Preferred Language
Articles
/
jkmc-1218
Radiological Significance of Shear-Wave Elastography Technique for Evaluation of Solid Breast Masses with Histopathological Correlation
...Show More Authors

Background: Although various imaging modalities are available for evaluating suspicious breast lesions, ultrasound-based Shear-Wave Elastography (SWE) is an advanced, non-invasive technique complementary to grayscale sonography. This technique evaluates the elasticity of a specific tissue by applying sonic pressure to that tissue.

Objective: The aim is to assess the role of SWE in evaluating solid breast masses in correlation to histopathological study results.

Subjects and Methods: This prospective study was done in a tertiary care teaching hospital from September 2019 to August 2020. A study population of 50 women aged 18 years or above with an ultrasonographic (USG) diagnosis of solid breast masses was included.

Results: A significantly higher value of SWE elasticity ratio (E-mean) was observed in malignant tumors than in benign tumors (p <0.0001).  The area-under-curve (AUC) for the BI-RADS 4 lesions was 0.522 (95% CI, 0.343-0.701) with an E-ratio cut-off score of 85.25, the sensitivity and specificity were 50% for diagnosing malignant tumors, whereas AUC for the HPE study was 1.000 (95% CI, 1.000-1.000) with an E-ratio cut-off score of 134.25; both the sensitivity and specificity were 100% for diagnosing malignant tumors.

Conclusions: Carcinoma breast is one of the most prevalent cancers globally. The most common benign tumor of the breast is a fibroadenoma, whereas Invasive Ductal Carcinoma is the most common malignant breast mass. A well-defined SWE elasticity ratio range might help predict the aggressiveness of breast tumors. SWE's correlation with BI-RADS in suspicious lesions adds to histopathology's advantage in distinguishing malignant tumors from benign ones.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Mar 01 2014
Journal Name
Food Chemistry
Micro-solid phase extraction with liquid chromatography–tandem mass spectrometry for the determination of aflatoxins in coffee and malt beverage
...Show More Authors

A single step extraction-cleanup procedure using porous membrane-protected micro-solid phase extraction (μ-SPE) in conjunction with liquid chromatography–tandem mass spectrometry for the extraction and determination of aflatoxins (AFs) B1, B2, G1 and G2 from food was successfully developed. After the extraction, AFs were desorbed from the μ-SPE device by ultrasonication using acetonitrile. The optimum extraction conditions were: sorbent material, C8; sorbent mass, 20 mg; extraction time, 90 min; stirring speed, 1000 rpm; sample volume, 10 mL; desorption solvent, acetonitrile; solvent volume, 350 μL and ultrasonication period, 25 min without salt addition. Under the optimum conditions, enrichment factor of 11, 9, 9 and 10 for AFG2, AFG1

... Show More
View Publication
Scopus (63)
Crossref (62)
Scopus Clarivate Crossref
Publication Date
Mon Aug 30 2021
Journal Name
Russian Electronic Journal Of Radiology
THE ROLE OF APPARENT DIFFUSION COEFFICIENT VALUE IN DIFFERENTIATING BENIGN FROM MALIGNANT SOFT TISSUE MASSES
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Wed Aug 31 2022
Journal Name
Al-kindy College Medical Journal
Automated breast ultrasound: A comparison study with handheld ultrasound in detection and characterization of lesions in mammographically dense breast
...Show More Authors

Background: Although mammography is a powerful screening tool in detection of early breast cancer, it is imperfect, particularly for women with dense breast, which have a higher risk to develop cancer and decrease the sensitivity of mammogram, Automated breast ultrasound is a recently introduced ultrasonography technique, developed with the purpose to standardize breast ultrasonography and overcome some limitations of handheld ultrasound, this study aims to evaluate the diagnostic efficacy of Automated breast ultrasound and compare it with handheld ultrasound in the detection and characterization of breast lesions in women with dense breasts. Objectives: To evaluate the diagnostic efficacy of Automated breast ultrasound and compare

... Show More
Crossref
Publication Date
Sun Dec 27 2020
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Assessment of Some Hematological parameters in Iraqi Women with Different Breast Cancer Stages
...Show More Authors

Breast cancer (BC) is the most commonly diagnosed cancer in women. The metabolism of iron is closely regulated by hepcidin which exerts its action by interacting with a ferroportin.

