Environmental Control Systems form one of the integral tasks of the designer, resulting from his/her acquaintance with the nature of sites and the way they are deployed to achieve modern space entity which is witnessing significant development in the field of interior design.Good deployment of these systems offer us, as designers, high potential and several varied solutions to configure internal spaces characterised as a fertile field of study and knowledge.The research problem was identified in the marginalisation of the importance of Environmental Control Systems as an important designing factor to achieve integrated design. The research problem was demonstrated in Chapter One, along with defining the objectives and formulating the research hypotheses.Chapter Two contained the research theoretical framework, which consists of a review of overall design trends and options when addressing Environmental Control Systems, by studying the most important influential factors of these systems, followed by key indicators derived from the theoretical framework which were, then, utilised in subsequent research procedures. In Chapter Three comes the stage of identifying the research methodology, the research community and the research sample, represented by two samples, and collecting information about them. The research tool was developed through what is construed from the theoretical framework.Chapter Four represented analysis of the content of selected research sample and results of the research were demonstrated, and, in light of these results, the research came out with findings which identified and explained the main differences resulting from deploying the best processors for Heating and Cooling Systems and, therefore, the most important design proposals and recommendations were identified to reach approved design decisions and utilising them to acquire a design product which achieves its objective
Abnormalities in the Lipid and lipoprotein levels are common in the general population and are considered as very important risk- factors for cardiovascular disease .In this context the effect of cholesterol, which is one of the most clinically relevant lipids is very important. Aim of the present study was to determine the levels of GLP-1 and GPCR in non- diabetic dyslipidaemic patients and compare the results with the control group, which may be used as a novel biomarker to predict heart disease in these patients. The study was also aimed to find the relationship between GLP-1 and GPCR with lipid profile and glucagon in the patient group. The study involved 90 non-diabetic dyslipidaemia patients, with 90 healthy controls. The subjects wer
... Show MoreA total of 54 out of 67 (80.59%) of burn wound swab showed growth of one, or two, or three bacterial pathogens. Pseudomonas aeruginosa was the commonest pathogen, isolated in 48.14% of swab samples, followed by Klebsiella pneumoniae (31.48%), Staphylococcus aureus (27.77%), Acinetobacter baumanii (14.81%), Escherichia coli (7.40%), and Citrobacter freundii, Providencia stuartii, Enterobacter cloacae, with 1.85% isolation percentage for each. All bacterial isolates were tested against 19 antibiotics, and showed multi-drug resistance to 10 antibiotics, or more. The most effective antibiotics were the fifth-generation cephalosporin, ceftobiprole, and and antibiotic combinations, as Ceftazidime / clavulanic acid, and Cefoperazone /sulbactam, an
... Show MoreCentral banks around the world typically use various financial indicators to evaluate performance. In Iraq, the indicators used by central banks to evaluate the performance of banks are of great importance to ensure that the banks operating within the Iraqi banking system comply with the regulatory and legal requirements issued by the Central Bank of Iraq or the Ministry of Finance. Given the need to study the profitability indicator to ensure its ability to evaluate the performance of specialized banks in Iraq, these banks carry out their banking activities and businesses through capital funded by the government. The use of profitability indicators in evaluating the performance of specialized banks provides information about the profitabil
... Show MoreThis study was conducted to describe a protocol for the callus establishing culture of Lavandula angustifolia plant and estimating their content of volatile oil. The quantity of volatile oil callus tissues was compared with that of leaves production. Callus was induced from leaf explants on Murashige and Skoog medium (MS) supplemented with Naphthalene acetic acid (NAA) and Benzyl adenine (BA) in different concentrations. Maximum callus fresh weight was obtained in the combination of 10 mg/L BA and 3 mg/L NAA which reached 18 g after four weeks. The results of this work showed that the quantity of volatile oil from the highest fresh weight callus was 6 ml compared with quantity of 18g of leaves which gave 0.5 ml. Volatile o
... Show MoreCervical cancer is the third most common cancer in women worldwide, and it has the fourth highest mortality rate among cancers in women. The present study aimed to reveal the impact of age factor in cervical abnormalities and cancers incidence in some Iraqi married women. 150 scraping cervical cells samples were collected from the women clinically diagnosed with cervical abnormalities and cancer who were divided into two groups; the first group included the women with abnormal pap smear which revealed 13.33% of women were less than 30 years and followed by 66.66% of women whose age between 30-50 years and 20% of them were more than 50 years old. While the second group iclude the women with normal Pap smear (Healthy women) which revealed tha
... Show MoreThe current study presents an experimental investigation of heat transfer and flow characteristic for subcooled flow boiling of deionized water in the microchannel heat sink. The test section consisted of a single microchannel having 300μm wide nominal dimensions and 300μm height (hydraulic diameter of 300μm). The test section formed of oxygen-free copper with 72mm length and 12mm width. Experimental operation conditions spanned the heat flux (78-800) kW/m2, mass flux (1700 and 2100) kg/m2.s at 31˚C subcooled inlet temperature. The boiling heat transfer coefficient is measured and compared with existing correlations. Also, the experimental pressure drop is measured and compared with microscale p
... Show More