Preferred Language
Articles
/
jkmc-261
Measurement of plasma fibrinogen and D-dimer in a sample of Iraqi patients with solid malignant tumors
...Show More Authors

Background: Multifactor affect the pathogenesis of thrombosis in solid malignancy; however, a significant role is attributed to the cancer cells ability to interact with and activate the host hemostatic system. [1] 

Hemostasis is highly correlated to tumor growth, angiogenesis and metastasis, modulation of these pathways reflects interesting and promising treatment options in the future. [1]

Most patients with cancer frequently suffer from chronic compensated DIC and have abnormal laboratory coagulation tests without clinical manifestations of thrombosis, which is a subclinical hypercoagulable state that can be detected by varying degrees of activation of blood clotting. The results of laboratory tests in these patients reflect continuous fibrin formation and lysis during the course of malignancy. [1]

Aim of study: To study the effect of solid malignant tumors on blood coagulation via measurements of plasma fibrinogen and D-dimer.

Subjects and methods: Thirty patients (9 males and 21 females) attending the oncology consultatory out-patient clinic at Baghdad Teaching Hospital/ Medical City were randomly selected and included in this study.

These patients were newly diagnosed as having malignant solid tumors depending on histopathological reports from private and governmental sectors.

All the laboratory tests were done at the hematology and biochemistry departments of Teaching Laboratories/ Medical City.

Results: Plasma fibrinogen level was significantly higher in patients group rather than control group (3.863 ±0.706) Vs (2.497±0.457 g/L} respectively, (P-value 0.001).The mean value of factor VIII activity was {181% ±58.4)and (99.3% ±11.1)for patient and control groups respectively, the P-Value was significant ( > 0.001 ).D-dimer was negative for all members of control group, for patients group ( 66.7 %) of them showed positive D-dimer and (33.3)were negative for D-dimer ,P-value was significant ( >0.001 ). Conclusions: There was increase in plasma fibrinogen level and positive D-dimer in cancer patients compared to the control group reflecting subclinical thrombophilia and higher risk of VTE in patients with solid tumors due to activation of prothrombotic and fibrinolytic pathways by malignant cells which is vital for the use of primary prophylaxis by anticoagulants.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Jun 13 2024
Journal Name
Al-rafidain Journal Of Medical Sciences ( Issn 2789-3219 )
Association of the MDR1 Variants (rs2032582 and rs2032583) with Steroid Response in Iraqi Children with Idiopathic Nephrotic Syndrome
...Show More Authors

Background: Several studies linked the development of steroid-resistant nephrotic syndrome (SRNS) to genetic variations in the multidrug resistance 1 (MDR1) gene, though a disparity in findings was underlined among children with different ethnic origins. Objective: This study examined the relationship between MDR1 variants (rs2032582 and rs2032583) and the risk of developing SRNS in Iraqi patients with idiopathic nephrotic syndrome (INS). Methods: This case-control study included children with steroid-sensitive INS (SSNS; n=30) and SRNS (n=30) from the Babylon Hospital for Maternity and Pediatrics. Sanger sequencing was used to determine the participants’ genotypes. Results: The rs2032582 genotypes and alleles were not associated

... Show More
View Publication
Scopus Crossref
Publication Date
Sun Jun 12 2011
Journal Name
Baghdad Science Journal
Measurement of Background Radioactivity in Sewage Sludge for Baghdad City Treatment Stations
...Show More Authors

Sewage sludge samples were collected from Al-rasafa and Al-karkh refinement stations which represent the main stations of Baghdad city. Samples were collected from all treatment stages: before, after, and during refinement processes. The High Purity Germanium Coaxial Detector system with energy resolution 1.8 keV for energy line 1333 keV of Co – 60 radioactive sources was used to measure radioactivity from both natural and artificial sources. GENIE – 2000 analysis the results statistically and qualitatively. The results showed that all sewage sludge samples exhibited natural radioactive level and sometimes less than the international regular standards, but Al–Karkh station showed increment in radioactive levels than Al– Rasa

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Nov 01 2020
Journal Name
Journal Of Physics: Conference Series
Measurement of Natural Radioactivity in different cigarettes samples by using (HPGe) detector
...Show More Authors
Abstract<p>Twelve samples of cigarettes have been collected from local markets of different types and origins by using (HPGe) detector, and measurement of the specific activity for series U<sup>238</sup> and series Th<sup>232</sup> in addition to K<sup>40</sup> in order to estimate the health risk of cigarettes their by smokers, the results shown that highest specific activity value were be (12. 8±6. 3 Bq/kg, 8. 41±5. 8 Bq/kg, 125. 16±58. 3 Bq/kg), respectively, in the sample (MAC) MacBeth type cigarettes in Brazilian origin, this paper reports data such as (specific activity of K<sup>40</sup>, series U<sup>238</sup>, series Th<sup>232</sup></p> ... Show More
View Publication
Crossref
Publication Date
Sat Jan 01 2011
Journal Name
Iraqi Journal Of Physics
Measurement of Background Radioactivity in Baghdad's Main Water Supply Stations: Sediment Samples
...Show More Authors

