Background: The normal decline in systolic blood pressure during recovery phase of treadmill exercise dose not occur in most patients with coronary artery disease, in others recovery values systolic blood pressure may even exceed the peak exercise value. Objectives: Treadmill exercise test parameters indicating the presence and extent of coronary artery disease have traditionally included such as exercise duration, blood pressure and ST-segment response to exercise. The three –minute systolic blood pressure ratio is another important indicator of presence and significance of coronary artery disease is useful and obtainable measure that can be applied in all patients who are undergoing stress testing for evaluation of suspected ischemic heart disease and this increase the sensitivity of exercise test . Type of the study: A prospective study. Methods: Between April 2011 and April 2012 ,all patients underwent treadmill exercise test , echocardiography coronary angiography in Ibn Ab-bitar Hospital Cardiac Surgery. Clinical and procedural data for patients undergoing treadmill and coronary angiography were prospectively collected and entered into database specially designed for the present study.To calculate mean systolic blood pressure ratio for each , Measurement of blood pressure in the 3rd minute of recovery time and divided by peak systolic blood pressure during exercise test ,after excluding patients . Coronary angiography was done for all patients who under went treadmill exercise test and multiple views were taken accordingly to clarify the lesion and critical lesion defined as >50% stenosis in LMS and >70% stenosis in LAD,LCX and RCA. Results: We studied 100 patients In the period from April 2011 to April 2012, 78(78%) male and 22 (22%) a female with a mean age 55.49±7.60 who undergone treadmill exercise testing and coronary angiography to assess the chest pain, 32 patient had normal blood pressure 68 had hypertension and 24 patients had normal coronary angiography and 76 patients had abnormal coronary angiography. SBP/3 minute recovery blood pressure ratio was significantly higher in patient with coronary artery disease than patient without coronary artery disease (mean ±SD O.92±0.09 VS 0.81 SBP/3 minute recovery blood pressure ratio was significantly related with the severity of coronary artery disease its higher in three vessels than one vessel disease 0.95±0.10 vs0. 91 ±0.01 p-value 0.0001. Conclusions: post exercise blood pressure response in patients with coronary artery diseaseis higher than patients with normal coronary artery .post exercise blood pressure is related to the severity of coronary artery disease
Multilayer reservoirs are currently modeled as a single zone system by averaging the reservoir parameters associated with each reservoir zone. However, this type of modeling is rarely accurate because a single zone system does not account for the fact that each zone's pressure decreases independently. Pressure drop for each zone has an effect on the total output and would result in inter-flow and the premature depletion of one of the zones. Understanding reservoir performance requires a precise estimation of each layer's permeability and skin factor. The Multilayer Transient Analysis is a well-testing technique designed to determine formation properties in more than one layer, and its effectiveness over the past two decades has been
... Show MoreThe economical design of plate loaded by pressure can be obtained by using stiffeners instead of increasing the thickness of plate. The main subject of this work is to obtain the effect of stiffener height on the maximum stress in the plate subjected to pressure load. Different plate-stiffener sets are selected to find the effects of stiffener thickness, plate dimensions and pressure, on the optimum stiffener height. The models under consideration are square plates clamped rigidly from four edges. Finite Element method is used to analyze 160 different models by using the Finite Element software package ANSYS version 11. Another analysis method based on maximum stress equation is used to analyze 30 models. The graphical comparison of results
... Show MoreEquation Boizil used to Oatae approximate value of bladder pressure for 25 healthy people compared with Amqas the Alrotinahh ways used an indirect the catheter Bashaddam and found this method is cheap and harmless and easy
Previous reports demonstrated the effectiveness of silibinin hemisuccinate as a potential intraocular pressure-lowering agent. The exact mechanism by which silibinin exerted this effect has not yet been documented, but might suggested to interfere with aqueous humor formation. The present study was designed to evaluate the comparative efficacy of silibinin as IOP lowering agent to that of betaxolol in normotensive rabbits, and the interaction of silibinin with betaxolol as a way for investigating the possible mechanism of action of silibinin in this respect. The effects of instillation of 0.75% silibinin solution and 0.5% betaxolol eye drops in the eyes of normotensive rabbits were evaluated using indentation tonometry. The results showe
... Show MoreThis research studying the phenomenon of Doppler (frequency Doppler) as a method through which the direction and speed of the blood cells flows in blood vessels wear measured. This Doppler frequency is relied upon in medicine for measuring the speed of blood flow, because the blood flow is an important concept from the concepts of medicine. It represents the function and efficient of the heart and blood vessels in the body so any defect in this function will appear as a change in the speed of blood flow from the normal value assumed. As this speed changes alot in cases of disease and morbidity of the heart, so in order to identify the effect of changing the Doppler frequency on the speed of blood flow and the relationship of
... Show MoreDirect agglutination test was used to evaluate the immunogenicity of three different antigens inoculated in hamsters as one , two and three doses which were: Group (1) inoculated with autoclaved killed Leishmania tropica , Group (2) inoculated with BCG vaccine alone while Group (3) inoculated with mixed antigens (autoclaved killed Leishmania "AKL"+ BCG).(4) Control animals inoculated with phosphate buffer saline. The maximum level of antibody titers were evaluated in animal inoculated with one , two or three dose of mixed antigens (320 , 640 and 1280) respectively when it compared with animals inoculated with corresponding doses of AKL antigen (80 , 160 and 320) respectively. While the minimum level of antibody titers were observed in ani
... Show MoreConstruction projects are characterized as projects with multi phases and activities, complex, unique, and have many different parties and stakeholders. Risks could appear at one or more of the construction project stages and may affect the achievement of project objectives. Therefore, one of the key elements in the planning phase of any project is the risk management process (RMP). This study attempts to understand the terminology of risk in general, risk management, and response to risk in particular. This study is mainly a review of thirty-eight studies that have been published between 1997 and 2020 that demonstrate the importance of the crucial phase of risk response from the risk management process and its impact on
... Show MoreThis aim research of this discussion impact of investment in human capital dimensions (training, education, knowledge management, skills development) and its components (knowledge, skills, abilities, value) with the Office of the Inspector General's staff - Ministry of Culture in Iraq, has depended questionnaire as a tool in the collection data and information ,subjected to a measure of validity and reliability, and distributed to a sample of (63) individuals were distributed in positions (director, director of the Division of employees) have been analyzed data search using ready-statistical software (SPSS) the used hypothesis testing and correlati
... Show More