The current research dealt with the study of space compatibility and its role in enhancing the functional aspect of the design of the interior spaces of isolation hospitals by finding a system or format that is compatible with the nature of the changes occurring in the structure and function of the space system, as well as contributing to enhancing compatibility between the functional aspect and the interior space. Therefore, the designer must The interior is the study of the functional and spatial aspects as they are the basic aspects for achieving suitability, and through the interaction between the person and the place, the utilitarian performance characteristics are generated that the interior designer is interested in and tries to develop and give them the appropriate design fit. The research consists of four chapters:
* The first chapter: dealt with the research problem that was crystallized by the following question: “What is the role of spatial suitability in the process of change to embody the functional aspect of interior design?” The importance of the research is demonstrated by presenting a study necessitated by the necessity of raising the level of interior spaces, especially with regard to the issue of space suitability. The research also contributed to benefiting researchers and students regarding the results reached by the current research in the field of space suitability and confirming the functional aspect of interior design. The aim of the research is to clarify the role of adapting the interior space to the nature of the changes occurring in its systems and to confirm the functional aspect for which the space was designed. The first chapter also included the limits of the research (the objective limit, the spatial limit, the temporal limit) and the definition of terminology. The second chapter included the theoretical framework, which was divided into two sections, the first of which was: suitability, its concept, and its types. The second section was: the spatial organization of patient residence wards in hospitals
In this paper, a step-index fiber with core index 1.445 5 1 7 and cladding index 1.443 1 5 7 has been designed and studied. Multimode operation is achieved by using a fiber with core radius 25 μm operating at a wavelength of 1.3 μm. The mode parameters (effective refractive index, phase constant, fractional modal power in the core and cutoff wavelength) were calculated using RP fiber calculator (PRO version 2020). The shapes of the intensity and amplitude distribution of linearly polarized guided modes were shown.
Drilling well design optimization reduces total Authorization for Expenditures (AFE) by decreasing well constructing time and expense. Well design is not a constant pattern during the life cycle of the field. It should be optimized by continuous improvements for all aspects of redesigning the well depending on the actual field conditions and problems. The core objective of this study is to deliver a general review of the well design optimization processes and the available studies and applications to employ the well design optimization to solve problems encountered with well design so that cost effectiveness and perfect drilling well performance are achievable. Well design optimization processes include unconventional design(slimhole) co
... Show MoreThere is no doubt that optical fiber technology is one of the most important stages of the communications revolution at all and it is of utmost importance in our daily life. In this work, five fibers with core radii 2.5, 4.5 and 6.5–8.5 μm were designed. The properties of all guided modes have been calculated at a wavelength of 1550 nm by using RP Fiber Calculator. A single-mode fiber is obtained when the core radius approaches the wavelength. As the core radius is increased, the fiber becomes a multimode. The percentage power in the core increases with increasing core radius. The modes profiles were illustrated and compared with the modern references.
This paper presents L1-adaptive controller for controlling uncertain parameters and time-varying unknown parameters to control the position of a DC servomotor. For the purpose of comparison, the effectiveness of L1-adaptive controller for position control of studied servomotor has been examined and compared with another adaptive controller; Model Reference Adaptive Controller (MRAC). Robustness of both L1-adaptive controller and model reference adaptive controller to different input reference signals and different structures of uncertainty were studied. Three different types of input signals are taken into account; ramp, step and sinusoidal. The L1-adaptive controller ensured uniformly bounded
... Show MoreHygienic engineering has dedicated a lot of time and energy to studying water filtration because of how important it is to human health. Thorough familiarity with the filtration process is essential for the design engineer to keep up with and profit from advances in filtering technology and equipment as the properties of raw water continue to change. Because it removes sediment, chemicals, odors, and microbes, filtration is an integral part of the water purification process. The most popular technique for treating surface water for municipal water supply is considered fast sand filtration, which can be achieved using either gravity or pressure sand filters. Predicting the performance of units in water treatment plants is a basic pri
... Show More