Background: The normal decline in systolic blood pressure during recovery phase of treadmill exercise dose not occur in most patients with coronary artery disease, in others recovery values systolic blood pressure may even exceed the peak exercise value. Objectives: Treadmill exercise test parameters indicating the presence and extent of coronary artery disease have traditionally included such as exercise duration, blood pressure and ST-segment response to exercise. The three –minute systolic blood pressure ratio is another important indicator of presence and significance of coronary artery disease is useful and obtainable measure that can be applied in all patients who are undergoing stress testing for evaluation of suspected ischemic heart disease and this increase the sensitivity of exercise test . Type of the study: A prospective study. Methods: Between April 2011 and April 2012 ,all patients underwent treadmill exercise test , echocardiography coronary angiography in Ibn Ab-bitar Hospital Cardiac Surgery. Clinical and procedural data for patients undergoing treadmill and coronary angiography were prospectively collected and entered into database specially designed for the present study.To calculate mean systolic blood pressure ratio for each , Measurement of blood pressure in the 3rd minute of recovery time and divided by peak systolic blood pressure during exercise test ,after excluding patients . Coronary angiography was done for all patients who under went treadmill exercise test and multiple views were taken accordingly to clarify the lesion and critical lesion defined as >50% stenosis in LMS and >70% stenosis in LAD,LCX and RCA. Results: We studied 100 patients In the period from April 2011 to April 2012, 78(78%) male and 22 (22%) a female with a mean age 55.49±7.60 who undergone treadmill exercise testing and coronary angiography to assess the chest pain, 32 patient had normal blood pressure 68 had hypertension and 24 patients had normal coronary angiography and 76 patients had abnormal coronary angiography. SBP/3 minute recovery blood pressure ratio was significantly higher in patient with coronary artery disease than patient without coronary artery disease (mean ±SD O.92±0.09 VS 0.81 SBP/3 minute recovery blood pressure ratio was significantly related with the severity of coronary artery disease its higher in three vessels than one vessel disease 0.95±0.10 vs0. 91 ±0.01 p-value 0.0001. Conclusions: post exercise blood pressure response in patients with coronary artery diseaseis higher than patients with normal coronary artery .post exercise blood pressure is related to the severity of coronary artery disease
This study was aimed to investigate the response surface methodology (RSM) to evaluate the effects of various experimental conditions on the removal of levofloxacin (LVX) from the aqueous solution by means of electrocoagulation (EC) technique with stainless steel electrodes. The EC process was achieved successfully with the efficiency of LVX removal of 90%. The results obtained from the regression analysis, showed that the data of experiential are better fitted to the polynomial model of second-order with the predicted correlation coefficient (pred. R2) of 0.723, adjusted correlation coefficient (Adj. R2) of 0.907 and correlation coefficient values (R2) of 0.952. This shows that the predicted models and experimental values are in go
... Show MoreThe dynamic behavior of laced reinforced concrete (LRC) T‐beams could give high‐energy absorption capabilities without significantly affecting the cost, which was offered through a combination of high strength and ductile response. In this paper, LRC T‐beams, composed of inclined continuous reinforcement on each side of the beam, were investigated to maintain high deformations as predicted in blast resistance. The beams were tested under four‐point loading to create pure bending zones and obtain the ultimate flexural capacities. Transverse reinforcement using lacing reinforcement and conventional vertical stirrups were compared in terms of deformation, strain, and toughness changes of the tes
This paper investigates the experimental response of composite reinforced concrete with GFRP and steel I-sections under limited cycles of repeated load. The practical work included testing four beams. A reference beam, two composite beams with pultruded GFRP I-sections, and a composite beam with a steel I-beam were subjected to repeated loading. The repeated loading test started by loading gradually up to a maximum of 75% of the ultimate static failure load for five loading and unloading cycles. After that, the specimens were reloaded gradually until failure. All test specimens were tested under a three-point load. Experimental results showed that the ductility index increased for the composite beams relative to the refe
... Show MoreIn the recent decade, injection of nanoparticles (NPs) into underground formation as liquid nanodispersions has been suggested as a smart alternative for conventional methods in tertiary oil recovery projects from mature oil reservoirs. Such reservoirs, however, are strong candidates for carbon geo-sequestration (CGS) projects, and the presence of nanoparticles (NPs) after nanofluid-flooding can add more complexity to carbon geo-storage projects. Despite studies investigating CO2 injection and nanofluid-flooding for EOR projects, no information was reported about the potential synergistic effects of CO2 and NPs on enhanced oil recovery (EOR) and CGS concerning the interfacial tension (γ) of CO2-oil system. This study thus extensively inves
... Show MoreThe V2O5 films were deposited on glass substrates which produce using "radio frequency (RF)"power supply and Argon gas technique. The optical properties were investigated by, UV spectroscopy at "radio frequency" (RF) power ranging from 75 - 150 Watt and gas pressure, (0.03, 0.05 and 0.007 Torr), and substrate temperature (359, 373,473 and 573) K. The UV-Visible analysis shows that the average transmittance of all films in the range 40-65 %. When the thickness has been increased the transhumance was decreased from (65-40) %. The values of energy band gap were lowered from (3.02-2.9 eV) with the increase of thickness the films in relation to an increase in power, The energy gap decreased (2.8 - 2.7) eV with an increase in the pressure and
... Show MorePhotoplethysmography (PPG) is a non-invasive optical technique that employs variations in light absorption produced by alteration in the blood volume in capillaries at the skin during the cardiac cycle. This study aims to understand factors related to PPG morphology; a hand-elevation, the study has modified blood flow to and from the finger was conducted in the laboratory. It is widely established that the position of the limb relative to the heart has an effect on blood flow in arteries and venous. Peripheral digital pulse wave (DPW) signals were obtained from 15 healthy volunteer participants during hand-elevation, and hand-lowering techniques wherein the right hand was lifted and lowered relative to heart level, while the left h
... Show MoreAs major nosocomial pathogens,
In this study, 20
This Study aimed To know The relation between Types of blood and health problems which human Suffered from , and the effect of food intake on health.
Samples of study contained 269 person aged between 30 – 70 years which choiced randomly for sex , we are take all in formation about samples of study by form paper contian sex , age, type of blood , weight (kg) , height (cm) , smoking or.not , sporting or not, problems in digestive tract , sensitivity for foods , heart problems , ratio of cholesterol in blood , Sinusitis , Asthma , diabetic meliuts , arritable bowel syndrome , diaherra , problems in kidney and urination , hypertension , anemia , alternation in liver function , arthritis with form record in daily food intake and its ade
Abstract: Background: High percentage of diabetes patients complain from post extraction hemorrhage. Many types of hemostatic materials are used to stop bleeding after teeth extraction: diode lasers are good hemostatic agents owing to their highly absorption by hemoglobin therefore they are used in soft tissue procedures with relatively no effects on dental hard tissues due to their poorly absorption by water and hydroxyapatite. Objectives: The aim of this study is to evaluate the efficiency of diode laser to assist the clot formation after tooth extraction for type II diabetes patients with minimum temperature elevation to prevent periodontal destruction. Materials and methods: From 12 type II diabetes patients (7 males and 5 females wi
... Show More