Preferred Language
Articles
/
jbcd-946
An Evaluation of the Efficacy of Different Gingival Retraction Materials on the Gingival Tissue Displacement (A Comparative In Vivo Study)
...Show More Authors

Background: An accurate adaptation of the crown to the finish line is essential to minimize cement dissolution and to preserve periodontium in fixed partial denture cases. An accurate adaptation of crown is possible only when preparation details are captured adequately in the impression and transferred to cast. For these reasons, gingival displacement is necessary to capture subgingival preparation details.The aim of the present study is to measure in vivo the horizontal displacement of the gingival sulcus obtained by using three new cordless retraction materials (Magic Foam Cord®, Racegel and Astringent Retraction Paste) in comparison to medicated retraction cord. Materials and method: Thirty-two patients requiring porcelain fused to metal fixed partial denture for replacement of a missing maxillary posterior tooth (either one of thepremolars or the first molar). The patients are randomly divided into four groups of eight patients each according to the type of gingival retraction material used as follows: Group I: Medicated retraction cord (racemic epinephrine hydrochloride 0.3 ± 0.2 mg per inch of cord, #00), Group II: Magic Foam Cord® (expanding polyvinyl siloxane), Group III: Racegel (25% aluminum chloride gel) and Group IV: Astringent Retraction Paste (15% aluminum chloride paste). Three depth orientation grooves were prepared in the buccal and palatal surfaces of a maxillary premolar parallel with the long axis of the tooth, extending from the middle third to the gingival third with the level of the free gingiva using a flat-ended diamond fissure bur. Impression of the gingival sulcus was then made using monophase polyether impression material (Impregum™ Penta™ Soft, 3M ESPE, Germany), before and after gingival retraction with either of the aforementioned gingival retraction materials. The sulcus width, before and after gingival retraction was measured on the master cast (in µm), after its sectioning longitudinally bucco-palatally at the middle of the prepared grooves using a rotary diamond disc. The measurement carried out by using digital microscope (Dino-Lite)at a magnification of 230X. The horizontal gingival displacement (the distance from the end of each prepared groove to the crest of the gingiva) measured by subtracting the gingival sulcus width after retraction from that before retraction. Results: The findings of the present study showed that the highest mean of horizontal gingival displacement is recorded by Group IV (Astringent Retraction Paste) (250.7900 µm), whereas the lowest mean of horizontal gingival displacement is recorded by Group III (Racegel) (78.0988 µm). One-way ANOVA test showed statistically highly significant differences among groups (p< 0.01). Least Significant Difference test (LSD test) was also used to make multiple comparisons among groups and revealed a statistically highly significant difference between each two groups (p< 0.01). Conclusion: The two new gingival retraction pastes (Astringent Retraction Paste and Magic Foam Cord®) could be used for gingival retraction as alternatives to medicated retraction cord. They offer advantages of simplified placement technique and shorter application time with greater gingival retraction. Meanwhile, the use of Racegel alone is not recommended for gingival retraction since it provides the least gingival displacement.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Nov 01 2015
Journal Name
Journal Of Engineering
Vibration analysis of angle-ply laminates composite plate under thermo-mechanical effect
...Show More Authors

The paper presents mainly the dynamic response of an angle ply composite laminated plates subjected to thermo-mechanical loading. The response are analyzed by analytically using Newmark direct integration method with Navier solution, numerically by ANSYS. The experimental investigation is to fabricate the laminates and to find mechanical and thermal properties of glass-polyester such as longitudinal, transverse young modulus, shear modulus, longitudinal and transverse thermal expansion. Present of temperature could increase dynamic response of plate also depending on lamination angle, type of mechanical load and the value of temperature.

 

View Publication Preview PDF
Publication Date
Mon Nov 11 2019
Journal Name
Spe
Modeling Rate of Penetration using Artificial Intelligent System and Multiple Regression Analysis
...Show More Authors
Abstract<p>Over the years, the prediction of penetration rate (ROP) has played a key rule for drilling engineers due it is effect on the optimization of various parameters that related to substantial cost saving. Many researchers have continually worked to optimize penetration rate. A major issue with most published studies is that there is no simple model currently available to guarantee the ROP prediction.</p><p>The main objective of this study is to further improve ROP prediction using two predictive methods, multiple regression analysis (MRA) and artificial neural networks (ANNs). A field case in SE Iraq was conducted to predict the ROP from a large number of parame</p> ... Show More
View Publication Preview PDF
Crossref (7)
Crossref
Publication Date
Wed Jun 01 2016
Journal Name
Lap Lambert Academic Publishing
Schiff Base And Ligand Metal Complexes of Some Amino Acids and Drug
...Show More Authors

Schiff Base And Ligand Metal Complexes of Some Amino Acids and Drug

Publication Date
Fri Nov 29 2019
Journal Name
Iraqi Journal Of Physics
Band Gap Characterization of Thermally Treated Hybrid Blend ZnPc/CdS Thin Films
...Show More Authors

Spin coating technique used to prepare ZnPc, CdS and ZnPc/CdS blend thin films, these films annealed at 423K for 1h, 2h and 3h. Optical behavior of these films were examined using UV-Vis. and PL. The absorption spectrum of ZnPc shows a decreasing in absorption with the increase of annealing time while CdS spectrum give a clearly absorption peak at~510 nm. Energy gap of ZnPc increases from 1.41 to 1.52 eV by increasing the annealing time. Eg of CdS decrease by increasing annealing time, from 2.3 eV to 2.2 eV. The intensities of the peaks obtained from PL spectra were strongly dependent on annealing time and confirmed the results obtained from UV-Vis. D.C. conductivity measurement showed that all the thin films have two differen

