Background : The number of primary hip arthroplasty is growing with every passing year. At present this surgical operation has no equal in the rate of yielding good results. Despite the fact that in many cases in the long term after surgery radiolucent lines around the cup are observed, the clinical outcomes remain satisfactory.
Aim of the study :To study the clinical and radiological manifestations of the aseptic loosening of the endoprosthesis
Methods: This is a prospective study based on an analysis of diagnostic findings of 51 patients with aseptic loosening of hip joint components, aged 30 to 84 years. We depend for diagnosis of a septic losing by both clinical evaluation and X-ray assessment Results:The majority of clinical and radiological evidence of aseptic loosening appear after three years (47%).All our patients had a pain syndrome of varying intensity, with (43.2%) used a walking-stick. Shortening limb from 1 to 7 cm was found in 43 patients 85.2%.
The aseptic losing are common in cementless hip prosthesis especially in femoral stem part of prosthesus 53.9% versus 25.6% in cemented type,
Revision surgery for primary hip prosthesis occur mainly for femoral stem involve 49% while other 25.5% involve both acetabular cup and femoral stem, while the rest of patient(25.5%) involve revision of acetabular cup only. Discussion :At present this surgical operation has no equal in the rate of yielding good results. The lifetime of the majority of artificial joints does not exceed 15 years mainly due to aseptic loosening of one or both endoprosthetic components There are many causes of aseptic instability: substandard surgical technique, unwarranted extension of the indications for arthroplasty, inappropriate choice of the prosthesis dimension type, incorrect installation of components, reaction to the massive foreign body and the development of synovial-like membrane on the metal-bone interface .
As a rule, early instability within 1 year was associated with defects in the operative techniques, from 1 to 3 years mostly due to the wrong selection of the type of primary endoprosthesis while more than 3 years period, the instability was caused by two reasons: excessive load on the operated extremity or traumas and the rapid wear of plastic with large areas of osteolysis due to the high loads or inaccurate positioning of the prosthetic cup.
Conclusions: X-ray examination is the fundamental for diagnosing of aseptic loosening of hip endoprosthesis , and improved surgical techniques, the proper selection of the type of prosthesis are the keys for reduction of risk of aseptic loosening
In this paper investigate the influences of dissolved CO2/H2S gases, crude oil velocity and temperature on the rate of corrosion of crude oil transmission pipelines of Maysan oil fields southern Iraq. The Potentiostatic corrosion test technique was conducted into two types of carbon steel pipeline (materials API 5L X60 and API 5L X80). The computer software ECE electronic corrosion engineer was used to predict the influences of CO2 partial pressure, the composition of crude oil, flow velocity of crude oil and percentage of material elements of carbon steel on the rate of corrosion. As a result, the carbon steel API 5L X80 indicates good and appropriate resistance to corrosion compared to carbon steel API
... Show MoreAAA AL-NUAIMY, MH ABDLL-ABASS, Iraqi Journal of Agricultural Sciences, 2007
A field experiment was conducted during the spring season 2020 in Karbala proving/ Al-Sharia Distrit, located at latitude N 32° 42' 13.8" and longitude E 43° 54' 36.6" and at an altitude of 27 m above sea level. The experiment included a study of two factors: the first, Irrigation Interval, three treatments were used: irrigation treatment every 2 days, Irrigation treatment every 4 days, and Irrigation treatment every 6 days. The second factor is the addition of soil conditioners, in which four treatments were used: the control treatment without any addition, the treatment of adding bio-organic fertilizers, the treatment of adding water-conserving technology (polymer), and the treatment of adding water-conserving technology + fertilizers O
... Show More
Background: Polymethylmethacrylate (PMMA) is the most ‎commonly used mâ€aterial in denture construction. This material is ‎far from ideal in fulfilling the‎ mechanical requirements, like low impact and transverse strength and poor thermal conductivity are present in this material. The purpose of this study was to study the effect of addition a composite which include 1%wt silanized silicone dioxide nano fillers (SiO2) and 1wt% oxygen plasma treated polypropylene fiber (PP) on some properties of heat cured acrylic resin denture base material (PMMA). Materials and methods: One hundâ€red (100) prepared specimens were divided into five groups according to the tests, each group consisted of 20 specimens and t
Background: Denture fracture is one of the most common problems encountered by the patients and prosthodontists. The objective of present study was to evaluate the transverse strength of nylon denture base resin repaired by using conventional heat polymerized, autopolymerized and visible light cure {VLC} resins, surface treatment that used for repair and adjustment of insufficient nylon denture bases and in case of addition of artificial teeth. As these corrective procedures are common chair side procedures in dental clinic. Materials and methods: One hundred twenty nylon specimens were prepared by using metal patterns with dimension of (65x10x2.5 mm) length, width, and thickness respectively for transverse strength test while for tensile b
... Show MoreA new series of metal ions complexes of VO(II), Cr(III), Mn(II), Zn(II), Cd(II) and Ce(III) have been synthesized from the Schiff bases (4-chlorobenzylidene)-urea amine (L1) and (4-bromobenzylidene)-urea amine (L2). Structural features were obtained from their elemental microanalyses, magnetic susceptibility, molar conductance, FT-IR, UV–Vis, LC-Mass and 1HNMR spectral studies. The UV–Vis, magnetic susceptibility and molar conductance data of the complexes suggest a tetrahedral geometry around the central metal ion except, VOII complexes that has square pyramidal geometry, but CrIII and CeIII octahedral geometry. The biological activity for the ligand (L1) and its Vanadium and Cadmium complexes were studied. Structural geometries of com
... Show More