Background: Implant stability is considered one of the most important factors affecting healing and successful osseointegration of dental implants. The aims of the study were to measure the implant stability quotient (ISQ) values during the healing period and to determine the factors that affect implant stability. Materials and methods: Thirty patients enrolled in the study (17 female, 13 male). They received 44 Implantium® Dental Implants located as the following: 22 implants in maxillary jaw, 22 implants in mandibular jaw from them 17 implants in anterior segment and 27 in posterior segment. The bone density determined using interactive CT scan and classified according to the Misch bone density classification (29 implants in (D3), 15 implants in (D4)). Resonance frequency analysis was used for direct measurement of implant stability on the day of implant placement and 8, 16 and 24 weeks after implant placement. Results: The lowest mean of average ISQ was at the 8th week (69.5) and then the mean increased to reach at the 24th week (76.8). Mandibular implants showed significantly higher ISQ values than maxillary implants. Implants placed in the posterior segment of the jaw had significantly higher ISQ values than implants in the anterior segment. A significant, positive linear correlation was observed between the implant diameter and the implant stability (r=0.343 p<0.001). Conclusion: Resonance frequency analysis was non-invasive diagnostic tool for detecting changes in implant stability during the healing period. The factors that affect implant stability were implant diameter and implant location (maxilla\ mandible, anterior\ posterior).
Simple, sensitive and economical spectrophotometric methods have been developed for the determination of cefixime in pure form. This method is based on the reaction of cefixime as n-electron donor with chloranil to give highly colored complex in ethanol which is absorb maximally at 550 nm. Beer's law is obeyed in the concentration ranges 5-250 µg ml-1 with high apparent molar absorptivities of 1.52×103 L.mole-1. cm-1.
A simple, accurate and rapid method for separation and determination of most commonly usedinsecticides in Iraq [thiamethoxam (Thi), imidacloprid (Imi), indoxacarb (Ind), and abamectin (Aba)] ispresented. The separation was performed by gradient reversed-phase high performance liquidchromatography on a C18 stationary phase column. The method was developed and validated. The-1mobile phase was a mixture of acetonitrile and water using gradient flow. The flow rate was 1.0 mL min .The optimum temperature of separation was 25 ºC. The detection was performed at multiple wavelengths.The analysis time was up to 10.5 minutes with retention times of 3.221, 3.854, 6.385, and 9.452 min for-1the studied insecticides. The linearity was in the range of 0.
... Show MoreBackground: University dental students perceived a higher level of stress prior to the final exam associated with raised salivary cortisol levels which could be considered as a useful noninvasive biomarker for measuring acute stress. Using a Helkimo anamnestic and clinical dysfunction scoring for temporomandibular disorders can give a better insight about the association of this marker and temporomandibular joint disorders. The aim of this study was to evaluation level of salivary cortisol in stressor students with temporomandibular disorder and the relation between this marker in relation to temporomandibular disorder severity. This might give a better understanding to the role of psychological stress as an etiological factor for developin
... Show MoreIn this paper, an experimental study has been conducted regarding the indication of resonance in chaotic semiconductor laser. Resonant perturbations are effective for harnessing nonlinear oscillators for various applications such as inducing chaos and controlling chaos. Interesting results have been obtained regarding to the effect of the chaotic resonance by adding the frequency on the systems. The frequency changes nonlinear dynamical system through a critical value, there is a transition from a periodic attractor to a strange attractor. The amplitude has a very relevant impact on the system, resulting in an optimal resonance response for appropriate values related to correlation time. The chaotic system becomes regular under
... Show MoreThe scholars of Arabic - may God reward them with the reward of the doers of good - laid down the rules of this language, the cycle of which never ceases to dazzle minds, so they adopted principles according to which they judged the denomination of this word, and the accusative of that, and determined in its light the worker and the done, until they reached us the rules and foundations of our dear language, and it is obvious that they differ. The origins of grammarians from one school of thought to another, or from one world to another, especially with regard to the subsidiary rules, and this difference was clearly reflected in what we have received from the rules, as we find a difference in the rulings that they restricted to the one fa
... Show MoreThe concept of deficit in public budget becomes a chronic economic phenomenon in most of the world, whether the advanced countries or developing countries. Despite the difference in the visions of the economic schools to accept or reject the deficit in public budget but the opinion that prevailed is the necessity of the state to reduce the public spending which led to a continuous deficits in the public budget which consequently increased the government borrowing ,increase income taxes and wealth, consequently this weakened the in motivation in private investment which contributed to the increase of in factionary stagnation , so that governments have to cover the lack of local funding sources which become difficult to be eq
... Show MoreEight patients (3 male and 5 female) were treated in this study by Endovenous Laser Ablation (EVLA); Mathematical models are proposed to estimate the applied laser power and to assess the recovery period. The estimations of the applied laser power and recovery period in these models will be depended mainly on the diameter of the incompetent vein. In addition, Excel Program was utilized to find the proposed models. A 1470 nm diode laser up to 15W continuous power (CW) was used in the treatment of venous ulcers by EVLA procedure. Following up by duplex ultrasound was started in the 1st week after the first session until the vein is completely closed. The present study concluded that the relationship both between
... Show MoreAbstract Objective: The underlying molecular basis of ischemic heart diseases (IHDs) has not yet been studied among Iraqi people. This study determined the frequency and types of some cardiovascular genetic risk factors among Iraqi patients with IHDs. Methods: This is a cross-sectional study recruiting 56 patients with acute IHD during a 2-month period excluding patients >50 years and patients with documented hyperlipidemia. Their ages ranged between 18 and 50 years; males were 54 and females were only 2. Peripheral blood samples were aspirated from all patients for troponin I and DNA testing. Molecular analysis to detect 12 common cardiovascular genetic risk factors using CVD StripAssay® (ViennaLab Diagnostics GmbH, Austria) was performed
... Show MoreIn this research, a sensor for chemical solutions was designed and formed using optical fiber-based on a surface Plasmon resonance technology. A single-mode optical fiber with three different diameters (25, 45 and 65) µm was used, respectively. The second layer of the low refractive fiber was replaced by gold, which was electrically deposited at 40 µm thickness. For each of the three types of optical fiber, different saline concentrations (different index of refraction) were used to evaluate the performance of the refractive index sensor (chemical sensor) by measuring its sensitivity and resolutions. The highest values we could get for these two parameters were 240mm/RIU, and 6*10-5 RIU respectively, when the diameter of a
... Show More