Preferred Language
Articles
/
jcofarts-111
Reflection of political variables in the design of the Journal cover
...Show More Authors

the political changeable is important reflection in areas of life and the designers tried to high light it in the cover of Journal promised time Journal a fertile square to show reflection of political changeable, and triad  to  search  the  current  path. The  first  chapter organized according to axes, problem of  research formulated according to question:- what are reflections of political changeable in magazine cover?

    The importance of research depth of specialized approach on level of technical and stylistic as ago al ago as in: the baring of political changeable in design of journal's cover. The research moves in cognitive border from 2013 to 2017 and selection of time journal for research. The second chapter contains two sections: (political changeable) (journal's cover). Third chapter contains the clarification me the cites taken from descriptions method of work mechanical to reach results and identify to research community and sample select, tool research, sample analysis. Forth chapter isolated results, deductive, recommendations, proposals and results of conclusions were high tight as a follow:

     the reflections of political change able in Iraqi affairs, achieved on cover of time journal. Results of researcher concluded the reflection of variable in cover design of time journal according to method by politic of magazine in technic direction of  envelope. The designers depend on future political reading of events, then researcher recommended to take advantage the global design experience in designs of covers of journal. To add chapter proposals:

 

1- Reflection of cultural, art in design cover of Arabic journal.

2-Design systems, transformation in designs cover of Iraqi journal.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Nov 01 2011
Journal Name
International Journal Of Mechanical And Materials Engineering
Simulation and design optimization of magneto rheological control valve
...Show More Authors

Magneto-rheological (MR) Valve is one of the devices generally used to control the speed of Hydraulic actuator using MR fluid. The performance of valve depends on the magnetic circuit design. Present study deals with a new design of MR valve. The finite element analysis is carried out on this valve to optimize its design. The design of the magnetic circuit is accomplished by magnetic finite element software such as Finite Element Method Magnetic (FEMM). The Model dimensions of MR valve, material properties and the circuit properties of valve coil are taken into account. The results of analysis are presented in terms of magnetic strength and magnetic flux density. The valve can be operated with variable flow rate by varying the current. It i

... Show More
View Publication Preview PDF
Scopus (2)
Scopus
Publication Date
Sun Jun 01 2014
Journal Name
Baghdad Science Journal
(?m 10.6) Design study for Reserve of laser CO2
...Show More Authors

In this paper , the CO2 laser receiver system is designed and studied, with wavelength laser 10.6 ?m in room temperature , and to evaluate the performance and discussion it via the package of optical design (ZEMAX), from its output the Spot Diagram is measured through RMS ,and from the Ray fan plot , the aberrations is found which is the normal error for the best focus named (under corrected ) , the other output was the Geometric Encircled Energy in the spot diagram . and found that the radius of spot diagram at 80% (R80%) from the total energy ,and focal shift .The designed system have high efficiency and low cost .

View Publication Preview PDF
Crossref
Publication Date
Mon Feb 04 2019
Journal Name
Journal Of The College Of Education For Women
Computer-Aided-Design of low aberration electrostatic Immersion lens
...Show More Authors

A computerized investigation has been carried out to design an immersion lens
with low aberration operating under zero magnification condition using inverse problem.
The aberration is highly dependent on the shape of electrodes, for a preassigned electron
beam trajectory the paraxial-ray-equation is solved to determine the electrostatic potential
and field distribution.
From the knowledge of the potential and its first and second derivative the
electron optical properties were computed, the electrode geometry was determined from
the solution of Laplace equation.

View Publication Preview PDF
Publication Date
Tue Feb 28 2017
Journal Name
Journal Of Engineering
Design and Implementation of Enhanced Smart Energy Metering System
...Show More Authors

In this work, the design and implementation of a smart energy metering system has been developed. This system consists of two parts: billing center and a set of distributed smart energy meters. The function of smart energy meter is measuring and calculating the cost of consumed energy according to a multi-tariff scheme. This can be effectively solving the problem of stressing the electrical grid and rising consumer awareness. Moreover, smart energy meter decreases technical losses by improving power factor. The function of the billing center is to issue a consumer bill and contributes in locating the irregularities on the electrical grid (non-technical losses). Moreover, it sends the switch off command in case of the consumer bill is not

