Preferred Language
Articles
/
jcofarts-1069
Active design and its principles in industrial product design
...Show More Authors

 The problem of the research came through the following question (what is the effectiveness of active design in contemporary industrial products), and it emphasized the importance of research to make society with its members in a positive state of activity, and what can help the industrial product design to achieve this, but the goal of the study is (determining the characteristics and principles of design Active and its effectiveness in the industrial product), and the study was determined by industrial products related to daily, recreational and sports activity, The researcher relied on a form to determine the axes of analysis for the sample models, in order to reach the results of the research, the most important of which are: Realize the principles of active design by finding structural and organizational features and adapting to the context of use.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri May 03 2019
Journal Name
Photonics
Design Investigation of 4 × 4 Nonblocking Hybrid Plasmonic Electrooptic Switch
...Show More Authors

This paper proposes a compact, plasmonic-based 4 × 4 nonblocking switch for optical networks. This device uses six 2 × 2 plasmonic Mach-Zehnder switch (MZS), whose arm waveguide is supported by a JRD1 polymer layer as a high electro-optic coefficient material. The 4 × 4 switch is designed in COMSOL environment for 1550 nm wavelength operation. The performance of the proposed switch outperforms those of conventional (nonplasmonic) counterparts. The designed switch yields a compact structure ( 500 × 70   µ m 2 ) having V π L = 12   V · µ m , 1.5 THz optical bandwidth, 7.7 dB insertion loss, and −26.5 dB crosstalk. The capability of the switch to route 8 × 40 Gbps WDM signal is demonstrated successfully.

... Show More
View Publication
Scopus (3)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Sun Jan 14 2018
Journal Name
Journal Of Engineering
Second Order Sliding Mode Controller Design for Pneumatic Artificial Muscle
...Show More Authors

In this paper, first and second order sliding mode controllers are designed for a single link robotic arm actuated by two Pneumatic Artificial Muscles (PAMs). A new mathematical model for the arm has been developed based on the model of large scale pneumatic muscle actuator model. Uncertainty in parameters has been presented and tested for the two controllers. The simulation results of the second-order sliding mode controller proves to have a low tracking error and chattering effect as compared to the first order one. The verification has been done by using MATLAB and Simulink software.

 

View Publication Preview PDF
Publication Date
Sun Feb 01 2015
Journal Name
Journal Of Engineering
Design a Multi-Choice Fuzzy Control System of the Greenhouse
...Show More Authors

Applications of nonlinear, time variant, and variable parameters represent a big challenge in a conventional control systems, the control strategy of the fuzzy systems may be represents a simple, a robust and an intelligent solution for such applications.

This paper presents a design of fuzzy control system that consists of three sub controllers; a fuzzy temperature controller (FC_T), a fuzzy humidity controller (FC_H) and a ventilation control system; to control the complicate environment of the greenhouse (GH) using a proposed multi-choice control system approach. However, to reduce the cost of the crop production in the GH, the first choice is using the ventilation system to control the temperature and humidit

... Show More
View Publication Preview PDF
Publication Date
Wed Nov 01 2017
Journal Name
Journal Of Engineering
Design of L1 -Adaptive Controller for Single Axis Positioning Table
...Show More Authors

L1 adaptive controller has proven to provide fast adaptation with guaranteed transients in a large variety of systems. It is commonly used for controlling systems with uncertain time-varying unknown parameters. The effectiveness of  L1 adaptive controller for position control of single axis has been examined and compared with Model Reference Adaptive Controller (MRAC). The Linear servo motor is one of the main constituting elements of the x-y table which is mostly used in automation application. It is characterized by time-varying friction and disturbance.

    The tracking and steady state performances of both controllers have been assessed fo

... Show More
View Publication Preview PDF
Publication Date
Sat Jan 01 2022
Journal Name
Technologies And Materials For Renewable Energy, Environment And Sustainability: Tmrees21gr
Optical characteristics of simulated design of parabolic trough solar concentrator
...Show More Authors

View Publication
Crossref (3)
Crossref
Publication Date
Fri Dec 03 2021
Journal Name
2021 4th International Conference On Advanced Communication Technologies And Networking (commnet)
Methodology for Predicting the Optimum Design of Radio-Electronic Devices
...Show More Authors

View Publication
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Fri Apr 01 2022
Journal Name
Telkomnika (telecommunication Computing Electronics And Control)
An adaptive neural control methodology design for dynamics mobile robot
...Show More Authors

View Publication
Scopus (10)
Crossref (7)
Scopus Crossref
Publication Date
Tue Nov 09 2021
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
Strategic leadership and its role in achieving competitiveness in industrial establishments": "A field study in Bashir Al-Siksik & Co. for the manufacture of sanitary and plastic tools
...Show More Authors

This study aims to know the role of strategic leadership to achieving competitiveness in industrial establishments by identifying the respondents’ perceptions about the level of availability of dimensions of leadership strategies (creativity and innovation, risk tolerance, available opportunities) in Bashir Al-Siksek & Partners Company for the manufacture of sanitary and plastic ware in Gaza strip

To achieve this, a questionnaire was developed and distributed to a sample of managers, auditors, accountants, and administrative employees in the study sample company. The questionnaire tool was distributed to 60 employees and employees, of which (52) were retrieved, or 86.6%, and (8) were excluded for la

... Show More
View Publication Preview PDF
Publication Date
Sun Sep 15 2019
Journal Name
Al-academy
Use of Multimedia in the Design of Educational Websites and their Role in Enhancing the Cognitive Aspect of the Learner: احمد ناجي علي-يوسف مشتاق لطيف
...Show More Authors

Multimedia is one of the most important elements of modern educational media and must be used in educational websites in order to disseminate knowledge on a large scale and should be used to provide scientific information to all, as the current research tried to explore the possibilities of employing them in the design of educational websites and highlight their role in promoting the scientific aspects of the user. This study included four axes, the first of which was devoted to the introduction which includes the problem of research, its importance, objectives and its objective, temporal and spatial limitations, which were limited to the study of the main pages of Arabic educational websites published in 2019.  The second axis cont

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Oct 16 2025
Journal Name
Pharmacia
Design and evaluation of a mucoadhesive gel-forming spray for local delivery of betamethasone sodium phosphate in aphthous ulcer management
...Show More Authors

Mouth ulcers are common oral lesions. Although several topical treatments are commercially available, their limited residence time requires frequent application, which remains a significant drawback. This study aimed to develop a novel mucoadhesive, thermosensitive, in situ gel-forming spray for local delivery of betamethasone sodium phosphate, thereby reducing systemic exposure. Formulations were optimized using the design of experiment approach to investigate the effects of thermosensitive polymers (Poloxamer 407 and Poloxamer 188), mucoadhesive polymer (hyaluronic acid), and drug incorporation on gelation temperature and time. The optimized formulation gelled at 33.3 ± 0.7 °C within 14.79 ± 1.87 s and showed a spray angle of 4

... Show More
View Publication Preview PDF
Scopus Crossref