The current research deals with the argument of delusion and interpretation in the direction structure and its reflected impact in the reception activity and the amount of conceptual displacement it is subjected to in an aesthetic approach to abstract conceptual definitions of the reception activity , by the effect of this dialectic in the direction structure, which can be summed up by the following question: (What are the characteristics of the direction structure of the imaginary and what is the argument of interpretation in the theatre reception activity?) in order to stand on the aesthetic framework and conceptual definition of the direction structure in the controversy of interpretation and imagination, and its impact on the conceptual and procedural definition of the theatre reception activity, through monitoring the repercussions of this controversy of the direction structure in the theatre reception activity , which limited the research with a pivotal aim: (Showing the activity of the imagination and interpretation controversy and the direction structure of the visualizer, and monitoring its aesthetic impact on the theatre reception concept). The research comes up within the limits set forth in its methodological framework, to analyze the studied phenomenon in order to identify it, conceptualize it, and employ it procedurally. The research consists of three frameworks:
The methodological framework in which the researcher identified the problem of the research, its importance, the need for it, its purpose, and its limits, as well as defining its terms procedurally.
The theoretical framework is of two axes: the first is the axis of the argument of delusion and interpretation in the direction structure, and the second axis is the controversy of delusion and interpretation in the theatre reception.
The procedural framework included the researcher's procedures in applying the theoretical framework indicators to his chosen sample, namely the play "Mukashafat" (confessions) to monitor the conceptual effect of the controversy of interpretation and delusion in the direction structure, on the theatre reception concept. The research came up with a number of conclusions, the most important of which are: the theatre reception is a controversial act, in which the debate moved towards the activity of delusion and its criterion is the achievement of the assumption, and the activity of interpretation and its criterion is the achievement of the discovery.
A novel demountable shear connector for precast steel-concrete composite bridges is presented. The connector uses high-strength steel bolts, which are fastened to the top flange of the steel beam with the aid of a special locking nut configuration that prevents bolts from slipping within their holes. Moreover, the connector promotes accelerated construction and overcomes the typical construction tolerance issues of precast structures. Most importantly, the connector allows bridge disassembly. Therefore, it can address different bridge deterioration scenarios with minimum disturbance to traffic flow including the following: (1) precast deck panels can be rapidly uplifted and replaced; (2) connectors can be rapidly removed and replaced; and (
... Show MoreThe objective of the current research is to find an optimum design of hybrid laminated moderate thick composite plates with static constraint. The stacking sequence and ply angle is required for optimization to achieve minimum deflection for hybrid laminated composite plates consist of glass and carbon long fibers reinforcements that impeded in epoxy matrix with known plates dimension and loading. The analysis of plate is by adopting the first-order shear deformation theory and using Navier's solution with Genetic Algorithm to approach the current objective. A program written with MATLAB to find best stacking sequence and ply angles that give minimum deflection, and the results comparing with ANSYS.
The dynamic development of computer and software technology in recent years was accompanied by the expansion and widespread implementation of artificial intelligence (AI) based methods in many aspects of human life. A prominent field where rapid progress was observed are high‐throughput methods in biology that generate big amounts of data that need to be processed and analyzed. Therefore, AI methods are more and more applied in the biomedical field, among others for RNA‐protein binding sites prediction, DNA sequence function prediction, protein‐protein interaction prediction, or biomedical image classification. Stem cells are widely used in biomedical research, e.g., leukemia or other disease studies. Our proposed approach of
... Show MoreAbstract: A novel design of Mach Zehnder Interferometer (MZI) in terms of using special type of optical fiber that has double clad with graded distribution of the refractive index that can be easily implemented practically was suggested and simulated in this work. The suggested design is compact, rapid, and is simple to be modified and tested. The simulated design contains a MZI of 1546.74 nm of central wavelength that is constructed using special type of double clad optical fiber that has two different numerical apertures. The first aperture will supply single mode propagation via its core, while the second numerical aperture supports a zigzag wave propagation (multimode) in the first clad region. The interferometer’s
... Show MoreVisible-light photodetectors constructed Fe2O3 were manufactured effectively concluded chemical precipitation technique, films deposited on glass substrate and Si wafer below diverse dopant (0,2,4,6)% of Cl, enhancement in intensity with X-ray diffraction analysis was showed through favored orientation along the (110) plane, the optical measurement presented direct allowed with reduced band gap energies thru variation doping ratio , current–voltage characteristics Fe2O3 /p-Si heterojunction revealed respectable correcting performance in dark, amplified by way of intensity of incident light, moreover good photodetector properties with enhancement in responsivity occurred at wavelength between 400 nm and 470 nm.