Preferred Language
Articles
/
jbcd-967
An Evaluation of Ion Released from Two Brands of Brackets in Three Types of Mouthwashes
...Show More Authors

Background: Mouthwashes used widely as ancillary to mechanical oral hygiene methods. Little information provided about the effect of mouthwashes on ions released from orthodontic brackets. Therefore, the present study has been established to evaluate the effect of different mouthwashes on the corrosion resistance and the biocompatibility of two brands of brackets. Materials and Methods: Eighty premolar stainless steel brackets were used (40 brackets from each brand). They were subdivided into four subgroups (n=10) according to immersion media (deionized distilled water, Corsodyl, Listerine and Silca herb mouthwashes). Each bracket was stored in a closely packed glass tube filled with 15ml of the immersion media and incubated for 45 days at 37ºC. Then chromium, nickel, copper and manganese ions release were measured using Atomic absorption spectrophotometer, while iron ions release were measured by using Iron kit and spectrophotometer. For statistical analysis, t-test, analysis of variance (ANOVA) and least significant difference (LSD) were used. Results: The results revealed that the ions released from Dentaurum brackets were significantly higher than that from OrthoTechnology brackets in all type of immersion media except for Chromium ions in Corsodyl mouthwash. The release of copper and chromium ions was significantly higher in Listerine and Corsodyl mouthwashes than in deionized distilled water being related to the pH of the immersion media. While, the release of iron, nickel and manganese ions in the three mouthwashes was comparable to that in deionized distilled water. Conclusions: The amounts of released ions were below toxic levels and did not exceed the daily dietary intake, but it may be recommended to avoid prolonged use of Listerine and Corsodyl mouthwashes in patients allergic to chromium.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Sep 27 2025
Journal Name
Journal Of Baghdad College Of Dentistry
An Evaluation of Corrosion Pits in Esthetic Coated Stainless Steel Orthodontic Archwires in Dry and Wet Environment at Different Intervals (An In Vitro Study)
...Show More Authors

Background: The demand for esthetic orthodontic appliances is increasing; so the esthetic orthodontic archwires were introduced. Among them, Teflon and Epoxy coated stainless steel archwires. The amount of force available from the archwire depends on the structural properties and susceptibility to corrosion. All metallic alloys are changed during immersion in artificial saliva, chlorhexidine mouthwash andtoothpaste, but their behaviors differ from one type to another. They corrode at different rates, which lead to decrease the amount of force applied to the teeth. This in vitro study was designed to evaluate the corrosion pits in stainless steel archwires coated with Teflon and with Epoxy in dry and after immersion in artificial saliva, chl

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Sci.int.(lahore)
SOME NEW TYPES OF PERFECT MAPPINGS
...Show More Authors

In this work, we introduce a new kind of perfect mappings, namely j-perfect mappings and j-ω-perfect mappings. Furthermore we devoted to study the relationship between j-perfect mappings and j-ω-perfect mappings. Finally, certain theorems and characterization concerning these concepts are studied; j = , δ, α, pre, b, β

Preview PDF
Publication Date
Sat Sep 27 2025
Journal Name
Al-rafidain University College For Sciences
Uncertainty types and theories of treatment
...Show More Authors

In this research the researcher had the concept of uncertainty in terms of types and theories of treatment and measurement as it was taken up are three types of indeterminacy and volatility and inconsistency

View Publication Preview PDF
Publication Date
Sun Sep 25 2022
Journal Name
American Scientific Research Journal For Engineering, Technology, And Sciences
Design and Fabrication of an Electromechanical Tester to Perform Two-dimensional Tensile Testing for Flexible Materials
...Show More Authors

There are many diseases that affect the arteries, especially those related to their elasticity and stiffness, and they can be guessed by estimating and calculating the modulus of elasticity. Hence, the accurate calculation of the elastic modulus leads to an accurate assessment of these diseases, especially in their early stages, which can contribute to the treatment of these diseases early. Most of the calculations used the one-dimensional (1D) modulus of elasticity. From a mechanical point of view, the stresses to which the artery is subjected are not one-dimensional, but three-dimensional. Therefore, estimating at least a two-dimensional (2D) modulus of elasticity will necessarily be more accurate. To the knowledge of researchers, there i