 The aim of the present study was to assess the alterations in the levels of some serum biomarkers that have a role in iron homeostasis (hepcidin and ferroportin) in addition to hematological parameters (hemoglobin, leukocyte and platelets count) in different stages of BC.

This study included 66 women with BC. The patients were categorized as follows : group 1 includes :22 patients with stage I disease ,group 2 includes: 22 patients with stage II disease ,and group 3 include: 22 patients with stage III disease .Group 4 includes :22 appare

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (2)
Scopus Crossref
Publication Date
Fri Apr 01 2016
Journal Name
Journal Of Engineering
Experimental Behavior of Steel-Concrete-Steel Sandwich Beams with Truss Configuration of Shear Connectors
...Show More Authors

This paper presents experimentally a new configuration of shear connector for Steel-Concrete-Steel (SCS) sandwich beams that is derived from truss configuration. It consists of vertical and inclined shear connectors welded together and to cover steel plates infilled with concrete. Nine simply supported SCS beams were tested until the failure under a concentrated central load (three- point bending). The beams were similar in length (1100mm), width (100mm), and the top plate thickness (4mm). The test parameters were; beam thickness (150, 200, 250, and 300mm), the bottom plate thickness (4, and 6mm), the diameter of the shear connectors (10, 12, and 16mm), and the connector spacing (100, 200, and 250mm). The test results sh

... Show More
View Publication Preview PDF
Publication Date
Sat Feb 02 2019
Journal Name
Journal Of The College Of Education For Women
Defining the Feature of Cold Wave (Al-Marba'aniyah) in Iraq: Defining the Feature of Cold Wave (Al-Marba'aniyah) in Iraq
...Show More Authors

Abstract:
Al-Marba'aniyah, which is a long cold wave, was defined by ancient
Iraqis. It represents the coldest days in Iraq. In this research paper, a new
scale was put to define it. It shows that the period between the minimum
temperature degree recoded in December and the minimum temperature
degree recorded in January is considered to be the period of Al-Marba'aniyah.
The research concluded that Al-Marba'aniyah is unsteady and it changes in
the days of its occurrence. It was also concluded that the dates of the
beginning and the end of Al-Marba'aniyah are unsteady, too. Moreover, it was
found out that each of the Siberian high, European high, and finally the
subtropical high are the responsible systems for

... Show More
View Publication Preview PDF
Publication Date
Sun Feb 03 2019
Journal Name
Journal Of The College Of Education For Women
Body parts idioms; across-cultural significance
...Show More Authors

0

View Publication Preview PDF
Publication Date
Sat Oct 01 2022
Journal Name
The Egyptian Journal Of Hospital Medicine
The Effects of Soft Laser on Some Blood Parameters of Patients with Breast Cancer
...Show More Authors

Background: Soft Laser has been advantageous in medical applications and is widely used in clinical practice. It is applied because it doesn’t cause the significant thermal effects or tissue hurt when irradiated. The blood response to low power laser radiation provides information about processes of laser radiation interaction with live creatures. Objective: The aim of the current work was to evaluate the laser-induced changes of in vitro erythrocyte sedimentation rate (ESR), mean corpuscular volume (MCV), and mean corpuscular hemoglobin concentration (MCHC) in patients with breast cancer by irradiating a human blood sample using a green laser and comparing its effects before and after irradiation with the same power density (100mW/c

... Show More
Publication Date
Thu Aug 31 2023
Journal Name
Oncology And Radiotherapy
The role of breath holding technique on minimizing cardiac dose in left breast cancer irradiation in the adjuvant setting
...Show More Authors

Scopus
Publication Date
Thu Oct 01 2020
Journal Name
Journal Of Engineering
A Study of Fluctuation and Expansion Ratios for Gas-Solid Fluidized Columns
...Show More Authors

The fluctuation and expansion ratios have been studied for cylindrical gas-solid fluidized columns by using air as fluidizing medium and Paracetamol as the bed material. The variables were the column diameter (0.0762, 0.15, and 0.18 m), static bed height (0.05, 0.07, and 0.09 m), and air velocity to several times of minimum fluidization velocity. The results showed that both the fluctuation and expansion ratios had a direct relation with air velocity and an inverse one with column diameter and static bed height. A good agreement was between the experimental results and the calculated values by using the correlation equations from the literature.

View Publication Preview PDF
Crossref