Background: Coronary artery disease remains the main cause of death despite several preventive programs. Epicardial adipose tissue is a visceral fat depot of the heart located along the large coronary arteries and on the surface of ventricles and apex. Intima media thickness is commonly recognized as the initial stage in the development of atherosclerosis. The development of ultrasound machines, advances in echocardiographic devices and high resolution transducers facilitate comprehensive analysis of epicardial fat thickness (EFT) and carotid –intima media thickness (C-IMT).
Aim: To investigate the relationship of echocardiographic epicardial fat thickness (EFT) and carotid –intima media thickness (C-IMT) with the severity of coronary artery disease.
Methods: A cross sectional multicenter diagnostic accuracy study carried out at Ibn Al-Nafis Cardiovascular Hospital, Ibn Al- Bitar Cardiology Center and Ghazi Al-Hariri Hospital –Iraqi Center for Cardiology during the period between October 2016 and May 2017 assessing. History regarding demographic data and risk factors was taken. Two dimensional transthoracic echocardiographic measurements were done. EFT was measured from parasternal long axis view perpendicular to the right ventricular free wall. C-IMT was measured according to that recommended by the American society of echocardiography (ASE).
Results: The current study demonstrated that the EFT has a direct and significant correlation with the number of involved vessels (P value ˂ 0.001, r= 0.770). The validity of EFT to discriminate between multiple vessels disease and no vessel involvement is excellent (AUC= 0.984, cut point > 8mm, sensitivity=92.9%, specificity= 93.3%). There is inverse and significant correlation between ejection fraction (EF) and three vessels disease (P value ˂ 0.001, r= -0.507). Also there is a direct and significant correlation between C-IMT and severity of CAD. ROC analysis for validity of C-IMT to discriminate between multiple vessels disease and no vessel involvement is excellent (AUC= 0.961, cut point > 1.04mm, sensitivity=92.9%. specificity=86.7%). C-IMT is fair to discriminate between single vessel disease and no vessel involvement (AUC=0.738, cut point ˃ 0.84mm, sensitivity 100%), so if correlated with age, C-IMT above 0.84 can be used as a cut off point for the prediction of CAD. Finally, EFT and C-IMT are more likely to reflect severity of CAD than their ratio.
Conclusions: C-IMT and EFT are simple and reproducible parameters that can be used as a screening tool for the presence and severity of CAD especially before symptoms appearance in high risk patients
The research problem is dedicated to investigate reservoirs irrational economic behavior adopted by the ruling elites in developing countries about the investment methodology of human capital and operating policies is based on the terms of reference of economic theory and standards governing the market, which led to a chronic structural imbalance in the workforce structure and lack of consistency with different production structure, in turn, which had a reported effects in the emergence of the phenomenon of unemployment and that they involved a certain privacy, as has become the issues of unemployment and employment in the various countries of the world are issues more important due to the presence of large numbers of the workforce in th
... Show MoreFullerene nanotube was synthesized in this research by pyrolysis of plastic waste Polypropylene (PP) at 1000 ° C for two hours in a closed reactor made from stainless steel using molybdenum oxide (MoO3) as a catalyst and nitrogen gas. The resultant carbon was purified and characterized by energy dispersive X-ray spectroscopy (EDX), X-ray powder diffraction (XRD). The surface characteristics of C60 nanotubes were observed with the Field emission scanning electron microscopy (FESEM). The carbon is evenly spread and has the highest concentration from SEM-EDX characterization. The result of XRD and FESEM shows that C60 nanotubes are present in Nano figures, synthesized at 1000 ° C and with pyrolysis tempera
... Show MoreBlood samples of One hundred and twenty patients from different hospitals in Baghdad infected with hydatidosis in different sites of the body (Liver, Lung, multiorgans and kidney) were collected for this study. On the other hand, 30 healthy individuals were included as a control group. This study was conducted to evaluate the effect of this disease on the serum protein profile of the patients using electrophoresis. The results revealed four different protein banding patterns with difference in number of bands and their molecular weights in comparison to the control group, and these differences depended on the site of infection. However the data showed a presence of the same band in all patients with different site of infection.
Rheumatoid arthritis is one of the common chronic disease, which lead to great disability and chronic pain, and has a main adverse economic and social effect upon patients. The reason for the addition of quality of life as a pointer for health outcome result is attributed to the affectability of this measure for the evaluation of patient's health status after taken treatment and its health outcome. The purpose of the current study was to assess quality of life among a sample of Iraqi patients with rheumatoid arthritis and to determine the possible association between health’s related quality of life and some patient-certain factors. This study is a cross-sectional study carried out on 250 already diagnosed rheumatoid arthritis pat
... Show MoreThis work deals with determination of optimum conditions of direct diffusion bonding welding of austenitic stainlesssteel type AISI 304L with Oxygen Free High Conductivity (OFHC) pure copper grade (C10200) in vacuum atmosphere of (1.5 *10-5 mbr.). Mini tab (response surface) was applied for optimizing the influence of diffusion bonding parameters (temperature, time and applied load) on the bonding joints characteristics and the empirical relationship was evaluated which represents the effect of each parameter of the process. The yield strength of diffusion bonded joint was equal to 153 MPa and the efficiency of joint was equal to 66.5% as compared with hard drawn copper. The diffusion zone reveals high microhardness than coppe
... Show MoreThe spray quality of two spraying agents with different physical properties was investigated under laboratory conditions to find whether the measurement of deposited drops could be affected by spraying those agents. The first spraying agent Moddus, which is a plant growth regulator, has a surface tension of 28 mN m-1 with almost half the value of the second spraying agent Kelpak (58 mN m-1). A mini boom sprayer containing three flat fan nozzles (XR 11003) was used in the test with three traveling speeds (4.74, 5.42 and 8.13 km. h-1). The test was performed to evaluate the quality of spray drops (spray coverage, spray density and stains diameter) after they were deposited on water sensitive papers (WSP). The results showed a higher ability o
... Show MoreGurney flap (GF) is well-known as one of the most attractive plain flaps because of the simple configuration and effectiveness in improving the lift of the airfoil. Many studies were conducted, but the effects of GF on the various airfoil types need to be further investigated. This study aimed to clarify the effect of GF in the case of the supercritical airfoil RAE2822. This research includes a steady, two-dimensional computational investigation carried out on the supercritical airfoil type RAE-2822 to analyze Gurney flap (GF) effects on the aerodynamic characteristics of this type of airfoil utilizing the Spalart-Allmaras turbulence model within the commercial software Fluent. The airfoil with the Gurney flap was analyz
... Show MoreSome coordination complexes of Co(??), Ni(??), Cu(??), Cd(??) and Hg(??) are reacted in ethanol with Schiff base ligand derived from of 2,4,6- trihydroxybenzophenone and 3-aminophenol using microwave irradiation and then reacted with metal salts in ethanol as a solvent in 1:2 ratio (metal: ligand). The ligand [H4L] is characterized by FTIR, UV-Vis, C.H.N, 1H-NMR,13C-NMR, and mass spectra. The metal complexes are characterized by atomic absorption, infrared spectra, electronic spectra, molar conductance, (C.H.N for Ni(??) complex) and magnetic moment measurements. These measurements indicate that the ligand coordinates with metal (??) ion in a tridentate manner through the nitrogen and oxygen atoms of the ligand, octahedral structures
... Show More