Background: An accurate adaptation of the crown to the finish line is essential to minimize cement dissolution and to preserve periodontium in fixed partial denture cases. An accurate adaptation of crown is possible only when preparation details are captured adequately in the impression and transferred to cast. For these reasons, gingival displacement is necessary to capture subgingival preparation details.The aim of the present study is to measure in vivo the horizontal displacement of the gingival sulcus obtained by using three new cordless retraction materials (Magic Foam Cord®, Racegel and Astringent Retraction Paste) in comparison to medicated retraction cord. Materials and method: Thirty-two patients requiring porcelain fused to metal fixed partial denture for replacement of a missing maxillary posterior tooth (either one of thepremolars or the first molar). The patients are randomly divided into four groups of eight patients each according to the type of gingival retraction material used as follows: Group I: Medicated retraction cord (racemic epinephrine hydrochloride 0.3 ± 0.2 mg per inch of cord, #00), Group II: Magic Foam Cord® (expanding polyvinyl siloxane), Group III: Racegel (25% aluminum chloride gel) and Group IV: Astringent Retraction Paste (15% aluminum chloride paste). Three depth orientation grooves were prepared in the buccal and palatal surfaces of a maxillary premolar parallel with the long axis of the tooth, extending from the middle third to the gingival third with the level of the free gingiva using a flat-ended diamond fissure bur. Impression of the gingival sulcus was then made using monophase polyether impression material (Impregum™ Penta™ Soft, 3M ESPE, Germany), before and after gingival retraction with either of the aforementioned gingival retraction materials. The sulcus width, before and after gingival retraction was measured on the master cast (in µm), after its sectioning longitudinally bucco-palatally at the middle of the prepared grooves using a rotary diamond disc. The measurement carried out by using digital microscope (Dino-Lite)at a magnification of 230X. The horizontal gingival displacement (the distance from the end of each prepared groove to the crest of the gingiva) measured by subtracting the gingival sulcus width after retraction from that before retraction. Results: The findings of the present study showed that the highest mean of horizontal gingival displacement is recorded by Group IV (Astringent Retraction Paste) (250.7900 µm), whereas the lowest mean of horizontal gingival displacement is recorded by Group III (Racegel) (78.0988 µm). One-way ANOVA test showed statistically highly significant differences among groups (p< 0.01). Least Significant Difference test (LSD test) was also used to make multiple comparisons among groups and revealed a statistically highly significant difference between each two groups (p< 0.01). Conclusion: The two new gingival retraction pastes (Astringent Retraction Paste and Magic Foam Cord®) could be used for gingival retraction as alternatives to medicated retraction cord. They offer advantages of simplified placement technique and shorter application time with greater gingival retraction. Meanwhile, the use of Racegel alone is not recommended for gingival retraction since it provides the least gingival displacement.
The research aims to get acquainted with the evaluation of the reality of the application of the curriculum axis from among the eight Iraqi academic accreditation standards in a sample of governmental and private universities and colleges in Iraq and to identify the main and secondary reasons for it as well as to provide proposed mechanisms and procedures to help reduce gaps, If the research problem is represented in the weak availability of the requirements of the curriculum axis in universities and colleges (the study sample) due to the weak documentation and successful implementation of them and interest in them is still below the level of ambition, In order to arrive at scientific facts, the researchers adopted the comparativ
... Show MoreBackground: Bone augmentation techniques are commonly employed in medical fields. This biomaterial system must be readily available, easily applicable by minimally-invasive technique and able to release an osteoinductive growth factor. Such a system will be able to engineer new bone formation locally at the site of injection. Hyaluronic acid has osteogenic potential that can be exploited not only for repairing bone defects but also for providing transplantable bone for the reconstruction of a variety of bone defects. The aims of this study were to evaluate the effects of Hyaluronic acid gel on bone healing by immunohistochemical estimation of transforming growth factor -beta 3 in experimental and control groups. Materials and methods: Thirt
... Show MoreMycotoxins are secondary by-products of mold metabolism and are accountable for human and animal mycotoxicosis. The most serious trichothecenic mycotoxin is the fungal T-2 mycotoxin. T-2 mycotoxin impaired nutrient absorption, metabolism, and then, eliciting severe oxidoreductive stress. Diet plays a key role beyond the supply of nutrients in order to promote animal and human health. Organic acids have been commonly used to exert antioxidative stress capacity in the liver and gut ecosystem. This study is planned to explore, the competence of using (X-MoldCid®) during chronic T-2 mycotoxicosis course in rat. Rats were allocated into 4 main groups, (CN-Gr), negative control and was allowed for the free access to the normal rats chow and the
... Show MoreBackground: The displacement of artificial teeth during complete denture construction presents major processing errors in the occlusal vertical dimension which were verified at the previous trial denture stage. The aim of this study was to assess the effect of delay in processing after final flask closure and tension application on the vertical acrylic and porcelain teeth displacement of complete dentures constructed from heat cured acrylic and the results were compared with the conventional processing method. Materials and methods: forty samples of identical maxillary complete dentures were constructed from heat polymerized acrylic resin. These samples were subdivided into the following experimental subgroups in which each subgroup contai
... Show MoreThe current research aims to identify "the impact of the round table strategies and the question of self-achievement and self-efficacy among students of the Faculty of Education in research methodology course.” The research sample consisted of (75) male and female-third stage students in the department of Life Sciences / College of Education for Pure Sciences / University of Dhi Qar for the academic year (2018-2019. The researcher adopted the experimental approach to achieving the study objectives. The researcher prepared two tools: the achievement test and the self-efficacy scale were applied to the collected sample to obtain the needed data. The result showed that there was a statistically significant difference at the level (0.05) b
... Show MoreBig developments in technology have led to upset the balance of ideas, given of its own post new properties for products not provided by traditional technology, especially economic units operating within the industrial sector, and therefore it is important to develop the Iraqi industrial sector and interest to do its vital role in light Of progress technological, and the cost accounting has benefited from this technology to development its goals in the regulatory process through the use of non-destructive evaluation perspective in carrying out its functions and to provide appropriate assistance for the use of the products, which were traditional accounting does not take them into consideration. The research aims to a statement that the u
... Show MoreThe factors influencing the financial market are rapidly becoming more complex. The impact of non-financial factors on the performance of a company’s common stock can increase in ways that were not previously expected. This study investigated how brand capital affects the risk of stock prices in Iraqi private banks listed on the Iraq Stock Exchange failing by identifying the likelihood of a crash caused by a negative deviation in the distribution of returns on ordinary shares. As a result, the current study’s concept is to review an analytical knowledge framework of the nature of that relationship, its changes, and its impact on the pricing of ordinary shares of the banks of the researched sector for the years 2009 to 2017, as w
... Show More