Background : The number of primary hip arthroplasty is growing with every passing year. At present this surgical operation has no equal in the rate of yielding good results. Despite the fact that in many cases in the long term after surgery radiolucent lines around the cup are observed, the clinical outcomes remain satisfactory.
Aim of the study :To study the clinical and radiological manifestations of the aseptic loosening of the endoprosthesis
Methods: This is a prospective study based on an analysis of diagnostic findings of 51 patients with aseptic loosening of hip joint components, aged 30 to 84 years. We depend for diagnosis of a septic losing by both clinical evaluation and X-ray assessment Results:The majority of clinical and radiological evidence of aseptic loosening appear after three years (47%).All our patients had a pain syndrome of varying intensity, with (43.2%) used a walking-stick. Shortening limb from 1 to 7 cm was found in 43 patients 85.2%.
The aseptic losing are common in cementless hip prosthesis especially in femoral stem part of prosthesus 53.9% versus 25.6% in cemented type,
Revision surgery for primary hip prosthesis occur mainly for femoral stem involve 49% while other 25.5% involve both acetabular cup and femoral stem, while the rest of patient(25.5%) involve revision of acetabular cup only. Discussion :At present this surgical operation has no equal in the rate of yielding good results. The lifetime of the majority of artificial joints does not exceed 15 years mainly due to aseptic loosening of one or both endoprosthetic components There are many causes of aseptic instability: substandard surgical technique, unwarranted extension of the indications for arthroplasty, inappropriate choice of the prosthesis dimension type, incorrect installation of components, reaction to the massive foreign body and the development of synovial-like membrane on the metal-bone interface .
As a rule, early instability within 1 year was associated with defects in the operative techniques, from 1 to 3 years mostly due to the wrong selection of the type of primary endoprosthesis while more than 3 years period, the instability was caused by two reasons: excessive load on the operated extremity or traumas and the rapid wear of plastic with large areas of osteolysis due to the high loads or inaccurate positioning of the prosthetic cup.
Conclusions: X-ray examination is the fundamental for diagnosing of aseptic loosening of hip endoprosthesis , and improved surgical techniques, the proper selection of the type of prosthesis are the keys for reduction of risk of aseptic loosening
Objectives: The demand for orthodontic treatment is nowadays increasing significantly for aesthetic improvement and to correct various kinds of malocclusion, yet the prolonged treatment time remains the main obstacle. This review aimed to demonstrate various orthodontic techniques and highlight the evidence-based successful approaches used for acceleration of orthodontic tooth movement. Materials and Methods: Data and sources of information pertaining to accelerated orthodontic tooth movement premised on English-written articles were searched using electronic databases including Google Scholar, Scopus, PubMed and MEDLINE. Results: This review demonstrated the availability of different surgical and non-surgical methods to enhance tooth movem
... Show MoreThe general aim of an experimental design in this paper was to estimate the different treatments effects on the responses by statistical methods. The estimates must be averting biases and the random errors minimized as much as possible. We used multivariate analysis of variance (MANOVA) to analyze design of experiments for several responses. In this paper, we provided three fertilizers (mineral, humic, micro-elements) applied on Yellow Maize experiment. This experiment was conducted by completely randomized design (CRD). We tested four responses (Chlorophyll in paper, total ton / ha, paper area / cm2 and plant height / cm) together to find significant test between them. The partial correlations are between Chlorophyll in paper and total ton
... Show MoreResults of a study of alloys and films with various Pb content have been reported and discussed. Films of of thickness 1.5
This research deals with the form of the physical identity which is concerned with the features and characteristics that distinguish the shape of the city from other existing cities and reveal its similarity with the self (itself) and objective difference with others. Accordingly, these features must be sophisticated and variable resulting the shape of the city, while preserving the continuity of time, and eventually leads to the emergence of the whole shape. Physical identity is conceptually equivalent with the terms "personality" and "sense of place". The research determined the criteria for evaluating the physical identity as follows:
... Show MoreTwo specie's of terrnitls are described as new to science from Iraq Amitermes corpnlentus sp. n. and Anacanthotermes savvensis sp. n., with two figures.
Sixty samples of commercially available contact lens solutions were collected from students at the Pharmacy College/Baghdad University. The types of lenses used varied from medical to cosmetic. They were cultured to diagnose any microbial contamination within the solutions. Both used and unused solutions were subject for culturing. Thirty six (60%) used samples showed bacterial growth, fungal growth was absent. Pseudomonas aeruginosa accounts for the highest number of isolates (25%) followed by E. coli (21%), Staphylococcus epidermidis (6.6%), Pseudomonas fluorescence (5%) and Proteus mirabilis (1.6%) respectively. Only one (1) unused (sealed) sample showed growth of P. fluorescence.
... Show MoreAim: To evaluate the wettability and microhardness of Zirconium (ZrO2) dental material when coated with different concentrations of Faujasite. Materials and methods: 30 circular disks produced from ZrO2, then each group is classified into 10 control groups, 10 coated groups with 3% Faujasite, and 10 coated groups with 7% faujasite by electro-spun tool to study variable properties in hardness and water contact angle of implant materials. Results: This study stated the high hardness in 7% of faujasite concentration for ZrO2, in addition, the contact angle decreased gradually until reach 0 ᵒ in 7% concentration of faujasite with ZrO2 Conclusion: Water contact angle (WCA) declined till disappeared in (7% wt.) of faujasite coated with the Z
... Show MoreThis study investigates the ionic conduction dependence on the size of alkaline cations in gel polymer electrolytes based on double iodide can enhance by incorporating a salt having a bulky cation.
... Show More