying condition with a small chance of visual improvement. Objective: To show the sequences of changes in visual acuity and topographic outcomes during 1 year post CXL for patients with progressive Keratoconus.Type of the study: Cross sectional studyMethods: CXL procedure was done for 45 eyes with progressive KC. The following parameters had been monitored pre operatively, 1, 3, 6 and 12 months postoperatively: K apex, K2, corneal thickness at thinnest location, anterior and posterior elevation points, BCVA and UCVA. Placido –Scheimpflug topography (Sirius) device had been used to monitor the corneal parameters of the study. One –way ANOVA and Paired sample T test was used for statistical analysis.The study done in Lasik specialty center /Baghdad/IraqResults: At 1 year, an averages flattening of (2.11 D) diopter in K2 and (1.88 D) diopter in K apex were found. Mean BCVA improved by 1 line from (0.18) Log MAR to (0.13) Log MAR and mean UCVA improved by 3.5 lines from (0.89) to (0.64) log MAR. The corneal thickness at thinnest location was 5.71 Mm less than the baseline. All the above mentioned parameters showed a trend of worsening between the baseline and 1 month, and improvement thereafter. We found no statistically significant changes in the anterior elevation points while the posterior elevation point changed (increased) significantly.Conclusions: Corneal collagen cross-linking seems to be effective in decreasing progression of KC , with improvements in optical measures in many patients. Post operative parameters discussed within this review followed a seemingly reproducible trend in there natural course over 12 months .Generally, the trend that observed was immediate worsening between baseline and 1 month resolution at approximately 3 months, and improvement thereafter.
In this article it is proved experimentally that the photon is a particle that has mass and constant wavelength by explaining the effect of refractive index on the wavelength and the natural mass of photon. It is very difficult to measure the mass of photon, a simple and easy process was proposed in this paper to calculate the mass length of photon in vacuum (Y) and in medium (Y*), by measuring the length of laser beam in air (Lair) and in medium (Lmed). A new method was postulated to calculate refractive index by using these relations (n = Y*/Y), and (n = Lmed / Lair) which supposed a new theory of light.
Criticism, as an evaluative criterion, is a significant speech act for English language learners to improve their speech and actions in their academic life. Yet, it is realized differently across diverse cultures. Few studies have shown that the linguistics forms of one language are different from those available in another language. Hence, this study aims to investigate the cross-cultural similarities and differences between 60 Iraqi and Malay university learners in the use of criticism strategies. The data are collected using a Discourse Completion Test (DCT) and a Focus Group Interview (FGI). The data are coded based on Nguyen’s (2005) coding scheme of criticism in terms of the realization strategies. Qualitative
... Show MoreIt is obvious that the constitutional- political structures which has been emerged in Iraq after the occupation in 2003 frame worked by many sectarian, ethnic, tribal and political orientations, pushing forewords to escalating the contradictions between social- political powers, however, these changes unfortunately result not just destroy and taking apart the political regime and his authority, but the state and his institutions as well, although, did not stamped as wise and rational change for better future to new Iraq and its political, civil and military institutions. Finally, as quick as Iraq start to bisects to sectarian, ethnic and national components according to the new political – social components of Iraq. Indeed, what is req
... Show More
Abstract
Natural gas is characterized by features that made from it a fuel and a raw material for many industries. Deepening its position as a favorite fossil supplier between other types of fossil fuel is the efficiency, diversity of its uses, low costs and compatibility with the environment which leads to increasing of its uses then increased global demand. So, the natural gas must take its place as an important resource in Iraq and participate the oil in the economic development process of building and financing of the general budget.
Iraq is planning to continue of increasing the export capacity of raw oil to meet ambitious production targets emanating from the mai
... Show MoreFor several applications, it is very important to have an edge detection technique matching human visual contour perception and less sensitive to noise. The edge detection algorithm describes in this paper based on the results obtained by Maximum a posteriori (MAP) and Maximum Entropy (ME) deblurring algorithms. The technique makes a trade-off between sharpening and smoothing the noisy image. One of the advantages of the described algorithm is less sensitive to noise than that given by Marr and Geuen techniques that considered to be the best edge detection algorithms in terms of matching human visual contour perception.
Students in the twenty-first century need to find innovative ways to satisfy and respond to these learning requirements since they live in a visible world that is continuously surrounded by visual, technological stimuli. This is especially true of higher education. In order promote advancements in sustainable awareness, the project aims to include visual understanding in education (VUE) in higher education communication skills. An interview has been employed as a tool to accomplish the study's goal. The idea of Visual Understanding in Education (VUE) is one of the many novel or modern ways that has produced remarkable outcomes in a wide range of specialized sectors. Teachers may spread lessons of responsibility and consciousness by being aw
... Show MoreThe nature of the dark sector of the Universe remains one of the outstanding problems in modern cosmology, with the search for new observational probes guiding the development of the next generation of observational facilities. Clues come from tension between the predictions from Λ cold dark matter (ΛCDM) and observations of gravitationally lensed galaxies. Previous studies showed that galaxy clusters in the ΛCDM are not strong enough to reproduce the observed number of lensed arcs. This work aims to constrain the warm dark matter (WDM) cosmologies by means of the lensing efficiency of galaxy clusters drawn from these alternative models. The lensing characteristics of two samples of simulated clusters in the Λ warm dark matter and ΛCDM
... Show MoreThe Multiple Signal Classification (MUSIC) algorithm is the most popular algorithm to estimate the Angle of Arrival (AOA) of the received signals. The analysis of this algorithm (MUSIC) with typical array antenna element ( ) shows that there are two false direction indication in the plan
aligned with the axis of the array. In this paper a suggested modification on array system is proposed by using two perpendiculars crossed dipole array antenna in spite of one array antenna. The suggested modification does not affect the AOA estimation algorithm. The simulation and results shows that the proposed solution overcomes the MUSIC problem without any effect on the performance of the system.
Background: Currently there are four general approaches to correct refractive errors: refractive corneal surgery, crystalline lens surgery and implantation of an intraocular lens in anterior or posterior chamber. Aim: To evaluate the predictability, safety and stability of toric phakic implantable collamer lens implantation to correct moderate to high myopic astigmatism. Methods: Sixty eyes of 40 patients underwent implantation of a toric implantable collamer lens (V4c design) in the Eye Specialty Private Hospital, Baghdad, Iraq were studied. The mean spherical refraction was -11.32±3.17 diopter (D) with a range of -6.00 to -18.00 D and a mean cylinder of -2.61±1.16 with range of -1.00 to -5.50 D. The outcome measures that evaluat
... Show MoreBackground: Currently there are four general approaches to correct refractive errors: refractive corneal surgery, crystalline lens surgery and implantation of an intraocular lens in anterior or posterior chamber.
Objective: To evaluate the predictability, safety and stability of toric phakic implantable collamer lens implantation to correct moderate to high myopic astigmatism. in Eye Specialty Private Hospital, Baghdad, Iraq.
Type of the Study: a prospective non randomize intervention study.
Methods: 60 eyes of 40 patients underwent implantation of a toric implantable collamer lens (V4c design).Mean spherical refraction was ₋11.32 diopter
... Show More