Preferred Language
Articles
/
jkmc-139
Magnetic Resonance Venography Findings In A Group Of Patients With Multiple Sclerosis
...Show More Authors

Background: Multiple sclerosis is a chronic heterogeneous demyelinating axonal and inflammatory disease involving the Central Nervous System [CNS] white matter with a possibility of gray matter involvement in which the insulating covers of nerve cells in the brain and spinal cord are damaged. This damage disrupts the ability of parts of the nervous system to communicate, resulting in a wide range of signs and symptoms. Cerebral venous insufficiency theory was raised as a possible etiology for the disease at 2008 by Zamboni an Italian cardiothoracic surgeon. This theory was defeated by Multiple Sclerosis[ MS] researchers and scientists who thought that the disease is an autoimmune rather than vascular.

Objective: To assess the findings of Magnetic Resonance Venography [MRV] in a group of patients with MS and to compare these results with a healthy control group Magnetic Resonance Venography[ MRV] findings.

Type of the study: A case – control cross sectional study.

Methods: it was conducted at Neurosciences Hospital MS clinic from Oct.2014 to Dec. 2015, recruiting sequentially 50 patients who attend the MS clinic; 19 male and 31 females, their age was ranged from 16 to 53 year old. Diagnosis of MS was based on fulfillment of McDonald 2010 criteria for MS diagnosis, detailed history , examination and Expanded Disability Status Scale( EDSS)[see Appendix1] were recorded according to structured questionnaire forum. Each patient was send for Magnetic Resonance Venography[ MRV] using 3 Tessla Phillips model Achieva, 2012. The results of MRV were interpreted by specialist radiologist. Statistical analyses were done using SPSS version 21 with P value less than 0.05 was considered significant.

Results: Fifty patients with Multiple Sclerosis were involved in the study female 31, male 19, their ages were ranged between 21 and 60 year old. Magnetic Resonance Venography [MRV] findings suggest of venous thrombosis were seen in [4 / 50] 8% of patients and [46 /50] 92% of the patients in this study have no findings of venous thrombosis. The comparison with the control group showed no significant statistical difference.

Conclusion: Magnetic Resonance Venography[MRV] finding is not statistically different between healthy people and Multiple Sclerosis patient

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Nov 01 2018
Journal Name
Journal Of Economics And Administrative Sciences
Comparison of Estimates Nonparametric In Multiple Regression Analysis Function (Gamma ,Beta)
...Show More Authors

The use of non-parametric models and subsequent estimation methods requires that many of the initial conditions that must be met to represent those models of society under study are appropriate, prompting researchers to look for more flexible models, which are represented by non-parametric models                  

          In this study, the most important and most widespread estimations of the estimation of the nonlinear regression function were investigated using Nadaraya-Watson and Regression Local Ploynomial, which are one of the types of non-linear

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Apr 01 2021
Journal Name
Computer Methods And Programs In Biomedicine
A hybrid approach based on multiple Eigenvalues selection (MES) for the automated grading of a brain tumor using MRI
...Show More Authors

View Publication
Scopus (43)
Crossref (39)
Scopus Clarivate Crossref
Publication Date
Wed Dec 01 2010
Journal Name
Iraqi Journal Of Physics
Elastic magnetic electron scattering form factor in Ca-41 (M3Y fitting parameters consideration)
...Show More Authors

Elastic magnetic electron scattering form factors in Ca-41 have been investigated. 1f7/2 subshell has been adopted as a model space with one neutron, and Millinar, Baymann and Zamick 1f7/2 model space effective interaction (F7MBZ) has been used as a model space effective interaction to generate the model space vectors for the M1, M3, M5, M7, and total form factors. Discarded space (core and higher configuration orbits) have been included through the first order perturbation theory to couple the partice-hole pair of excitation with 2ћω excitation energy in the calculation of the form factors and regarding the realistic interaction density dependence M3Y as a core polarization interaction with five sets of modern fitting parameters. Fina

... Show More
View Publication Preview PDF
Publication Date
Sun Jan 13 2019
Journal Name
Iraqi Journal Of Physics
Inelastic transverse magnetic dipole electron scattering form factors in 48Ca (restricted optimum configurations)
...Show More Authors

Inelastic transverse magnetic dipole electron scattering form
factors in 48Ca have been investigated through nuclear shell model
in an excited state energy Ex= 10.23 MeV which is so called
"mystery case" with different optional choices like effective
interaction, restricted occupation and core polarization interaction.
40Ca as an inert core will be adopted and four orbits with eight
particles distributed mainly in 2p1f model space and in some extend
restricted to make sure about the major accuse about this type of
transition. Theoretical results have been constituted mainly with
experimental data and compared with some important theoretical
results of the same transition.

