The contemporary arts, including the graphic design art, adopted new concepts and methods that diverged from the customary rules of design, such as the method of irregularity, as a result of the art keeping up with the intellectual, scientific and technical developments that accompanied all fields of life which caused a problem in employing this technique because of its influence on the functional aspect of the graphic achievement. Hence, the researcher chose the title of the research entitled (the irregularity in contemporary graphic achievement) based on the following questions: a-Does the transformation of style in contemporary graphic design constitute a problem for the designs it produces?b- Has the contemporary graphic design achieved its aesthetic dimensions through the irregularity method? The theoretical framework included four sections as follows: The first section is the irregularity in the philosophy of art, and the second section is the irregularity in design and the third one is the irregularity through the elements of design and the fourth section included the techniques of the artistic direction of the graphic achievement, then the research procedures included the analysis of the research sample. The most important findings and conclusions were as follows:A - The method of irregularity is one of the contemporary technical methods that have made a big-time change in the construction of contemporary graphic design and added an aesthetic and functional dimension to the modern design system.B - The method of the irregularity adopted the mechanism of innovation in dealing with the design elements being influential design forces capable of violating the design system, as well as technological developments that contributed to the formulation of these elements and influence them in an unusual way.
The UV−VIS absorption spectroscopy technique was used to study the formation of a new complex of charge transfer (CT) between bioactive organic molecules as (Nystatin) containing both a π-electrons from a conjugated system and lone-pair of electrons (amine) with Tetrachloro-1,4 benzoquinone (TCBQ) as a π-acceptor in which the transferred electron goes into its vacant anti-bonding molecular orbitals. The Tyrian purple-colored complex formed was quantitatively measured at 544 nm. This complex shows obeying Beer's law within the concentration range of (10-90) μg.ml-1The stoichiometry of the formed complex between the (Nys.) and (TCBQ) was found 1:2 as evaluated by continuous variation (Job's method) and mole ratio method The value of mola
... Show MoreThe objective of study was determining the most prevalent Salmonella spp. and their antimicrobial susceptibility in broilers and laying chickens and their feed and drinking water in five chicken farms in Karbala, Iraq over the period from August to October 2020. A total of 289 samples, including 217 cloaca swabs, 46 water and 26 feed samples were collected. Salmonella spp. was identified firstly by routine diagnostic methods, followed by applying the API 20E kit, the Vitek2 system, and serology. There was significant differences in Salmonella prevalence among different types of samples, mainly cloaca swabs reported a high isolation rate (21.7%). In contrast, feed samples were completely free of contamination. The highest rate of isolation w
... Show MoreDBN Rashid, JOURNAL OF XI'AN UNIVERSITY OF ARCHITECTURE & TECHNOLOGY, 2020
New simple and sensitive spectrophotometric methods for the determination of paracetamol in aqueous medium were developed. The first method is based on coupling of paracetamol with p-amino-2-hydroxy sodium benzoate (AHB) in the presence of sodium periodate, as oxidizing agent, to form a brownish-orange compound which shows a λmax at 470 nm. The molar absorptivity (εmax) of the colored product was found to be (3371) l. mole1. cm-1 and Sandel’s index 0.0449 μg. cm-2. The method follows Beer’s law in the concentration range of 12.5-500.0 μg of paracetamol in a final volume of 25 ml (0.5-20.0) μg. ml-1 with relative standard deviation percent (RSD%) ranged between 0.26-4.71% and accuracy, expressed by recovery percent, 95-106% for five
... Show More