The present study aims at examining quantitatively the morphometric characteristics of Iziana Valley basin that is located in the northern part of Iraq; particularly in south of Erbil Governorate. This basin is considered one of the small sub-basins where its valleys run on formations of the Triple and Quadrant Ages, which are represented by the Bay Hassan formations, and the sediments and mixed sediments of the cliffs, respectively. The area of the Iziana basin amounts to (36.39 km2) whereas the percentage of its rotation reaches (0.17); a low percentage, which indicates that the basin diverges from the circular to the rectangular shape. The value of the elongation ratio of the basin reaches (0.38) while the terrain ratio of the basin is (0.03), a low percentage that entails the weakness of its erosion processes and the small volume of the carried and transported sediments. As for the relative topography of the basin, it was (1.08), which is also a low value. It indicates a relatively large area of the basin and the impressive strides that it has made in its erosion cycle. The total river levels of the basin reach (5) ranks, and their numbers vary from one rank to another. Moreover, the total length of the drainage networks in the basin reached (187.4 km), and the prevailing drainage patterns in the basin are the tree and parallel patterns. The researcher has adopted spatial, formal, topographical, and river net-work properties for the purpose of first determining the shape of the basin, the stage of its erosion, its secondary basins, and its terrestrial features that have been developed as a result of the contrast between the erosion and sedimentation processes.
Two homopolymeric and three copolymeric additives for base oil were synthesized using octyl acrylate (OA) and tert-butyl acrylamide (TBA) monomers. The two additives named P1 and P2 are the homopolymers of TBA and OA, respectively, whereas copolymeric additives named Co1, Co2, and Co3 were synthesized by varying the ratios of TBA:OA as 1:3, 3:1 and 1:1, respectively. The prepared polymers were characterized by Fourier Transform Infrared (FTIR). Based on the solubility of synthesized polymers in base oil and reactivity ratios of TBA/OA copolymer (0.222, 0.434) calculated by Fineman-Ross method, P2, Co1, Co2 and Co3 were selected to evaluate their performance as pour point depressant (PPD), viscosity improver (VII), and anticorrosion addit
... Show MoreBackground: There are many congenital anomalies associated with cleft lip and/or palate. This research is to study the prevalence of congenitally missing teeth and supernumerary teeth in this population group. Materials and Method: One hundred eight cleft lip and/or palate Iraqi patients had participated in this study (57 male, 51 female), 3-12 years of age. 26 of them had orthopantomogram were within (6-12) years of age were inspected for congenitally missing teeth and supernumerary teeth. Patients whom age range 3-5 years were checked for the congenitally missing teeth by clinical examination with strongly insisting the teeth were not missed due to caries or trauma. Results: There were 19(73.076%) patients with 41 congenitally missing tee
... Show MoreTransition metal complexes of Y(III), La(III) and Rh(III) with azo dye 2,4-dimethyl-6- (4-nitro-phenylazo)-phenol derived from 4-nitroaniline and 2,4-dimethylphenol were synthesized. Characterization of these compounds has been done on the basis of elemental analysis, electronic data, FT-IR,UV-Vis and 1HNMR, as well as conductivity measurements. The nature of the complexes formed were studies following the mole ratio and continuous variation methods, Beer's law obeyed over a concentration range (1x10-4- 3x10-4). High molar absorbtivity of the complex solutions were observed. From the analytical data, the stoichiomerty of the complexes has been found to be 1:3 (Metal:ligand). On the basis of Physicochemical data octahedral geometries were as
... Show MoreBackground: The long term survival of dental implants is evaluated by the amount of crestal bone loss around the implants. Some initial loss of bone around dental implants is generally expected. There is reason to believe that reflecting a mucoperiosteal flap promotes crestal bone loss in the initial phase after an implant has been inserted. The surgical placement of a dental implant fixture is constantly changing and in recent years, there has been some interest in developing techniques that minimize the invasive nature of the procedure, with flapless implant surgery being advocated. The purpose of this study was to compare the radiographic level of the peri- implant bone after implant placement between traditional flapped surgery and f
... Show MoreBackground: This study aimed to determine the value of Beta angle for a sample of Iraqi adults with class I skeletal and dental relations and to verify the existence of sexual dimorphism and to find out the relation between this angle and other craniofacial measurements. Materials and Methods: Sixty dental students (23 males and 37 females) with an age ranged between 20-31 years old and having class I skeletal and dental relations were chosen for this study. Each student was subjected to clinical examination and digital true lateral cephalometric radiograph. The radiographs were analyzed using AutoCAD 2007 computer program to measure the angular and linear variables. Descriptive statistics were obtained for the measurements for both genders
... Show MoreThe removal of heavy metal ions from wastewater by ion exchange resins ( zeolite and purolite C105), was investigated. The adsorption process, which is pH dependent, shows maximum removal of metal ions at pH 6 and 7 for zeolite and purolite C105 for initial metal ion
concentrations of 50-250 mg/l, with resin dose of 0.25-3 g. The maximum ion exchange capacity was found to be 9.74, 9.23 and 9.71 mg/g for Cu2+, Pb2+, and Ni2+ on zeolite respectively, while on purolite C105 the maximum ion exchange capacity was found to be 9.64 ,8.73 and 9.39 for Cu2+, Pb2+, and Ni2+ respectively. The maximum removal was 97-98% for Cu2+ and Ni2+ and 92- 93% for Pb2+ on zeolite, while it was 93-94% for Cu2+, 96-97% for Ni2+, and 87-88% for Pb2+ on puroli
Continuous turbidimetric analysis (CTA) for a distinctive analytical application by employing a homemade analyser (NAG Dual & Solo 0-180°) which contained two consecutive detection zones (measuring cells 1 & 2) is described. The analyser works based on light-emitting diodes as a light source and a set of solar cells as a light detector for turbidity measurements without needing further fibres or lenses. Formation of a turbid precipitated product with yellow colour due to the reaction between the warfarin and the precipitation reagent (Potassium dichromate) is what the developed method is based on. The CTA method was applied to determine the warfarin in pure form and pharmaceu
Mn2O3 was coated onto reduced titania nanotubes by reverse pulse electrodeposition, showing smooth and homogenous deposits without covering the opening of the nanotubes.