Background: Coronary artery disease remains the main cause of death despite several preventive programs. Epicardial adipose tissue is a visceral fat depot of the heart located along the large coronary arteries and on the surface of ventricles and apex. Intima media thickness is commonly recognized as the initial stage in the development of atherosclerosis. The development of ultrasound machines, advances in echocardiographic devices and high resolution transducers facilitate comprehensive analysis of epicardial fat thickness (EFT) and carotid –intima media thickness (C-IMT).
Aim: To investigate the relationship of echocardiographic epicardial fat thickness (EFT) and carotid –intima media thickness (C-IMT) with the severity of coronary artery disease.
Methods: A cross sectional multicenter diagnostic accuracy study carried out at Ibn Al-Nafis Cardiovascular Hospital, Ibn Al- Bitar Cardiology Center and Ghazi Al-Hariri Hospital –Iraqi Center for Cardiology during the period between October 2016 and May 2017 assessing. History regarding demographic data and risk factors was taken. Two dimensional transthoracic echocardiographic measurements were done. EFT was measured from parasternal long axis view perpendicular to the right ventricular free wall. C-IMT was measured according to that recommended by the American society of echocardiography (ASE).
Results: The current study demonstrated that the EFT has a direct and significant correlation with the number of involved vessels (P value ˂ 0.001, r= 0.770). The validity of EFT to discriminate between multiple vessels disease and no vessel involvement is excellent (AUC= 0.984, cut point > 8mm, sensitivity=92.9%, specificity= 93.3%). There is inverse and significant correlation between ejection fraction (EF) and three vessels disease (P value ˂ 0.001, r= -0.507). Also there is a direct and significant correlation between C-IMT and severity of CAD. ROC analysis for validity of C-IMT to discriminate between multiple vessels disease and no vessel involvement is excellent (AUC= 0.961, cut point > 1.04mm, sensitivity=92.9%. specificity=86.7%). C-IMT is fair to discriminate between single vessel disease and no vessel involvement (AUC=0.738, cut point ˃ 0.84mm, sensitivity 100%), so if correlated with age, C-IMT above 0.84 can be used as a cut off point for the prediction of CAD. Finally, EFT and C-IMT are more likely to reflect severity of CAD than their ratio.
Conclusions: C-IMT and EFT are simple and reproducible parameters that can be used as a screening tool for the presence and severity of CAD especially before symptoms appearance in high risk patients
Objective: To assess the nutritional status of hemodialysis patients.
Methodology: A descriptive quantitative cross sectional study was effectuated in hemodialysis centers from
February 2011 to September 2011. A purposive "non-probability" sample of (70) male and female hemodialysis
patients in al-Najaf al-Ashraf Governorate from those who have spent more than six months on maintenance
hemodialysis schedule. Data collected through using of a well-designed questionnaire consist of five parts, part
one consists of sociodemographic contain (9) items, and part two consists of medical data contain (8) items, and
part three consists of health and nutrition behavior contain (12) items plus (8) items of anthropometric
measur
This research dealt with desalting of East Baghdad crude oil using pellets of either anionic, PVC, quartz, PE, PP or
nonionic at different temperature ranging from 30 to 80 °C, pH from 6 to 8, time from 2 to 20 minutes, volume percent
washing water from 5 to 25% and fluid velocity from 0.5 to 0.8 m/s under voltage from 2 to 6 kV and / or using additives
such as alkyl benzene sulphonate or sodium stearate. The optimum conditions and materials were reported to remove
most of water from East Baghdad wet crude oil.
Ultrasound has been used as a diagnostic modality for many intraocular diseases, due its safety, low cost, real time and wide availability. Unfortunately, ultrasound images suffer from speckle artifact that are tissue dependent. In this work, we will offer a method to reduce speckle noise and improve ultrasound image to raise the human diagnostic performance. This method combined undecimated wavelet transform with a wavelet coefficient mapping function: where UDWT used to eliminate the noise and a wavelet coefficient mapping function used to enhance the contrast of denoised images obtained from the first component. This methods can be used not only as a means for improving visual quality of medical images but also as a preprocessing
... Show MoreEvaluation of Dot. ELISA test for Diagnosis Visceral Leishmaniasis in Infected Children
Sewage sludge samples were collected from Al-rasafa and Al-karkh refinement stations which represent the main stations of Baghdad city. Samples were collected from all treatment stages: before, after, and during refinement processes. The High Purity Germanium Coaxial Detector system with energy resolution 1.8 keV for energy line 1333 keV of Co – 60 radioactive sources was used to measure radioactivity from both natural and artificial sources. GENIE – 2000 analysis the results statistically and qualitatively. The results showed that all sewage sludge samples exhibited natural radioactive level and sometimes less than the international regular standards, but Al–Karkh station showed increment in radioactive levels than Al– Rasa
... Show MoreThe remediation oil production by matrix acidizing method on the well named "X" (for confidential reasons) is scrutinized in this paper. Initial production of 1150 bpd, production index of 2.8 STB/Psi/d and permeability of 150md, in 2018 two years down the lane this dropped to 450 bpd, production index 0.7 STB/Psi/d. The declined observed on the production index is trouble shouted and after elimination of (no completion damage/perforation damage), the skin is calculated by carrying out a well test (build-up test) whose extrapolation in excel over times gave us a skin of 40.The reservoir heterogeneity, containing >20% of feldspar, carbonates and paraffin’s guided thematrix acidizing design and treatment proposition to remedy thi
... Show MoreIn this work, radius of shock wave of plasma plume (R) and speed of plasma (U) have been calculated theoretically using Matlab program.
Background: Cervical ectopy advanced to erosion is one of the common conditions in gynecological and pathological study. It is considered as a physiologic condition resulting from columnar epithelium migration from the cervical canal into the vaginal portion of the cervix, in which no treatment for asymptomatic cervical ectropion can be given. Treatment can be accomplished via thermal cauterization (Electro cautery), Cryosurgery. CO2 laser therapy is another modality of treatment.
Objective: To study the effectiveness of CO2 laser therapy and evaluate it as a biomedical tool for the treatment of cervical ectropion. The study was done at Laser Medicine Research Clinic at the
... Show More