Sediment samples were collected from main water processing and supply plants in Baghdad, and tested for radioactivity from both natural and artificial sources. These stations are: East Dijla (Tigris), Al-Kadisia, Al-Karama, Al-Rasheed, Al-Sader, Al-Wathba, and Al-Wihda supply stations. Qualitative measurements were made, and the results showed that most sediments exhibited natural radioactive level and sometimes less than the international regular standards. Specially, K-40 and Ra-226 results were much less than the standards for radioactive concentrations. Ac-228 concentration was found rather than Th-232 (in Al-Sader and Al-Wihda samples) but with low concentrations of about 10-15 Bg/kg and detection confidence ~45% , and Ce-141 and Be

... Show More
View Publication Preview PDF
Publication Date
Wed Feb 20 2019
Journal Name
Iraqi Journal Of Physics
Measurement of radon concentrations for some houses in Al-Najaf city /Iraq
...Show More Authors

    Measurement of radon concentration level was carried out in 40 houses in Al – Najaf city during summer season of 2012. Long term measurement of indoor of old building radon concentrations have been taken, using a previously calibrated passive diffusion dosimeters containing CR – 39 solid state nuclear track detectors which are very sensitive for alpha particles. The measurement of the indoor radon concentration obtained in summer in these regions ranged from 11.654±4.216 Bq.m-3 to 53.610±8.777 Bq.m-3. The results were within universally permitted levels.     

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Feb 14 2022
Journal Name
Journal Of Educational And Psychological Researches
The Linguistic and Conceptual Equivalence of Conner’s Revised Scales When Applied on a Sudanese Sample
...Show More Authors

This study investigates the Linguistic and Conceptual equivalence of Conner’s Revised Scales when applied on a Sudanese sample. Sudanese parents and teachers completed behavior-rating scales on a stratified sample of 200 children. These instruments were based on Conner’s parent -48 and teacher-28 questionnaires. Following a reliable translation into Sudanese Arabic the test-retest reliability of the items and the internal consistency of the original Conner’s' revised scales were explored. The associations between scale scores and between parents and teachers scores were also examined. Both instruments displayed good reliability and the original Conners scales had satisfactory internal consistency. The inter-correlation sugg

... Show More
View Publication Preview PDF
Publication Date
Tue Sep 11 2018
Journal Name
Iraqi Journal Of Physics
Measurement of Percentage Depth Dose (PDD) for 6 MeV in water phantom and homogenous actual planning
...Show More Authors

Radiotherapy is the branch of clinical medicine concerned with the application of ionizing radiation in the treatment of disease. And it is used to killing of cancer cells in a tissue using ionizing radiation while keeping the sparing of healthy cells at acceptable level. X-ray beams are used to deposit absorbed dose at depth within a patient at the site of the tumor. The aim of this work is studying the relationship between the depth dose and the field size in water phantom and homogenous actual planning. In our work, the dose distribution at different depths (zero-18 cm) deep at1cm interval treated with field size (10×10 and 20×20) cm2 were studied.
Results show that high similarity between water phantom and actual planning for th

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jun 28 2018
Journal Name
Iraqi Journal Of Physics
Measurement of Percentage Depth Dose (PDD) for 6 MeV in water phantom and homogenous actual planning
...Show More Authors

Radiotherapy is the branch of clinical medicine concerned with the application of ionizing radiation in the treatment of disease. And it is used to killing of cancer cells in a tissue using ionizing radiation while keeping the sparing of healthy cells at acceptable level. X-ray beams are used to deposit absorbed dose at depth within a patient at the site of the tumor. The aim of this work is studying the relationship between the depth dose and the field size in water phantom and homogenous actual planning. In our work, the dose distribution at different depths (zero-18 cm) deep at1cm interval treated with field size (10×10 and 20×20) cm2 were studied. Results show that high similarity between water phantom and actual planning for

... Show More
Publication Date
Sat Sep 11 2021
Journal Name
Biochemical And Cellular Archives
Genotyping of IL13 -1024 (CT) gene among Iraqi Thyoid Goiter patients
...Show More Authors

This study dealt with IL-13 1024 (C/T) gene genotyping among patients with Thyroid goiter in Iraq. Forty blood samples from patients with Thyroid goiter were collected and compared with 30 healthy persons as controls. The genotyping results of IL-13 1024 (C/T) gene using ARMS-PCR revealed presence TT, CC and CT genotypes beside T and C alleles. The T allele and TT genotype frequency were higher in Thyroid goiter patients compared to the same genotype and allele in healthy persons (P = 0.060). These increasing results were related with increasing risk factor of Thyroid goiter (odds ratio [OR] 2.15; 95% confidence interval [CI] 0.99–71.4). No significant differences between genotypes for Thyroid goiter patients and controls were revealed by

... Show More
View Publication Preview PDF
Publication Date
Tue May 11 2021
Journal Name
Egyptian Journal Of Medical Human Genetics
Molecular analysis of CFTR gene mutations among Iraqi cystic fibrosis patients
...Show More Authors
Abstract<sec> <title>Background

Cystic fibrosis (CF) is an autosomal recessive multisystem disease that results from mutation(s) of the cystic fibrosis transmembrane conductance regulator (CFTR) gene. More than 2100 mutations and polymorphisms have been reported in this gene so far. Incidence and genotyping of CF are under-identified in Iraq. This study aims to determine the types and frequencies of certain CFTR mutations among a sample of Iraqi CF patients. Two groups of patients were included: 31 clinically confirmed CF patients in addition to 47 clinically suspected patients of CF. All confirmed pa

... Show More
View Publication
Scopus (7)
Crossref (5)
Scopus Clarivate Crossref