Preferred Language
Articles
/
jkmc-139
Magnetic Resonance Venography Findings In A Group Of Patients With Multiple Sclerosis
...Show More Authors

Background: Multiple sclerosis is a chronic heterogeneous demyelinating axonal and inflammatory disease involving the Central Nervous System [CNS] white matter with a possibility of gray matter involvement in which the insulating covers of nerve cells in the brain and spinal cord are damaged. This damage disrupts the ability of parts of the nervous system to communicate, resulting in a wide range of signs and symptoms. Cerebral venous insufficiency theory was raised as a possible etiology for the disease at 2008 by Zamboni an Italian cardiothoracic surgeon. This theory was defeated by Multiple Sclerosis[ MS] researchers and scientists who thought that the disease is an autoimmune rather than vascular.

Objective: To assess the findings of Magnetic Resonance Venography [MRV] in a group of patients with MS and to compare these results with a healthy control group Magnetic Resonance Venography[ MRV] findings.

Type of the study: A case – control cross sectional study.

Methods: it was conducted at Neurosciences Hospital MS clinic from Oct.2014 to Dec. 2015, recruiting sequentially 50 patients who attend the MS clinic; 19 male and 31 females, their age was ranged from 16 to 53 year old. Diagnosis of MS was based on fulfillment of McDonald 2010 criteria for MS diagnosis, detailed history , examination and Expanded Disability Status Scale( EDSS)[see Appendix1] were recorded according to structured questionnaire forum. Each patient was send for Magnetic Resonance Venography[ MRV] using 3 Tessla Phillips model Achieva, 2012. The results of MRV were interpreted by specialist radiologist. Statistical analyses were done using SPSS version 21 with P value less than 0.05 was considered significant.

Results: Fifty patients with Multiple Sclerosis were involved in the study female 31, male 19, their ages were ranged between 21 and 60 year old. Magnetic Resonance Venography [MRV] findings suggest of venous thrombosis were seen in [4 / 50] 8% of patients and [46 /50] 92% of the patients in this study have no findings of venous thrombosis. The comparison with the control group showed no significant statistical difference.

Conclusion: Magnetic Resonance Venography[MRV] finding is not statistically different between healthy people and Multiple Sclerosis patient

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Nov 01 2018
Journal Name
Iraqi Journal Of Community Medicine
Leg alopecia in Patients with Coronary Heart Diseases in comparison with Healthy Control in Adult Males.
...Show More Authors

KE Sharquie, JR Al-Rawi, AA Noaimi, RA Al-Khammasi, Iraqi Journal of Community Medicine, 2018

View Publication
Publication Date
Thu Feb 18 2021
Journal Name
Journal Of Optical Communications
Theoretical investigation of multiple input–multiple output (MIMO) technique for line of sight (LoS) underwater wireless optical communications system
...Show More Authors
Abstract<p>In this paper, a theoretical investigation was suggested to study underwater wireless optical communication (UWOC) system based on multiple input–multiple output (MIMO) technique. The modulation schemes such as RZ-OOK, NRZ-OOK, 32-PPM and 4-QAM applied under different coastal water types. MIMO technique enabled the system to transmit data rate with longer distance link. The performance of the proposed system examined by BER and data rate as a metrics. Several impairments such as the types of water by the attenuation of coastal water and the distance link were taken into account for the transmission of the optical signal to appreciate the reliability of the MIMO technique. The theore</p> ... Show More
View Publication
Scopus (19)
Crossref (20)
Scopus Crossref
Publication Date
Fri Jan 01 2010
Journal Name
International Journal Of Communication Networks And Distributed Systems
A novel Radon-based multi-carrier direct sequence code division multiple access transceiver design and simulation
...Show More Authors

Multi-carrier direct sequence code division multiple access (MC-DS-CDMA) has emerged recently as a promising candidate for the next generation broadband mobile networks. Multipath fading channels have a severe effect on the performance of wireless communication systems even those systems that exhibit efficient bandwidth, like orthogonal frequency division multiplexing (OFDM) and MC-DS-CDMA; there is always a need for developments in the realisation of these systems as well as efficient channel estimation and equalisation methods to enable these systems to reach their maximum performance. A novel MC-DS-CDMA transceiver based on the Radon-based OFDM, which was recently proposed as a new technique in the realisation of OFDM systems, will be us

