The current research deals with the argument of delusion and interpretation in the direction structure and its reflected impact in the reception activity and the amount of conceptual displacement it is subjected to in an aesthetic approach to abstract conceptual definitions of the reception activity , by the effect of this dialectic in the direction structure, which can be summed up by the following question: (What are the characteristics of the direction structure of the imaginary and what is the argument of interpretation in the theatre reception activity?) in order to stand on the aesthetic framework and conceptual definition of the direction structure in the controversy of interpretation and imagination, and its impact on the conceptual and procedural definition of the theatre reception activity, through monitoring the repercussions of this controversy of the direction structure in the theatre reception activity , which limited the research with a pivotal aim: (Showing the activity of the imagination and interpretation controversy and the direction structure of the visualizer, and monitoring its aesthetic impact on the theatre reception concept). The research comes up within the limits set forth in its methodological framework, to analyze the studied phenomenon in order to identify it, conceptualize it, and employ it procedurally. The research consists of three frameworks:
The methodological framework in which the researcher identified the problem of the research, its importance, the need for it, its purpose, and its limits, as well as defining its terms procedurally.
The theoretical framework is of two axes: the first is the axis of the argument of delusion and interpretation in the direction structure, and the second axis is the controversy of delusion and interpretation in the theatre reception.
The procedural framework included the researcher's procedures in applying the theoretical framework indicators to his chosen sample, namely the play "Mukashafat" (confessions) to monitor the conceptual effect of the controversy of interpretation and delusion in the direction structure, on the theatre reception concept. The research came up with a number of conclusions, the most important of which are: the theatre reception is a controversial act, in which the debate moved towards the activity of delusion and its criterion is the achievement of the assumption, and the activity of interpretation and its criterion is the achievement of the discovery.
This article presents the results of an experimental investigation of using carbon fiber–reinforced polymer sheets to enhance the behavior of reinforced concrete deep beams with large web openings in shear spans. A set of 18 specimens were fabricated and tested up to a failure to evaluate the structural performance in terms of cracking, deformation, and load-carrying capacity. All tested specimens were with 1500-mm length, 500-mm cross-sectional deep, and 150-mm wide. Parameters that studied were opening size, opening location, and the strengthening factor. Two deep beams were implemented as control specimens without opening and without strengthening. Eight deep beams were fabricated with openings but without strengthening, while
... Show MoreThis study included the isolation and identification of Aspergillus flavus isolates associated with imported American rice grains and local corn grains which collected from local markets, using UV light with 365 nm wave length and different media (PDA, YEA, COA, and CDA ). One hundred and seven fungal isolates were identified in rice and 147 isolates in corn.4 genera and 7 species were associated with grains, the genera were Aspergillus ,Fusarium ,Neurospora ,Penicillium . Aspergillus was dominant with occurrence of 0.47% and frequency of 11.75% in rice grains whereas in corn grains the genus Neurospora was dominant with occurrence of 1.09% and frequency 27.25% ,results revealed that 20 isolates out of 50 A. flavus isolates were able
... Show MoreProtection of the oil pipelineswhich extracted from the wells was found to shut the well and prevent the leakage of oil when broken using safety valve. This valve is automatically activated by loss of pressure between the well and pipelines, which take the pressure, signal from hydraulic pressure sensor through pressure control valve which has constant or variable value but it is regulated manually. The manual regulatory process requires the presence of monitoring workers continuously near the wells which are always found in remote areas. In this paper, a smart system has been proposed that work with proportional pressure control valve and also electronic pressure sensor through Arduino controller, which is programmed in a way that satisfie
... Show MoreNew Fe(II),Co(II),Ni(II),Cu(II) and Zn(II) Schiff base complexes which have the molar ratio 2:1 metal to ligand of the general formula [M2( L) X4] (where L=bis(2-methyl furfuraldene)-4-4`-methylene bis(cyclo-hexylamine) ) were prepared by the reaction of the metal salts with the ligand of Schiff base derived from the condensation of 2:1 molar ratio of 2-acetyl furan and 4-4`-methylene bis (cyclohexylamine). The complexes were characterized by elemental analysis using atomic absorption spectrophotometer ,molar conductance measurements, infrared, electronic spectra,and magnetic susceptibility measurement. These studies revealed binuclear omplexes. The metal(II) ion in these complexes have four coordination sites giving the most ex
... Show MoreFiber Reinforced Polymer (FRP) bars are anisotropic in nature and have high tensile strength in the fiber direction. The use of High-Strength Concrete (HSC) allows for better use of the high-strength properties of FRP bars. The mechanical properties of FRP bars can yield to large crack widths and deflections. As a result, the design of concrete elements reinforced with FRP materials is often governed by the Serviceability Limit States (SLS). This study investigates the short-term serviceability behavior of FRP RC I-beams. Eight RC I-beams reinforced with carbon-FRP (CFRP) and four steel RC I-beams, for comparison purposes, were tested under two-point loading.
Deformations on the concrete and crack widths and spacing are measured and
In this study, a three-dimensional finite element analysis using ANSYS 12.1 program had been employed to simulate simply supported reinforced concrete (RC) T-beams with multiple web circular openings subjected to an impact loading. Three design parameters were considered, including size, location and number of the web openings. Twelve models of simply supported RC T-beams were subjected to one point of transient (impact) loading at mid span. Beams were simulated and analysis results were obtained in terms of mid span deflection-time histories and compared with the results of the solid reference one. The maximum mid span deflection is an important index for evaluating damage levels of the RC beams subjected to impact loading. Three experi
... Show More