Preferred Language
Articles
/
jkmc-163
Tympanostomy Tube Complication in Otitis Media with Effusion
...Show More Authors

Background: Otitis media with effusion is characterized by accumulation of fluid in the middle ear in absence of acute inflammation and  it is the most common cause of  acquired hearing loss in children, and may  negatively affect language development failure of medical treatment of middle ear effusion frequently require myringotomy and tympanostomy tube insertion.

Objectives: To determine tympanostomy tube complications of tube in children with chronic otitis media with effusion who were treated with Shah Grommet tube insertion.

Methods: The Medical records of 162 ears of 87 children (52 male and 35 female) were reviewed respectively, the patients ages were between 3 to 16 years old (mean age =8.11 years), patient were followed for 6-66 months (mean 23.3) after tympanostomy tube insertion. Tube extrusion time was also reviewed in all patients, and the indication for surgery was chronic middle ear effusion.

Results: Otorrhea accured in nine ears (5.6%), granulation tissue was seen in 2 ears (1.2%), myringosclerosis in (34.6%) persistent perfor-ation (5.6%), atrophy (23.5%) retraction (16.7%) and medial displacement 1.2% the average extrusion time was 8.5 month ( ± 4.6).

Conclusions: complications of tympanostomy tube insertion are common and the most common are otorrhea myringosclerosis, atrophy but they are generally insignificant consequently in majority of these complications there is no need for management.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Nov 09 2021
Journal Name
Energies
Natural Convection Effect on Solidification Enhancement in a Multi-Tube Latent Heat Storage System: Effect of Tubes’ Arrangement
...Show More Authors

The solidification process in a multi-tube latent heat energy system is affected by the natural convection and the arrangement of heat exchanger tubes, which changes the buoyancy effect as well. In the current work, the effect of the arrangement of the tubes in a multi-tube heat exchanger was examined during the solidification process with the focus on the natural convection effects inside the phase change material (PCM). The behavior of the system was numerically analyzed using liquid fraction and energy released, as well as temperature, velocity and streamline profiles for different studied cases. The arrangement of the tubes, considering seven pipes in the symmetrical condition, are assumed at different positions in the system, i

... Show More
View Publication
Scopus (21)
Crossref (22)
Scopus Clarivate Crossref
Publication Date
Fri Mar 01 2024
Journal Name
International Communications In Heat And Mass Transfer
Accelerated charging of PCM in coil heat exchangers via central return tube and inlet positioning: A 3D analysis
...Show More Authors

View Publication
Scopus (35)
Crossref (32)
Scopus Crossref
Publication Date
Sun Sep 29 2024
Journal Name
International Journal Of Corrosion And Scale Inhibition
Using expired pharmaceutical Clotrimazole as a corrosion inhibitor for stainless steel in acidic media
...Show More Authors

View Publication Preview PDF
Scopus (2)
Scopus Crossref
Publication Date
Sun Sep 01 2024
Journal Name
Results In Engineering
Indole derivatives efficacy and kinetics for inhibiting carbon steel corrosion in sulfuric acid media
...Show More Authors

View Publication
Scopus (22)
Crossref (19)
Scopus Crossref
Publication Date
Mon Mar 01 2021
Journal Name
Journal Of Physics: Conference Series
Anti-Corrosive Substance as Green Inhibitor for Carbon Steel in Saline and Acidic Media
...Show More Authors

Ficus (FIC) leaf extract used as corrosion inhibitor for carbon steel alloy (C.S) in two corrosive environments (saline and acidic) with four concentrations (1, 2, 3 and 4 ppm) at varied temperature range between (298-328 K) using electrochemical polarization measurements. The importance of this work focused on the use the green chemistry that is far from the chemical materials effect. The results of polarization presented the FIC inhibitor consider a mixed type (anodic and cathodic) inhibitor. Tafel curve used to evaluate the corrosion inhibition activity. In a saline medium, the best inhibitor efficiency reaches to (87%) in 2 ppm and IE% reach to (99%) for HCl medium inhibited by 1ppm. Langmuir isotherm obeys the study by thermodynamic pa

