Preferred Language
Articles
/
jbcd-946
An Evaluation of the Efficacy of Different Gingival Retraction Materials on the Gingival Tissue Displacement (A Comparative In Vivo Study)
...Show More Authors

Background: An accurate adaptation of the crown to the finish line is essential to minimize cement dissolution and to preserve periodontium in fixed partial denture cases. An accurate adaptation of crown is possible only when preparation details are captured adequately in the impression and transferred to cast. For these reasons, gingival displacement is necessary to capture subgingival preparation details.The aim of the present study is to measure in vivo the horizontal displacement of the gingival sulcus obtained by using three new cordless retraction materials (Magic Foam Cord®, Racegel and Astringent Retraction Paste) in comparison to medicated retraction cord. Materials and method: Thirty-two patients requiring porcelain fused to metal fixed partial denture for replacement of a missing maxillary posterior tooth (either one of thepremolars or the first molar). The patients are randomly divided into four groups of eight patients each according to the type of gingival retraction material used as follows: Group I: Medicated retraction cord (racemic epinephrine hydrochloride 0.3 ± 0.2 mg per inch of cord, #00), Group II: Magic Foam Cord® (expanding polyvinyl siloxane), Group III: Racegel (25% aluminum chloride gel) and Group IV: Astringent Retraction Paste (15% aluminum chloride paste). Three depth orientation grooves were prepared in the buccal and palatal surfaces of a maxillary premolar parallel with the long axis of the tooth, extending from the middle third to the gingival third with the level of the free gingiva using a flat-ended diamond fissure bur. Impression of the gingival sulcus was then made using monophase polyether impression material (Impregum™ Penta™ Soft, 3M ESPE, Germany), before and after gingival retraction with either of the aforementioned gingival retraction materials. The sulcus width, before and after gingival retraction was measured on the master cast (in µm), after its sectioning longitudinally bucco-palatally at the middle of the prepared grooves using a rotary diamond disc. The measurement carried out by using digital microscope (Dino-Lite)at a magnification of 230X. The horizontal gingival displacement (the distance from the end of each prepared groove to the crest of the gingiva) measured by subtracting the gingival sulcus width after retraction from that before retraction. Results: The findings of the present study showed that the highest mean of horizontal gingival displacement is recorded by Group IV (Astringent Retraction Paste) (250.7900 µm), whereas the lowest mean of horizontal gingival displacement is recorded by Group III (Racegel) (78.0988 µm). One-way ANOVA test showed statistically highly significant differences among groups (p< 0.01). Least Significant Difference test (LSD test) was also used to make multiple comparisons among groups and revealed a statistically highly significant difference between each two groups (p< 0.01). Conclusion: The two new gingival retraction pastes (Astringent Retraction Paste and Magic Foam Cord®) could be used for gingival retraction as alternatives to medicated retraction cord. They offer advantages of simplified placement technique and shorter application time with greater gingival retraction. Meanwhile, the use of Racegel alone is not recommended for gingival retraction since it provides the least gingival displacement.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Sep 01 2023
Journal Name
Journal Of Ecological Engineering
Removal of Nitrate from Aqueous Solution by Bio-Calcium from Iraqi Eggshells
...Show More Authors

View Publication
Scopus (5)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Fri Apr 05 2019
Journal Name
International Journal Of Nanoelectronics And Materials
Characterization and Responsivity of Graphene Loaded Zinc Sulphide within Visible Light Spectrum
...Show More Authors

In this study, the nanocrystal-ZnS-loaded graphene was synthesized by a facile coprecipitation route. The effect of graphene on the characterization of Zinc Sulphide (ZnS) was investigated. The X-ray Diffraction (XRD) results reveal that ZnS has cubic system while hexagonal structure which is observed by loading graphene during the preparation of ZnS. Energy Dispersive X-ray Spectroscopy (EDS) analysis proved the presence of all expected elements in the prepared materials. Nanosize of fabricated materials has been measured using Scanning Electron Microscopy (SEM) technique. This study also found that the graphene plays a critical role in lowering the optical energy gap of ZnS nanoparticles from 4 eV to 3.2 eV. The characterization of detec

... Show More
Scopus (2)
Scopus
Publication Date
Sun Nov 14 2021
Journal Name
2021 North American Power Symposium (naps)
Laplace Domain Modeling of Power Components for Transient Converter-Grid Interaction Studies
...Show More Authors

This paper introduces a Laplace-based modeling approach for the study of transient converter-grid interactions. The proposed approach is based on the development of two-port admittance models of converters and other components, combined with the use of numerical Laplace transforms. The application of a frequency domain method is aimed at the accurate and straightforward computation of transient system responses while preserving the wideband frequency characteristics of power components, such as those due to the use of high frequency semiconductive switches, electromagnetic interaction between inductive and capacitive components, as well as wave propagation and frequency dependence in transmission systems.

