Background : The number of primary hip arthroplasty is growing with every passing year. At present this surgical operation has no equal in the rate of yielding good results. Despite the fact that in many cases in the long term after surgery radiolucent lines around the cup are observed, the clinical outcomes remain satisfactory.
Aim of the study :To study the clinical and radiological manifestations of the aseptic loosening of the endoprosthesis
Methods: This is a prospective study based on an analysis of diagnostic findings of 51 patients with aseptic loosening of hip joint components, aged 30 to 84 years. We depend for diagnosis of a septic losing by both clinical evaluation and X-ray assessment Results:The majority of clinical and radiological evidence of aseptic loosening appear after three years (47%).All our patients had a pain syndrome of varying intensity, with (43.2%) used a walking-stick. Shortening limb from 1 to 7 cm was found in 43 patients 85.2%.
The aseptic losing are common in cementless hip prosthesis especially in femoral stem part of prosthesus 53.9% versus 25.6% in cemented type,
Revision surgery for primary hip prosthesis occur mainly for femoral stem involve 49% while other 25.5% involve both acetabular cup and femoral stem, while the rest of patient(25.5%) involve revision of acetabular cup only. Discussion :At present this surgical operation has no equal in the rate of yielding good results. The lifetime of the majority of artificial joints does not exceed 15 years mainly due to aseptic loosening of one or both endoprosthetic components There are many causes of aseptic instability: substandard surgical technique, unwarranted extension of the indications for arthroplasty, inappropriate choice of the prosthesis dimension type, incorrect installation of components, reaction to the massive foreign body and the development of synovial-like membrane on the metal-bone interface .
As a rule, early instability within 1 year was associated with defects in the operative techniques, from 1 to 3 years mostly due to the wrong selection of the type of primary endoprosthesis while more than 3 years period, the instability was caused by two reasons: excessive load on the operated extremity or traumas and the rapid wear of plastic with large areas of osteolysis due to the high loads or inaccurate positioning of the prosthetic cup.
Conclusions: X-ray examination is the fundamental for diagnosing of aseptic loosening of hip endoprosthesis , and improved surgical techniques, the proper selection of the type of prosthesis are the keys for reduction of risk of aseptic loosening
Bipedal robotic mechanisms are unstable due to the unilateral contact passive joint between the sole and the ground. Hierarchical control layers are crucial for creating walking patterns, stabilizing locomotion, and ensuring correct angular trajectories for bipedal joints due to the system’s various degrees of freedom. This work provides a hierarchical control scheme for a bipedal robot that focuses on balance (stabilization) and low-level tracking control while considering flexible joints. The stabilization control method uses the Newton–Euler formulation to establish a mathematical relationship between the zero-moment point (ZMP) and the center of mass (COM), resulting in highly nonlinear and coupled dynamic equations. Adaptiv
... Show MoreMultiple sclerosis (MS) is a chronic, inflammatory, immune mediated disease of the central nervous system, mostly affecting young adults with mean age of 30 years, twice as high in women compared to men. The etiology of MS is not fully elucidated. MS symptoms are directly related to demyelination and axonal loss, along with other psychological symptoms, can result in functional limitations, disability and reduced quality of life (QoL). The QoL assessments in patients with a chronic disease may contribute to improving treatment and could even be of prognostic value. The goals of this study were to compare the QoL of Iraqi patients with relapsing remitting multiple sclerosis (RRMS),using three different diseas
... Show MoreA chemometric method, partial least squares regression (PLS) was applied for the simultaneous determination of piroxicam (PIR), naproxen (NAP), diclofenac sodium (DIC), and mefenamic acid (MEF) in synthetic mixtures and commercial formulations. The proposed method is based on the use of spectrophotometric data coupled with PLS multivariate calibration. The Spectra of drugs were recorded at concentrations in the linear range of 1.0 - 10 μg mL-1 for NAP and from 1.0 - 20 μg mL-1 for PIR, DIC, and MEF. 34 sets of mixtures were used for calibration and 10 sets of mixtures were used for validation in the wavelength range of 200 to 400 nm with the wavelength interval λ = 1 nm in methanol. This method has been used successfully to quant
... Show MoreThe intelligent buildings provided various incentives to get highly inefficient energy-saving caused by the non-stationary building environments. In the presence of such dynamic excitation with higher levels of nonlinearity and coupling effect of temperature and humidity, the HVAC system transitions from underdamped to overdamped indoor conditions. This led to the promotion of highly inefficient energy use and fluctuating indoor thermal comfort. To address these concerns, this study develops a novel framework based on deep clustering of lagrangian trajectories for multi-task learning (DCLTML) and adding a pre-cooling coil in the air handling unit (AHU) to alleviate a coupling issue. The proposed DCLTML exhibits great overall control and is
... Show MoreIn this work, effects of using different evaporative cooling pads (ECPs) on the energetic and exergetic efficiency of a direct evaporative air cooler (DEAC) have been theoretically and experimentally investigated. Three types of ECPs were used, i.e., honeycomb cellulose cooler pad (HCCP), shading-cloth cooler pad (SCCP), and aspen wood wool cooler pad (AWWCP). For SCCP and AWWCP, a 3-cm pad thickness was used, while for the HCCP, three different values of pad thickness were used, i.e., 3, 5, and 7 cm. Tests were carried out using air velocities of 8, 14, and 19 m/s, measured at the DEAC outlet. Engineering equation solver (EES) used for performing the required calculations of the various parameters affecting the thermal performance of the D
... Show More