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Mar 28 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Response Surface Methodology for Development and Optimization of Theophylline Pulmonary Delivery System
...Show More Authors

The aim of the present study was to develop theophylline (TP) inhalable sustained delivery system by preparing solid lipid microparticles using glyceryl behenate (GB) and poloxamer 188 (PX) as a lipid carrier and a surfactant respectively. The method involves loading TP nanoparticles into the lipid using high shear homogenization – ultrasonication technique followed by lyophilization. The compositional variations and interactions were evaluated using response surface methodology, a Box – Behnken design of experiment (DOE). The DOE constructed using TP (X1), GB (X2) and PX (X3) levels as independent factors. Responses measured were the entrapment efficiency (% EE) (Y1), mass median

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Oct 14 2021
Journal Name
Iraqi Journal Of Physics
Investigation of nonlinear optical properties for laser dyes-doped polymer thin film
...Show More Authors

Solutions of dyes Rhodamine 6G (Rh6G) and Coumarin480(C480) were prepared at five concentrations (1x10-3, 5x10-4, 1x10-4, 5x10-5 and1x10-5) mol/l, the mixing was stirred to obtain on a homogenous solution, the(poly methyl-methacrylate) (PMMA) was solved by chloroform solvent with certain ratio, afterward (PMMA+Rh6G) and (PMMA+C480) thin films were prepared by casting method on glass block which has substrate with dimensions (7.5 x2.5)cm2, the prepared samples were left in dark place at room temperature for 24 hours to obtain uniform and homogenous thin films. UV-VIS absorption spectra, transmission spectra and fluorescence spectra were done to measure linear refractive index and linear absorption coefficient. The nonlinear optical proper

... Show More
View Publication Preview PDF
Publication Date
Wed Mar 29 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Poly Acrylamide Gel Electrophoresis of Serum Protein, Application to Kala-azar Patients
...Show More Authors

         Sera samples were collected from 60 children aged 4-60 months, all were clinically and serologically proven cases of visceral leishmaniasis, as well as  from 10 healthy children, all were seronegative with no history of parasitic infection who serve as a control during the study. Serum total protein and albumin were measured and compared between the control and visceral leishmaniasis patients. Serum protein profiles have been investigated using the conventional sodium dodecyl sulphate – polyacrylamide gel electrophoresis (SDS-PAGE).  Serum of control group showed the specific protein pattern with five protein bands, while serum protein profile in visceral leishmaniasis pat

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Feb 07 2019
Journal Name
Iraqi Journal Of Laser
Treatment of Skin Hyperpigmentation using Q-Switched (1064nm and 532nm) Nd:YAG Laser
...Show More Authors

Hyperpigmentation is the increase in the natural color of the skin. The purpose of this study is to evaluate the efficacy and safety of Q-Switched Nd:YAG (1064 & 532 nm) Laser in treatment of skin hyper pigmentation. This study was done in the research clinic of Institute of laser for postgraduate Studies/University of Baghdad from October 2008 to the end of January 2009. After clinical assessment of skin hyperpigmentation color, twenty six patients were divided according to their lesions. Eight Patients with freckles, seven patients with melasma, four patients with tattoo. Cases with tattoo, were subdivided into amateur tattoos two, professional tattoos one, and one traumatic tattoo. Four Patients with post inflammatory hyperpigment

... Show More
View Publication Preview PDF
Publication Date
Wed Oct 09 2019
Journal Name
Engineering, Technology &amp; Applied Science Research
Serviceability of Reinforced Concrete Gable Roof Beams with Openings under Static Loads
...Show More Authors

This paper presents an analytical study on the serviceability of reinforced concrete gable roof beams with openings of different sizes, based on an experimental study which includes 13 concrete gable roof beams with openings under static loading. For deflection and crack widths under static loading at service stage, a developed unified calculation procedure has been submitted, which includes prismatic beams with one opening subjected to flexure concentrated force. The deflection has been calculated with two methods: the first method calculated deflections via relevant equations and the second was Direct Stiffness Method in which the beam is treated as a structural member with several segments constituting the portions with solid sec

... Show More
View Publication Preview PDF
Crossref (17)
Crossref
Publication Date
Wed Nov 14 2018
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Simulation of Batch Reactive Distillation for Biodiesel Production from Oleic Acid Esterification
...Show More Authors

The present work concerns with simulating unsteady state equilibrium model for production of methyl oleate (biodiesel) from reaction of oleic acid with methanol using sulfuric acid as a catalyst in batch reactive distillation. MESHR equations of equilibrium model were solved using MATLAB (R2010a). The validity of simulation model was tested by comparing the simulation results with a data available in literature. UNIQUAC liquid phase activity coefficient model is the most appropriate model to describe the non-ideality of OLAC-MEOH-MEOL-H2O system. The chemical reactions rates results from EQ model indicating the rates are controlled by chemical kinetics. Several variables was studied such as molar ratio of methanol to oleic acid 4:1, 6:1

... Show More
View Publication Preview PDF