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Sat Aug 01 2020
Journal Name
Journal Of Engineering
Statistical Analysis of Metal Removal during Magnetic Abrasive Finishing Process
...Show More Authors

This work aims to provide a statistical analysis of metal removal during the Magnetic Abrasive Finishing process (MAF) and find out the mathematical model which describes the relationship between the process parameters and metal removal, also estimate the impact of the parameters on metal removal. In this study, the single point incremental forming was used to form the truncated cone made of low carbon steel (1008-AISI) based on the Z-level tool path. Then the finishing was accomplished using a magnetic abrasive process based on the Box-Behnken design of the experiment using Minitab 17 software was used to finish the surface of the formed truncated cone. The influences of different parameters (feed rate, machining step s

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Sat May 08 2021
Journal Name
Annals Of The Romanian Society For Cell Biology
Sequencing of IL-10 Gene Promoter for -592 (A/C) and -1082 (A/G) Positions in Iraqi Children Patients with Type 1 Diabetes Mellitus
...Show More Authors

We studied the relationship between DNA sequencing of interleukin-10 (IL-10) gene promoter for -1082 (A/G) and -592 (A/C) positions with the concentration of IL-10 in blood serum of Iraqi children with type 1 diabetes mellitus (T1D). Fifty blood serum samples collected from children with age ranged between 7-12 years. Thirty-five blood samples collected from patient children with T1D, and compared with 15 healthy children age matched as control sample. The results revealed decreasing in anti-inflammatory IL-10 concentration in T1D patient’s blood serum (0.068 Pg/ml) as compared with the control sample (0.111 Pg/ml). No significant differences were found in interleukin concentration between the studied samples when they analyzed with the M

... Show More
Preview PDF
Publication Date
Fri Nov 29 2019
Journal Name
Iraqi Journal Of Physics
Estimating sugar concentration in human blood serum using Surface Plasmon Resonance (SPR) –based optical fiber sensor
...Show More Authors

Surface Plasmon Resonance (SPR)-based plastic optical fiber sensor for estimating the concentration and refractive index of sugar in human blood serum. The sensor is fabricated by a small part (10mm) of optical fiber in the middle is embedded in a resin block and then the polishing process is done, after that it is deposited with about (40nm) thickness of gold metal. The blood serum is placed on gold coated core of an Optical grade plastic optical fiber of 980 µm core diameter.

View Publication Preview PDF
Crossref (7)
Crossref
Publication Date
Mon Dec 07 2020
Journal Name
Iranian Journal Of Parasitology
Serum levels of il-12 and il-23 in breast cancer patients infected with toxoplasma gondii: A case-control study
...Show More Authors

Scopus (2)
Scopus
Publication Date
Fri Jul 29 2022
Journal Name
Journal For Vascular Ultrasound
A Comparative Study of the Right and Left Carotid Arteries in Relation to Age for Patients With Diabetes and Hypertension
...Show More Authors
Introduction:

Age, hypertension, and diabetes can cause significant alterations in arterial structure and function, including changes in lumen diameter (LD), intimal-medial thickness (IMT), flow velocities, and arterial compliance. These are also considered risk markers of atherosclerosis and cerebrovascular disease. A difference between right and left carotid artery blood flow and IMT has been reported by some researchers, and a difference in the incidence of nonlacunar stroke has been reported between the right and left brain hemispheres. The aim of this study was to determine whether there are differences between the right and left common carotid arteries and internal carotid arteries in patient

... Show More
View Publication
Scopus (7)
Crossref (5)
Scopus Crossref
Publication Date
Wed Aug 31 2022
Journal Name
F1000research
Inflammatory markers in patients who presented with acute coronary syndrome and history of COVID-19 infection: a cross-sectional study
...Show More Authors

Background: During the COVID-19 outbreak, the number of patients who have developed acute coronary syndromes (ACS) has soared rapidly, cardiovascular disease and mortality are influenced by the elevated inflammatory biomarkers. The aim of this study is to compare inflammatory markers between patients with ACS who hadn’t previously had COVID-19 and those who’d be infected within the preceding three months; as well as, evaluating the effect of statins on inflammatory biomarkers.

Methods: This is a comparative cross-sectional study of 42 patients who presented with ACS and had previously had COVID-19 and 48 patient who had never had CO

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Oncology And Radiotherapy
Comparting study of cytokeratin 18 fragment M65 with CA19-9 and CEA as a biomarker in Iraqi colon cancer patients
...Show More Authors

Scopus