Background: The normal decline in systolic blood pressure during recovery phase of treadmill exercise dose not occur in most patients with coronary artery disease, in others recovery values systolic blood pressure may even exceed the peak exercise value. Objectives: Treadmill exercise test parameters indicating the presence and extent of coronary artery disease have traditionally included such as exercise duration, blood pressure and ST-segment response to exercise. The three –minute systolic blood pressure ratio is another important indicator of presence and significance of coronary artery disease is useful and obtainable measure that can be applied in all patients who are undergoing stress testing for evaluation of suspected ischemic heart disease and this increase the sensitivity of exercise test . Type of the study: A prospective study. Methods: Between April 2011 and April 2012 ,all patients underwent treadmill exercise test , echocardiography coronary angiography in Ibn Ab-bitar Hospital Cardiac Surgery. Clinical and procedural data for patients undergoing treadmill and coronary angiography were prospectively collected and entered into database specially designed for the present study.To calculate mean systolic blood pressure ratio for each , Measurement of blood pressure in the 3rd minute of recovery time and divided by peak systolic blood pressure during exercise test ,after excluding patients . Coronary angiography was done for all patients who under went treadmill exercise test and multiple views were taken accordingly to clarify the lesion and critical lesion defined as >50% stenosis in LMS and >70% stenosis in LAD,LCX and RCA. Results: We studied 100 patients In the period from April 2011 to April 2012, 78(78%) male and 22 (22%) a female with a mean age 55.49±7.60 who undergone treadmill exercise testing and coronary angiography to assess the chest pain, 32 patient had normal blood pressure 68 had hypertension and 24 patients had normal coronary angiography and 76 patients had abnormal coronary angiography. SBP/3 minute recovery blood pressure ratio was significantly higher in patient with coronary artery disease than patient without coronary artery disease (mean ±SD O.92±0.09 VS 0.81 SBP/3 minute recovery blood pressure ratio was significantly related with the severity of coronary artery disease its higher in three vessels than one vessel disease 0.95±0.10 vs0. 91 ±0.01 p-value 0.0001. Conclusions: post exercise blood pressure response in patients with coronary artery diseaseis higher than patients with normal coronary artery .post exercise blood pressure is related to the severity of coronary artery disease
This research is carried out to study the effect of the external post-tensioning technique on the flexural capacity of simply supported composite castellated beam experimentally. In this research, seven composite castellated beams having the same dimensions and material properties were cast and tested up to failure by applied two concentrated loads at 700 mm from each end. Two external strands of 12.7 mm diameter were fixed at each side of the web of strengthening beams and located at depth 180 mm from top fiber of the section (dps) at each end of the beam. The strands have been tensioned by using a hydraulic jack with a constant stress of 100 MPa. This research aims to study the effect of the strengthening by different shapes of st
... Show MoreThe study aims to identify the symptoms of PTSD among displaced Yazidi women according to age, marital status, educational level, and type of status (displaced or survivor). The study also seeks to identify the effect of the relaxation program on reducing PTSD among displaced Yazidi women. The research sample included (60) Yazidis for the statistical analysis sample and (5) for the experimental sample in the Dohuk governorate. For achieving the research objectives, a scale was used from the PTSD Checklist for DSM-5 (PCL-5), as well as a relaxation program was prepared. The researchers reached the following results that there is an average level of PTSD symptoms among displaced Yazidi women, there are no statistically significant differen
... Show MoreA novel metal-organic framework (MOF) sorbent based on tannic acid/copper (TA/Cu) was synthesized and characterized for the application of the anticancer drug imatinib (IMA) from biological samples. The TA/Cu MOF was prepared via a facile coordination reaction and thoroughly characterized by SEM, XRD, and FTIR techniques. Critical parameters influencing the extraction efficiency of imatinib mesylate (IMAM), including pH, ionic strength, desorption solvent, and adsorption-desorption time were optimized. With acetonitrile as the desorption solvent, the method demonstrated a broad linear range of 0.55-300 μg L-1 under ideal conditions. Limits of detection and quantification were found to be 0.16 μg L-1 and 0.55 μg L-1, respectively.
... Show MoreA novel metal-organic framework (MOF) sorbent based on tannic acid/copper (TA/Cu) was synthesized and characterized for the application of the anticancer drug imatinib (IMA) from biological samples. The TA/Cu MOF was prepared via a facile coordination reaction and thoroughly characterized by SEM, XRD, and FTIR techniques. Critical parameters influencing the extraction efficiency of imatinib mesylate (IMAM), including pH, ionic strength, desorption solvent, and adsorption-desorption time were optimized. With acetonitrile as the desorption solvent, the method demonstrated a broad linear range of 0.55-300 μg L-1 under ideal conditions. Limits of detection and quantification were found to be 0.16 μg L-1 and 0.55 μg L-1, respectively.
... Show MoreA novel metal-organic framework (MOF) sorbent based on tannic acid/copper (TA/Cu) was synthesized and characterized for the application of the anticancer drug imatinib (IMA) from biological samples. The TA/Cu MOF was prepared via a facile coordination reaction and thoroughly characterized by SEM, XRD, and FTIR techniques. Critical parameters influencing the extraction efficiency of imatinib mesylate (IMAM), including pH, ionic strength, desorption solvent, and adsorption-desorption time were optimized. With acetonitrile as the desorption solvent, the method demonstrated a broad linear range of 0.55-300 μg L-1 under ideal conditions. Limits of detection and quantification were found to be 0.16 μg L-1 and 0.55 μg L-1, respectively.
... Show MoreThis paper presents an enhancement technique for tracking and regulating the blood glucose level for diabetic patients using an intelligent auto-tuning Proportional-Integral-Derivative PID controller. The proposed controller aims to generate the best insulin control action responsible for regulating the blood glucose level precisely, accurately, and quickly. The tuning control algorithm used the Dolphin Echolocation Optimization (DEO) algorithm for obtaining the near-optimal PID controller parameters with a proposed time domain specification performance index. The MATLAB simulation results for three different patients showed that the effectiveness and the robustness of the proposed control algorithm in terms of fast gene
... Show More