This study aims to create spatial balance between two Iraqi writers' novels (Maysaloon
Hadi, Alya Talib) technical and objective illustrates similarity points and difference in the
writers' style. We depended in our research on spatial classification considering the aggressive
and friendly, since the writers focused on them.
The research study concluded to many sides, some of which are similar and some are
different. Firstly, ingenuity description of the writers. Followed by the deep connection they
have. Because of the personal experience it emanated from alienation sensations and nostalgia
to deep roots to homeland.
On the other hand, difference aspects, we see Maysaloon takes symbols and illusions
unlike Alya which was her style close to smooth and empty from deception. The character of
prevailing on (Shai Al-Aroos) novel is objectively, while we see Alia is moving to
subjectively, Maysaloon focused on central character while showing personal same writer
with Alia Talib. It is a documentary novel.
Al-Yaqubi was biased in favor of Shia. May be du to his choice of source, materials. All historians as with other human beings are biased in their attitudes and preconceptions in one degree or another as well as in one direction or another.
The choice of source materials, their nature and the use made of them is an important index for measuring the achievement of ang historian.
Several specific questions arise. What sources did author use that were either unknown to or were not employed by his predecessors and contemporaries for whatever reason?
What sources are common to al- Yaqubi and his colleagues among the early Arab historians and what evidence of tendentiousness can be ascert- ained in these? To what extent can the author
High-performance liquid chromatographic methods are used for the determination of water-soluble vitamins with UV-Vis. Detector. A reversed-phase high-performance liquid chromatographic has been developed for determination of water-soluble vitamins. Identification of compounds was achieved by comparing their retention times and UV spectra with those of standards solution. Separation was performed on a C18 column, using an isocratic 30% (v/v) acetonitril in dionozed water as mobile phase at pH 3.5 and flow rate 1.0m/min. The method provides low detection and quantification limits, good linearity in a large concentration interval and good precision. The detection limits ranged from 0.01 to 0.025µg/ml. The accuracy of the method was
... Show MoreIn this paper, turbidimetric and reversed-phase ultra-fast liquid chromatography (UFLC) methods were described for the quantitative determination of ephedrine hydrochloride in pharmaceutical injections form. The first method is based on measuring the turbidimetric values for the formed yellowish white precipitate in suspension status in order to determine the ephedrine hydrochloride concentration. The suspended substance is formed as a result of the reaction of ephedrine hydrochloride with phosphomolybdic acid which was used as a reagent. The physical and chemical characteristics of the complex were investigated. The calibration graphs of ephedrine were established by turbidity method. While the second method (UFLC) was conducted using the
... Show More4 Blood Res 2018;53:314-319. Received on August 11, 2018 Revised on August 30, 2018 Accepted on August 30, 2018 Background Iron overload is a risk factor affecting all patients with thalassemia intermedia (TI). We aimed to determine whether there is a relationship of serum ferritin (SF) and alanine ami- notransferase (ALT) with liver iron concentration (LIC) determined by R2 magnetic reso- nance imaging (R2-MRI), to estimate the most relevant degree of iron overload and best time to chelate in patients with TI. Methods In this cross-sectional study, 119 patients with TI (mean age years) were randomly se- lected and compared with 120 patients who had a diagnosis of thalassemia major (TM). Correlations of LIC, as determined by R2-MRI, with SF
... Show MoreA chemometric method, partial least squares regression (PLS) was applied for the simultaneous determination of piroxicam (PIR), naproxen (NAP), diclofenac sodium (DIC), and mefenamic acid (MEF) in synthetic mixtures and commercial formulations. The proposed method is based on the use of spectrophotometric data coupled with PLS multivariate calibration. The Spectra of drugs were recorded at concentrations in the linear range of 1.0 - 10 μg mL-1 for NAP and from 1.0 - 20 μg mL-1 for PIR, DIC, and MEF. 34 sets of mixtures were used for calibration and 10 sets of mixtures were used for validation in the wavelength range of 200 to 400 nm with the wavelength interval λ = 1 nm in methanol. This method has been used successfully to quant
... Show MoreObjectives: acute kidney injury (AKI) is a serious pathophysiology side effect of rhabdomyolysis. Inflammatory mechanisms play a role in the development of rhabdomyolysis-induced AKI. Citronellol (CT) is a naturally occurring monoterpene alcohol (3,7-Dimethyl-6-often-1-ol) found in aromatic plant species' essential oils. In this study, we explored the protective effects of Citronellol on glycerol-induced AKI.
Methods: Four groups of eight mice each (n=8) were formed by randomly dividing the animals into the groups, glycerol-induced AKI model group, low-dose CT-treated group (50mg/kg), high-dose CT-treated group (100mg/kg), and control group. The renal functions of mice from all groups were evalua
... Show MoreThe electrochemical polymerization of the monomer sulfanilamide (SAM) in an aqueous solution at room temperature produces polysulfanilamide (PSAM). The Fourier Transform Infrared spectroscopy (FTIR) was used to investigate the properties of the prepared polymer layer that generated on the stainless steel (St.S) surface (working electrode) and Atomic Force Microscope (AFM) was used to characterize the morphology, topology, and detailed surface structure of polymer layer that generated on the surface. The corrosion behavior of uncoated and coated St.S were evaluated by using the electrochemical polarization method in a 0.2 M HCl solution and a temperature range of 293–323 K, the anticorrosion action of the polymer coating on stainless steel