... Show More
View Publication
Scopus (30)
Crossref (17)
Scopus Crossref
Publication Date
Sun Jun 20 2021
Journal Name
Baghdad Science Journal
A Word Cloud Model based on Hate Speech in an Online Social Media Environment
...Show More Authors

Social media is known as detectors platform that are used to measure the activities of the users in the real world. However, the huge and unfiltered feed of messages posted on social media trigger social warnings, particularly when these messages contain hate speech towards specific individual or community. The negative effect of these messages on individuals or the society at large is of great concern to governments and non-governmental organizations. Word clouds provide a simple and efficient means of visually transferring the most common words from text documents. This research aims to develop a word cloud model based on hateful words on online social media environment such as Google News. Several steps are involved including data acq

... Show More
View Publication Preview PDF
Scopus (9)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Tue Jan 30 2024
Journal Name
Iraqi Journal Of Science
Impact of Porous Media on Peristaltic Transport of Tangent Hyperbolic Nanofluid in Asymmetric Channel
...Show More Authors

The purpose behind this paper is to discuss nanoparticles effect, porous media, radiation and heat source/sink parameter on hyperbolic tangent nanofluid of peristaltic flow in a channel type that is asymmetric. Under a long wavelength and the approaches of low Reynolds number, the governing nanofluid equations are first formulated and then simplified. Associated nonlinear differential equations will be obtained after making these approximations. Then the concentration of nanoparticle exact solution, temperature distribution, stream function, and pressure gradient will be calculated. Eventually, the obtained results will be illustrated graphically via MATHEMATICA software.

View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Journal Of The College Of Languages (jcl)
Exploitation of the Democratization of Language in the Mass Media: Тенденция к демократизации языка в сми
...Show More Authors

      In the present paper, the features of democratization of vocabulary in the language of mass media are tackled. Particularly, the functions of this phenomenon in the context of language as an ontological reality are analysed. As well, the growing role  of the language of the media, and the language of politics as an integral part pertaining to it, is noted. Further, attention is paid to the excessive saturation of the language of the media along with the literary language, by means of evaluation which may include negative results.

     In this concern, scholars had different views, specifically in relation to the use of colloquial vocabulary along with some vernacular profess

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Jun 01 2010
Journal Name
Al-khwarizmi Engineering Journal
'Influence of Draft Tube Diameter on Operation Behavior of Air Lift Loop Reactors
...Show More Authors

The ratio of draft tube to reactor diameters is of decisive importance for the operation behavior of air lift loop reactors. The influence of draft tube geometry was investigated with respect to oxygen mass transfer and mixing time. The diameter ratio was varied between 0.33 and 0.80. The measurements were performed in two loop reactors with liquid capacities of 11.775 and 26.49 liters using aqueous with solutions of different coalescence behavior. The results show that there is no single diameter ratio which would produce most favorable conditions for the two process parameters. With respect to the more important requirements of aerobic cultures, i.e high oxygen mass transfer and efficient mixing, a diameter ratio between 0.5 and 0.6 is

... Show More
View Publication Preview PDF
Publication Date
Mon Jun 01 2015
Journal Name
Journal Of Engineering
Entransy dissipation of Shell and Double Concentric Tube Heat Exchanger Calculations and Analysis
...Show More Authors

Shell-and-double concentric tube heat exchanger is one of the new designs that enhance the heat transfer process. Entransy dissipation is a recent development that incorporates thermodynamics in the design and optimization of heat exchangers. In this paper the concept of entransy dissipation is related to the shell-and-double concentric tube heat exchanger for the first time, where the experiments were conducted using hot oil with temperature of 80, 100 and 120°C, flow rate of cold water was 0.667, 1, and 1.334 kg/m3 respectively and the temperature of inlet cold water was 20°C. The entransy dissipation rate due to heat transfer and to fluid friction or pressure drop was studied.

 

View Publication Preview PDF