Preferred Language
Articles
/
jkmc-155
A Comparison between High Ablative Versus Usual Dosages of Iodine-131 in Inducing Hypothyroidism After One Year of Therapy in Hyperthyroid Patients
...Show More Authors

Background: Radioactive iodine-131 therapy is highly effective in treating patients with hyperthyroidism. An ablative dose is preferred by a number of endocrinologists, and, a fixed dose protocol seems to be better than a calculated dose in real practice.

Objective: To check for hypothyroidism in hyperthyroid patients one year after RAI therapy, comparing between the results of high ablative versus usual dosages of RAI-131.

 Methods:  This study included 174 hyperthyroid patients, 101 males and 73 females, divided into 2 groups, the first consisted of 162 patients given a usual fixed dose of RAI while the second consisted of 12 patients given a high fixed ablative dose of RAI. The study lasted about 2 years from August 2000 till July 2002 in the Specialized Centre for Endocrinology & Diabetes, Baghdad.

Results: Out of 162 patients in the first group, 11 patients (6.8%), developed hypothyroidism compared to 4 patients out of 12 (33.3% )  in the second group ( p < 0.05).

 Conclusion: A high ablative dose RAI has a better outcome regarding hypothyroidism than a usual dose, although, endocrinologists have different opinions regarding this issue.

 

 

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Jan 01 2018
Journal Name
International Journal Of Science And Research
Comparison of Bacterial Contamination between I Phone and Galaxy Devices
...Show More Authors

Ninety eight mobile samples, (54) galaxy phone and (44) I phone, were swabbed for bacterial culture determination by culturing on MacConky agar , Blood agar , Mannitol salt agar , Muller Hinton agar .Staphylococcuswas the highest frequent isolated bacteria from Galaxy phone (33%) and I phone (37%). This study revealed that galaxy phone appears less contaminated with bacteria, the ratio of non-contaminated devices is (44%) when compared with I phone (9%). Sensitivity test showed that Ogmintin have the lowest effect on Staphylococcusisolated from both type of devices while cefitriaxone have the highest effect. DNA of isolate from galaxy 31 that exhibit highest resistance against antibiotics was extracted and 16S rRNA gene was polymerized by P

... Show More
Preview PDF
Publication Date
Mon Dec 01 2014
Journal Name
Journal Of Economics And Administrative Sciences
Comparison between some of linear classification models with practical application
...Show More Authors

Linear discriminant analysis and logistic regression are the most widely used in multivariate statistical methods for analysis of data with categorical outcome variables .Both of them are appropriate for the development of linear  classification models .linear discriminant analysis has been that the data of explanatory variables must be distributed multivariate normal distribution. While logistic regression no assumptions on the distribution of the explanatory data. Hence ,It is assumed that logistic regression is the more flexible and more robust method in case of violations of these assumptions.

In this paper we have been focus for the comparison between three forms for classification data belongs

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Jan 01 2026
Journal Name
Aip Conference Proceedings
Comparison between methods of solution kepler’s equation for elliptical orbit
...Show More Authors

Lagrange series and the Bessel function are two classical methods that were created by series expanding from Taylor series. In this paper, the purpose of those two methods was to find the values of the eccentric anomaly for one period (0–360)°. The Matlab program is used to apply the results, the input parameters were eccentricity (0–1), mean anomaly (0–360)°, and finally the parameter W (1–13). The program does not need a tolerance to obtain a precise value for eccentric anomaly like other iterative and non-iterative methods to stop the program; it will stop after completing the required period from 0° to 360° for a body that is determined by the solver. The output will be the final value of the eccentric anomaly. Furthermore,

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Sat Mar 31 2018
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
A Comparison between the Product-Refill and the Equalization Oxygen Pressure Swing Adsorption Processes
...Show More Authors

This work presents a design for a pressure swing adsorption process (PSA) to separate oxygen from air with approximately 95% purity, suitable for different numbers of columns and arrangements. The product refill PSA process was found to perform 33% better (weight of zeolite required or productivity) than the pressure equalization process. The design is based on the adsorption equilibrium of a binary mixture of O2 and N2 for two of the most commonly used adsorbents, 5A & 13X, and extension from a single column approach. Zeolite 13X was found to perform 6% better than zeolite 5A. The most effective variables were determined to be the adsorption step time and the operational pressure. Increasing the adsorption step

... Show More
View Publication Preview PDF
Publication Date
Sat Aug 21 2021
Journal Name
Engineering, Technology &amp; Applied Science Research
A Comparison between Static and Repeated Load Test to Predict Asphalt Concrete Rut Depth
...Show More Authors

