Background: Energy drinks are non alcoholic beverages which contain stimulant drugs chiefly caffeine and marketed as mental and physical stimulators. Consumption of energy drinks is popular practice among college students as they are exposed to academic stress. Caffeine which is the main constituent of energy drinks could become an addictive substance or cause intoxication. Objectives: This study aims to assess the prevalence of energy drinks consumption among medical students of alkindy college of Medicine.Type of the study: A cross sectional study.Methods: It was performed at alkindy medical college on March 2016. A total number of 600 students were contacted to participate in this study. A self administered questionnaire was used to collect the data. Spss version 18.0 was used for statistical analysis.Results: Out of 600 students, 501 (83.5%) participated in the study. The majority were females 304 (60.7%) and only 197 (39.3%) were males with a mean age of (20.43 ± 1.74). 120 (24%) of participants had consumed energy drinks at least once. Higher proportion of male students 77 (64%) consumed energy drinks compared to females 43 (36%). Regarding inspiration of first use of energy drinks, the highest percentage 9.8% was due to friends. Majority of consumers 85 (17.2%) used energy drinks irregularly. The main cause of energy drinks consumption was focusing for studying 7.2% (n=36). Conclusions: Energy drinks consumption is a common practice among medical students. Friends had a strong influence on usage of energy drinks. Students consumed energy drinks mainly for focusing for studying. Further studies are recommended to evaluate factors involved in consumption of these drinks among medical students and their understanding of the risks involved as well as possible interventions to promote safe consumption
تشغل الفضاءات الداخلية الطبية اهتمام واسع , لما توفره من رعاية صحية للمرضى ,فلابد ان يُهتَمْ بها من الجانب الوظيفي(الادائي), لتحقيق الراحة البصرية والنفسية والجسدية لغرض الوصول الى الاداء الجيد للكادر الطبي, ولهذا وجد ضرورة التعرف على تلك الفضاءات الداخلية بشكل اعمق , وهل انها ملاءمة للمرتكزات التصميمية المتعارف عليها؟ , لذلك تم تسليط الضوء على الفضاءات الداخلية للمختبرات الطبية, وقد تناول البحث المشكلة واه
... Show MoreHigh frequencies of multidrug resistant organisms were observed worldwide in intensive care units which is a warning as to use the only few effective antimicrobials wisely to reduce selective pressure on sensitive strains.
The aim of the current study is to asses the compliance of the currently followed antibiotic prescribing pattern in the intensive care unit in an Iraqi hospital with the international guidelines.A cross-sectional study was done in the intensive care unit (ICU) of the Surgical Specialties Hospital, Medical City in Bagdad from the 30th of November 2011 to the 5th of May 2012.Patients were followed until they were discharged or died to see any change in condition, response to drugs, devices u
... Show MoreThe internet of medical things (IoMT), which is expected the lead to the biggest technology in worldwide distribution. Using 5th generation (5G) transmission, market possibilities and hazards related to IoMT are improved and detected. This framework describes a strategy for proactively addressing worries and offering a forum to promote development, alter attitudes and maintain people's confidence in the broader healthcare system without compromising security. It is combined with a data offloading system to speed up the transmission of medical data and improved the quality of service (QoS). As a result of this development, we suggested the enriched energy efficient fuzzy (EEEF) data offloading technique to enhance the delivery of dat
... Show MoreThirty swabes of medical implants were collected from Al-Yarmouk's hospital which were cultured on manitole agar to isolate Staphelococcus aureus . Only four samples gave positive results with this media. It was used ten types of antibiotics to test the sensitivity of this bacterium against them. All isolates of S. aureus were recorded as multidrug resistant and were considered as MRSA. One pledge alternative therapy is the utilize of certain pure bacterocin MIC (32.5 to 62.5 μg/ml) and it was compared with vancomycin (200-400 μg/ml) with average of (8 – 15) mm diameter of inhibition zones recpectively. The first reduction of biofilm formation ability has been proved in catheters when treatedby pure bacterocin. The test shows the highes
... Show MoreThe rapid development of telemedicine services and the requirements for exchanging medical information between physicians, consultants, and health institutions have made the protection of patients’ information an important priority for any future e-health system. The protection of medical information, including the cover (i.e. medical image), has a specificity that slightly differs from the requirements for protecting other information. It is necessary to preserve the cover greatly due to its importance on the reception side as medical staff use this information to provide a diagnosis to save a patient's life. If the cover is tampered with, this leads to failure in achieving the goal of telemedicine. Therefore, this work provides an in
... Show MorePhase change materials (PCMs) such as paraffin wax can be used to store or release large amount of energy at certain temperature at which their solid-liquid phase changes occurs. Paraffin wax that used in latent heat thermal energy storage (LHTES) has low thermal conductivity. In this study, the thermal conductivity of paraffin wax has been enhanced by adding different mass concentration (1wt.%, 3wt.%, 5wt.%) of (TiO2) nano-particles with about (10nm) diameter. It is found that the phase change temperature varies with adding (TiO2) nanoparticles in to the paraffin wax. The thermal conductivity of the composites is found to decrease with increasing temperature. The increase in thermal conductivity ha
... Show MoreThe effect of refrigerant injection techniques on the performance of heat pump system based on exergy analysis was studied theoretically. Three refrigerant injection techniques were used; the first was achieved by injected vapour in volume ratios from 1 to 7% in the accumulator. The second was injection liquid refrigerant in the discharge line with the aid of Liquid Pressure Amplification (LPA) pump, with volume ratios from 1 to 10%. The third was a hybrid injection with volume ratios of injected vapour and liquid varied from 1 to 3% and 1 to 10%; respectively. The following improvements in cycle performance were observed. For vapour injection technique, the best ratio of injection was 5%, the exergy destruction reduced
... Show MoreRenewable energy resources have become a promissory alternative to overcome the problems related to atmospheric pollution and limited sources of fossil fuel energy. The technologies in the field of renewable energy are used also to improve the ventilation and cooling in buildings by using the solar chimney and heat exchanger. This study addresses the design, construction and testing of a cooling system by using the above two techniques. The aim was to study the effects of weather conditions on the efficiency of this system which was installed in Baghdad for April and May 2020. The common weather in these months is hot in Baghdad. The test room of the design which has a size of 1 m3 was situated to face the geographical south. The te
... Show MoreThis study investigates the constructs and related theories that drive social capital in energy sector from the intention perspectives. This research uses theories of 'social support' and 'planned behaviour' alongside satisfaction and perceived value to propose a research model that drives social capital for energy sectors in Malaysia. The model reveals that the Theories of Planned Behaviour (TPB) and Social Support Theory (SST) alongside satisfaction and perceived value factors promote social capital development in energy sectors. Using PLS-SEM to analyse data gathered from energy sector employees in Malaysia, this research demonstrates that social capital is present when there is trust and loyalty among the users and positively effects en
... Show MoreAbstract
This work deals with a numerical investigation to evaluate the utilization of a water pipe buried inside a roof to reduce the heat gain and minimize the transmission of heat energy inside the conditioning space in summer season. The numerical results of this paper showed that the reduction in heat gain and energy saving could be occurred with specific values of parameters, like the number of pipes per square meter, the ratio of pipe diameter to the roof thickness, and the pipe inlet water temperature. Comparing with a normal roof (without pipes), the results indicated a significant reduction in energy heat gain which is about 37.8% when the number of pipes per m
... Show More