... Show More
View Publication Preview PDF
Publication Date
Mon Jul 10 2023
Journal Name
Journal Of Engineering
Design and Implementation of Single-Phase Boost PFC Converter
...Show More Authors

In this paper, a single-phase boost type ac-dc converter with power factor correction (PFC) technique is designed and implemented. A current mode control at a constant switching frequency is used as a control strategy for PFC converter. The PFC converter is a single-stage singleswitch boost converter that uses a current shaping technique to reshape the non-sinusoidal input current drawn by the bulky capacitor in the conventional rectifier. This technique should provide an input current with almost free-harmonics, comply with the IEC61000-3-2 limits, and a system operates with near unity power factor. The other function of the boost converter that should be
accomplished is to provide a regulated DC output voltage. The complete designed

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Sep 07 2008
Journal Name
Baghdad Science Journal
Design of Immersion Electrostatic LensOperated under Zero Magnification Condition
...Show More Authors

The inverse problem is important method in the design of electrostatic lenses which is used in this work, with new technique by suggesting an axial electrostatic potential distribution using polynomial functions of the third order. The paraxial-ray equation is solved to obtain the trajectory of particles that satisfy the suggested potential function.In this work design of immersion electrostatic lens operated under zero magnification condition. The electrode shape of sthe electrostatic lens was the dermined from the solution of laplace equation and plotted in two deimensions . The results showed low values of spherical and chromatic aberrations , which are considered as good criteria for good desigh.

View Publication Preview PDF
Crossref
Publication Date
Tue Dec 31 2019
Journal Name
Journal Of Engineering And Applied Sciences
Design and Implementation of Electronic Infrastructure for Academic Establishment
...Show More Authors

View Publication
Crossref
Publication Date
Sat Oct 04 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Estimation of some salivary variables and oral health status of patients with chronic myeloid leukemia aged 45-55 years
...Show More Authors

Background: Chronic myeloid leukemia is a cancer of the white blood cells characterized by the increased and unregulated growth of predominantly myeloid cells in the bone marrow. This study aimed to determine the effect of chronic myeloid leukemia on Dental caries and Oral health status including Gingivitis, Loss of attachment, Plaque index and Calculus index as well as evaluation of salivary flow rate and salivary interleukins-6 and tumor necrosis factor-?. Material and methods: Study group consisted of (75) subjects, (25) were newly diagnosed with chronic myeloid leukemia, (25) were taking medications (Glevic), and (25) were control subjects, all ag

... Show More
View Publication Preview PDF
Publication Date
Wed Jun 14 2023
Journal Name
Al-academy
Fractal and its implications for industrial product design
...Show More Authors

The current research dealt with the rapid development of industrial product design in recent times, and this development in the field of design led to the emergence of modern trends in many terms and theories to direct greater interest in the cognitive foundations of design and its relationship with the components of other natural sciences, and despite the impressive technological development, nature remains With its content of formative values and structural dimensions, it is the first source of inspiration and the source of all modern mathematical sciences and theories, as God made them tend towards organization to continue to provide us with endless inspiration. Hence, the fractional one, which is an important part of dedicating the d

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Aug 20 2021
Journal Name
Iraqi Journal Of Laser
Design of Tunable Optical Band Pass Filter based on in-Line PM-Mach Zehnder Interferometer
...Show More Authors

In this paper, tunable optical band-pass filters based on Polarization Maintaining Fiber –Mach Zehnder Interferometer presented. Tunability of the band-pass filter implemented by applying different mechanical forces N on the micro-cavities splicing regions (MCSRs). The micro-cavity formed by using three variable-lengths of single-mode polarization-maintaining fiber with (8, 16, 24) cm lengths, splice between two segments of (SMF-28) with (26, 13) cm lengths, using the fusion splicing technique.  Ellipsoidal shape micro-cavities experimentally achieved parallel to the propagation axis having dimensions between (12-24) μm of width and   (4-12) μm of length. A micro-cavity with width and length as high as 24 μm and 12 μ

... Show More
View Publication Preview PDF