View Publication
Scopus (5)
Crossref (4)
Scopus Crossref
Publication Date
Thu Jan 01 2015
Journal Name
Ibn Al-haitham Journal For Pure And Applied Science
Synthesis and Characterization of New Phthalimides Containing 1,2,4-triazole and Imine Group
...Show More Authors

Several new derivatives of 1, 2, 4-triazoles linked to phthalimide moiety were synthesized through following multisteps. The first step involved preparation of 2, 2-diphthalimidyl ethanoic acid [2] via reaction of two moles of phthalimide with dichloroacetic acid. Treatment of the resulted imide with ethanol in the second step afforded 2, 2-diphthalimidyl ester [3] which inturn was introduced in reaction with hydrazine hydrate in the third step, producing the corresponding hydrazide derivative [4]. The synthesized hydazide was introduced in different synthetic paths including treatment with carbon disulfide in alkaline solution then with hydrazine hydrate to afford the new 1, 2, 4-triazole [10]. Reaction of compound [10] with different alde

... Show More
Publication Date
Sun Mar 01 2020
Journal Name
Journal Of Petroleum Research And Studies
Modeling of Oil Viscosity for Southern Iraqi Reservoirs using Neural Network Method
...Show More Authors

The calculation of the oil density is more complex due to a wide range of pressuresand temperatures, which are always determined by specific conditions, pressure andtemperature. Therefore, the calculations that depend on oil components are moreaccurate and easier in finding such kind of requirements. The analyses of twenty liveoil samples are utilized. The three parameters Peng Robinson equation of state istuned to get match between measured and calculated oil viscosity. The Lohrenz-Bray-Clark (LBC) viscosity calculation technique is adopted to calculate the viscosity of oilfrom the given composition, pressure and temperature for 20 samples. The tunedequation of state is used to generate oil viscosity values for a range of temperatu

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Thu Feb 26 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Load-deflection characteristics and force levels of coated nickel titanium orthodontic archwires
...Show More Authors

Background: Coated archwires have been introduced to improve esthetics during orthodontic treatment. Theaim of the present study was to evaluate and compare the load–deflection characteristics and force levels of six brands of coated nickel titanium orthodontic archwires using palatal and gingival deflection. Materials and methods: Ten round wires (0.016 inch) and ten rectangular wires (0.019x0.025 inch) were obtained from each of six brands (G&H, Opal, Ortho Technology, Dany, Hubit and Astar Companies). The load-deflection properties of these archwires were evaluated by the modified bending test usinga readymade dental arch model in both palatal and gingival directions at 37°C temperature using a universal material testing machi

... Show More
View Publication Preview PDF
Publication Date
Sun May 11 2014
Journal Name
World Journal Of Experimental Biosciences
Detection of hydrolytic enzymes produced by Azospirillum brasiliense isolated from root soil
...Show More Authors

Publication Date
Thu Feb 26 2026
Journal Name
Tikrit Journal Of Pure Science
Spectrophotometric Determination of Aluminum Using Alizarin Red S-Application to Pharmaceutical Preparations
...Show More Authors

View Publication
Publication Date
Wed May 31 2017
Journal Name
Journal Of Engineering
Synthesis of Nanozeolite NaA from Pure Source Material Using Sol Gel Method
...Show More Authors

In this work, the nano particles of Na-A zeolite were synthesized by sol –gel method. The samples were characterized by X-ray diffraction (XRD), X-ray  luorescence (XRF), Surface  area and pore volume, Atomic Force Microscope (AFM) and Fourier Transform Infrared Spectroscopy (FTIR). Results show that the nano A zeolite is with average crystal size is 74.77 nm., Si/Al ratio 1.03, BET surface area was 581.211m2/g and the pore volume for NaA was found equal to 0.355cm3/g.
 
 
 

View Publication Preview PDF
Publication Date
Sun Jan 13 2019
Journal Name
Iraqi Journal Of Physics
Radiological risk assessment of fuel fabrication facility at Al- Tuwaitha nuclear site
...Show More Authors

The specific activity of 29 soil samples collected from Fuel
Fabrication Facility FFF at AL-Tuwaitha site, 20 km south of
Baghdad were determined using HPGe detector in a low background
configuration, it's relative efficiency of 40%, and resolution of 2keV
for the 1332 keV gamma ray emission of 60Co. The range of activity
concentrations of 226Ra, 232Th and 40K were between (12.56-31.96),
(10.2-18.4) and (47.47-402.1) Bq/kg respectively. In order to assess
any radiological hazard to human health, the absorbed gamma dose
rate D in air at 1m above the ground surface was calculated in the
range (18.87 to 36.46) nGy/h; the outdoor annual effective dose
equivalent AEDE was evaluated to vary from 0.0039 to 0.0076

... Show More
View Publication
Crossref