View Publication Preview PDF
Crossref
Publication Date
Thu Dec 01 2022
Journal Name
Int. J. Agricult. Stat. Sci.
STRAWBERRY CV. FESTIVAL GROWTH IN RESPONSES TO MAGNETIC WATER AND FOLIAR APPLICATION OF COCONUT EXTRACT
...Show More Authors

This study was carried out to study effect of magnetic water ( M0 and M) and different concentrations of coconut extract in Fragaria x ananassa (Duch) C.V Festival. The results showed significant differences in the plants treated with magnetic water ( 0.12 Tesla) and different concentrations of coconut extract C1 (0%), C2 (2.5%), C3 (5%), C4 (7.5%) and C5 (10%) in vegetative parameters as in leaf area and chlorophyll in treatment M0C3 was (53.72 Dcm2, 50.00), respectively, highest leaf number and plant dry weight in MC4 (12.77,14.22 gm), respectively. Results recorded significant differences in fruit parameters such as weight in MC1 (18.97 gm). The maximum fruit number was in MC3 (110), the greatest fruit size was in MC4 (15.78 cm3) and the

... Show More
View Publication
Scopus
Publication Date
Sun Nov 01 2020
Journal Name
Journal Of Engineering
Preparation and Characterization of Plaster Kiln Dust-Fe3O4 Magnetic Nanoparticles
...Show More Authors

Magnetic plaster kiln dust (MPKD) was synthesized as a unique, low-cost composite reused of byproduct plaster kiln dust (PKD), which is considered a source of air pollution. The FESEM, EDS, XRD, FTIR, VSM, and BET tests were used to characterize the MPKD. The characterization revealed that the MPKD was nanotubes non-agglomerated and super-paramagnetic with a high specific surface area (102.7 m2/g). Compared with the specific area of other materials (composites), the MPKD could be considered a promising substance in the field of water/wastewater treatment.

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Jan 31 2024
Journal Name
Journal Of The Faculty Of Medicine Baghdad (jfacmed Baghdad)
The Role of Activin A levels, Body Mass Index and Beta-Human Chorionic Gonadotropin in Ectopic Pregnancies and Missed Abortions – A Study on a Group of Iraqi Women
...Show More Authors

Publication Date
Sun Jul 12 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Estimation of the linear dimensional changes of autoclave cured acrylic resin with multiple palatal depths and investment materials
...Show More Authors

Background: Dimensional changes of acrylic denture bases after polymerization results in need for further adjustments or even ends with technical failure of the finished dentures. The purpose of this study was to estimate the linear dimensional changes for different palatal depths when using multiple investment materials and polymerization techniques. Materials and methods: Ninety upper complete denture bases were constructed for this study. They were divided into two main groups according to the polymerization methods: conventional water bath and experimental autoclave (short and long cycles). Each main group was further subdivided into three subgroups according to the palatal depth (shallow, medium and deep). Furthermore, for each palatal

... Show More
View Publication Preview PDF
Publication Date
Mon Feb 23 2026
Journal Name
Baghdad Science Journal
Determination of Mebeverine – HCl Using 3, 5–Dinitrosalicylic Acid and Multiple Continuous Flow Cell That Works as a Solo Flow Cell with 4S×3 – 3D Analyzer
...Show More Authors

A new method, simple and sensitive was utilized in determining mebeverine – HCl (MB-HCl) (3, 4-Dimethoxy benzoic acid ethyl 2, 4 methoxy4-phenyl-1-methyl ethyl amino-butyl ester) in pure and pharmaceutical formulations via utilization this multiple continuous flow cell. The method is dependent on genesis for complex of ion pair(4-((3, 4-dimethoxybenzoyl) oxy)-N-ethyl-N-(1-(4-methoxyphenyl) propan-2-yl) butan-1-aminium-2-hydroxy-3,5- dinitrobenzoate) among mebeverine–HCl (MB-HCl) and 3,5-Dinitrosalicylic acid (3,5-DNSA) in ammonium acetate middle to configure a whiteish yellow precipitate compound via utilizing multiple continuous flow cell that works as a solo flow cell with 4S×3 – 3D analyzer. Optimum parameters were studied to rai

... Show More
View Publication
Publication Date
Sun Jun 03 2012
Journal Name
Baghdad Science Journal
A Biochemical Study for Evaluation and Analysis of Serum Protein of Patients with Different Kidney Tumors
...Show More Authors

The amount of protein in the serum depends on the balance between the rate of its synthesis, and that of its catabolism or loss. Abnormal metabolism may result from nutritional deficiency, enzyme deficiency, abnormal secretion of hormones, or the actions of drugs and toxins. Renal cancer is the third most common malignancy of the genitourinary system, and accounts for 3% of adult malignancies globally. Total serum proteins were measured in malignant kidney tumor, benign kidney tumors, and non tumoral kidney diseases patient groups, as well as in healthy individuals. A significant decrease (p< 0.001) of total serum protein levels in patients with malignant kidney tumors when compared with those of benign tumors, non tumoral diseases, and hea

... Show More
View Publication Preview PDF
Crossref