Rutting has a significant impact on the pavements' performance. Rutting depth is often used as a parameter to assess the quality of pavements. The Asphalt Institute (AI) design method prescribes a maximum allowable rutting depth of 13mm, whereas the AASHTO design method stipulates a critical serviceability index of 2.5 which is equivalent to an average rutting depth of 15mm. In this research, static and repeated compression tests were performed to evaluate the permanent strain based on (1) the relationship between mix properties (asphalt content and type), and (2) testing temperature. The results indicated that the accumulated plastic strain was higher during the repeated load test than that during the static load tests. Notably, temperatur

... Show More
View Publication
Crossref (23)
Crossref
Publication Date
Thu Aug 27 2020
Journal Name
European Journal Of Ophthalmology
Comparison of corneal epithelial thickness profile in dry eye patients, keratoconus suspect, and healthy eyes
...Show More Authors
Purpose:

To compare the corneal epithelial thickness profile in patients with dry eyes and keratoconus suspect with normal healthy eyes.

Methods:

The study involved 120 eyes with an age range from 19 to 30 years. Forty eyes had normal corneal topography and no dry eyes. Forty eyes had dry eyes but had normal corneal topography. The last 40 eyes were keratoconus suspect and had no symptoms or signs of dry eyes.

Results:

Central epithelial thickness was not different statistically for all eyes. ( p-value: 0.1). The superior epithelial thickness was 53.5 µm ±3.1 in the control

... Show More
View Publication
Scopus (25)
Crossref (26)
Scopus Clarivate Crossref
Publication Date
Mon Dec 10 2018
Journal Name
Day 3 Wed, December 12, 2018
Experimental Comparison between WASP and LSASF in Bartlesville Sandstone Reservoir Cores Bearing Heavy Oil
...Show More Authors

Low salinity (LS) water flooding is a promising EOR method which has been examined by many experimental studies and field pilots for a variety of reservoirs and oils. This paper investigates applying LS flooding to a heavy oil. Increasing the LS water temperature improves heavy oil recovery by achieving higher sweep efficiency and improving oil mobility by lowering its viscosity. Steam flooding projects have reported many problems such as steam gravity override, but override can be lessened if the steam is is alternated with hot LS water. In this study, a series of reservoir sandstone cores were obtained from Bartlesville Sandstone (in Eastern Kansas) and aged with heavy crude oil (from the same reservoir) at 95°C for 45 days. Five reservo

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Wed Jan 01 2025
Journal Name
Eastern Ukrainian Medical Journal
IMPACT OF HIGHLY SELECTIVE VERSUS RELATIVELY SELECTIVE COX2 INHIBITORS ON INSULIN SENSITIVITY IN IRAQI PATIENTS DIAGNOSED WITH TYPE 2 DIABETES
...Show More Authors

Background: A worldwide health epidemic, type 2 diabetes mellitus was significantly influenced by chronic inflammation, which led to increased insulin resistance (IR). The most widely practiced form of therapy used to control musculoskeletal pain in people with diabetes is non-steroidal anti-inflammatory drugs (NSAIDs), which provide their action by inhibiting cyclooxygenase enzyme (COX). COX1, COX2, and COX3 are distinct isoforms of the cyclooxygenase enzyme. The potential anti-inflammatory benefits of cyclooxygenase-2 (COX-2) inhibitors, both selective and non-selective, have been investigated concerning the management of type 2 diabetes patients. Objective: the purpose of this research is to explore the impact of highly selective

... Show More
View Publication
Scopus Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Annals Of Tropical Medicine And Public Health
Role of high sensitivity C - Reactive protein and some of heavy metals in patients with rheumatoid arthritis
...Show More Authors

View Publication
Scopus (7)
Crossref (4)
Scopus Crossref
Publication Date
Fri Dec 15 2023
Journal Name
Iraqi Journal Of Laser
The Reliability of Two Different Laser Wavelengths in Inducing Bone Healing Around Dental Implants: Comparative Clinical Trial
...Show More Authors

Background/purpose: Dental implantology involves different treatments that have been used in conjunction with dental implant surgery to increase implant stability and bone regeneration process. Photobiomodulation( PBM) can be one of these techniques. The objective of this study was to evaluate the bone density around implants. Materials and methods: in this study, 10 individuals had 20 implants inserted in the posterior of their mandibles. each patient received two implants the left side served as the control whereas the right side served as the study group with a diode laser (same patients). measurements were made for each implant. Measurements were obtained using cone-

... Show More
View Publication Preview PDF
Crossref