... Show More
Preview PDF
Publication Date
Sun Dec 01 2019
Journal Name
Zeitschrift Für Assyriologie Und Vorderasiatische Archäologie
Literary Texts from the Sippar Library I: Two Babylonian Classics
...Show More Authors
Abstract<p>Publication and edition of two tablets from the library in the Ebabbar Temple of Sippar, a manuscript of the ‘Babylonian Poem of the Righteous Sufferer’ (<italic>Ludlul bēl nēmeqi</italic>) Tablet III, and a manuscript of the long prayer to Marduk ‘Furious Lord’ (also known as ‘Marduk 1’).</p>
View Publication
Scopus (6)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Wed Jun 20 2018
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Synthesis, Characterization and Antimicrobial Evaluation with DFT Study of New Two-Amino-4-(4-Chlorophenyl) Thiazole Derivatives
...Show More Authors

2-amino-4-(4-chloro phenyl)-1,3-thiazole (1) was synthesized by refluxing thiourea with para-chloro phenacyl bromide in absolute methanol. The condensation of amine compound (1)  with phenylisothiocyanate in the presence of pyridine will  produce 1-(4-(4-chlorophenyl)thiazol-2-yl)-3-phenylthiourea(2), which is  upon treatment with 2,4 dinitrophenyl hydrazine by conventional method, afforded 1- ( 4 - ( 4 – chlorophenyl ) thiazol – 2 – yl ) – 3 - phenylhydrazonamide,N' - ( 2 , 4 -dinitrophenyl) ,(3).The characterization of the titled compounds were performed utilizing FTIR spectroscopy, 1HNMR and CHNS elemental analysis, and by me

... Show More
View Publication Preview PDF
Scopus (7)
Crossref (2)
Scopus Crossref
Publication Date
Sat Jul 01 2023
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
The market value between the two dilemmas of profit distribution and retention: an analytical study in the Iraqi stock market
...Show More Authors

Abstract:

             The distribution or retention of profits is the third decision among financial management decisions in terms of priority, whether at the level of theory or practice, as the issue of distribution or retention is multi-party in terms of influence and impact, as determining the optimal percentage for each component is still the subject of intellectual debate because these decisions are linked to the future of the organization and several considerations, The research focus on the nature of the policies followed by the Iraqi banking sector As the sample chosen by the intentional sampling method was represented by the Commercial Bank of

... Show More
View Publication Preview PDF
Publication Date
Sat Sep 27 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The Marginal Fitness of CAD/CAM All Ceramic Crowns Constructed by Two Typesof Direct Digitization Techniques (An In Vitro Study)
...Show More Authors

Background: In capturing a negative image, the digital impression secures a digital record for the purposeof designing and creating restorations. The introduction of scanning system presents a paradigm shift in the way of the dental impression procedure and encourages the accuracy of obtained restoration especially in the marginal area as a result of producing accurate final impression The digital system offers many advantages over the Conventional method.. The objective of this present in vitro study was to evaluate the marginal fitness of all ceramic crowns fabricated by direct digital scanning of the prepared tooth using two types of intra-oral cameras (Bluecam camera with strip light projection technique and Omnicam camera with video sa

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Fri Sep 01 2023
Journal Name
Al-khwarizmi Engineering Journal
Removal of Ciprofloxacin Antibiotic from Synthesized Aqueous Solution Using Three Different Metals Nanoparticles Synthesized Through the Green Method
...Show More Authors

This study investigates the possibility of removing ciprofloxacin (CIP) using three types of adsorbent based on green-prepared iron nanoparticles (Fe.NPs), copper nanoparticles (Cu. NPS), and silver nanoparticles (Ag. NPS) from synthesized aqueous solution. They were characterized using different analysis methods. According to the characterization findings, each prepared NPs has the shape of a sphere and with ranges in sizes from of 85, 47, and 32 nanometers and a surface area of 2.1913, 1.6562, and 1.2387 m2/g for Fe.NPs, Cu.NPs and Ag.NPs, respectively. The effects of various parameters such as pH, initial CIP concentration, temperature, NPs dosage, and time on CIP removal were investigated through batch experiments. The res

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (3)
Scopus Crossref
Publication Date
Tue Jan 08 2019
Journal Name
Iraqi Journal Of Physics
Radioactivity and annual effective dose in some types of drug
...Show More Authors

The aim of this research is to know danger of radioactive isotopes
that are found in samples of drugs traded in Iraqi markets. The
samples are Iraqi Amoxicillin, English Amoxicillin, UAE
Amoxicillin, Indian Amoxicillin, Iraqi Paracetamol, English
Paracetamol, UAE Paracetamol and Indian Paracetamol. By high
purity germanium the activity of the following isotopes 40K, 214Pb,
228Ac and 137Cs is measured and the specific activity was used to
calculate the annual effective dose. Then the calculated annual
effective dose values are compared with the allowable annual
effective dose values of each part of digestive channel. This research
concluded that the measured annual effective dose values are not
dangerous.<

... Show More
View Publication Preview PDF
Crossref