Background: Implant stability is considered one of the most important factors affecting healing and successful osseointegration of dental implants. The aims of the study were to measure the implant stability quotient (ISQ) values during the healing period and to determine the factors that affect implant stability. Materials and methods: Thirty patients enrolled in the study (17 female, 13 male). They received 44 Implantium® Dental Implants located as the following: 22 implants in maxillary jaw, 22 implants in mandibular jaw from them 17 implants in anterior segment and 27 in posterior segment. The bone density determined using interactive CT scan and classified according to the Misch bone density classification (29 implants in (D3), 15 implants in (D4)). Resonance frequency analysis was used for direct measurement of implant stability on the day of implant placement and 8, 16 and 24 weeks after implant placement. Results: The lowest mean of average ISQ was at the 8th week (69.5) and then the mean increased to reach at the 24th week (76.8). Mandibular implants showed significantly higher ISQ values than maxillary implants. Implants placed in the posterior segment of the jaw had significantly higher ISQ values than implants in the anterior segment. A significant, positive linear correlation was observed between the implant diameter and the implant stability (r=0.343 p<0.001). Conclusion: Resonance frequency analysis was non-invasive diagnostic tool for detecting changes in implant stability during the healing period. The factors that affect implant stability were implant diameter and implant location (maxilla\ mandible, anterior\ posterior).
Two series of 1,3,4-oxadiazole derivatives at the sixth position of the 2,4-di-
Background: Non-atherosclerotic spontaneous coronary artery dissection (SCAD) is defined as a non-traumatic and non-iatrogenic separation of the coronary arterial wall. SCAD is a highly uncommon cause of myocardial infarction (0.1 to 0.4 %).
Case presentation: 40-year-old African American woman, G1T1P0A0L2, with a past medical history of tobacco abuse and obesity who had uncomplicated cesarean section delivery for healthy twins two weeks prior presented with substernal, sudden onset chest pain. The pain radiated to left arm and back, pressure-like, and is associated with nausea, vomiting, and dyspnea.
On examination she was within normal limits except for a well-healed C-section wound. An electrocardiogr
... Show MoreBackground: migraine is a chronic neurovascular disorder characterized by intermittent attacks of sever headache with or without aura that can include various combinations of neurological, gastrointestinal tract (G.I.T), and autonomic changes, without evidence of primary structural abnormalities. The Autonomic nervous system involvement suggested by many symptoms and signs including nausea, diarrhea, constipation, coldness in the extremities, paroxysmal tachycardia and chest pain.
Objectives: To evaluate autonomic functions in patients with migraine and to clarify the autonomic dysfunction weather its sympathetic, parasympathetic, or combined. Also to assess the severity of this dysfunction and its relation to age, gender and type of
A simple indirect spectrophotometric method for determination of mebendazol in pure and pharmaceutical formulation was presented in this study. UV-Visible spectrophotometry using the optimal conditions was developed for determination of mebendazole in pure drug and different preparation samples. The method is based on the oxidation of drug by nbromosuccinimide with hydrochloric acid and the left amount of oxidizing agent was determined by the reaction with tartarazine and the absorbance was measured at 428 nm. Calibration curves were linear in the range of 5 to 30 µg.mL-1 with molar absorptivity 8437.2 L.mol-1 .cm-1 . The limits of detection and quantification were determined and found to be 0.7770 µg.mL-1 and 2.3400 µg.mL-1 respec
... Show MoreTwo main grand bus national stations in Baghdad ( Alawi-alhila and Bab-almudam) were chosen as examples to determine lead effect on its drivers. This lead came from ethyl tetra lead or ethyl tri lead which used to improve gasoline quality ,so these two stations could be consider as two of the most polluted places due to gasoline burned by hundreds cars located in these stations .The determination of environmental lead pollution was measured in blood and urines drivers. Drivers were divided in two main groups due to their ages ( 30 persons in each group). The first group for men of 22-30 years old. The second group for men of 40-60 years old. Those men were carefully chosen in order to be non-fumiers or non-alcoholics persons because of
... Show MoreNew membrane electrodes for determination of ciprofloxacin hydrochloride were prepared depending on ciprofloxacin hydrochloride - phosphotungstic acid (CFH-PT) as an active material and these electrodes were made with three plasticizers: Di-octylphenylphosphonate(DOPH), Di-butyl phosphate (DBP)Tri-n-butyl phosphate(TBP), in PVC matrix. One of the ciprofloxacin electrodes was gave Nernstian slope equal to 57.21 mV/ decade for DOPH membrane with concentration range from 1.5×10-5 to1.0×10-1 M, and detection limit equal to 1.5×10-6 M .Lifetime was 93 days. Non- Nernstian responses equal to 39.40 and 30.70 mV/ decade for membranes DBP, TBP, respectively. These electrodes were gave concentration range from 1.0× 10-5 to 1.0×10-2 and from 4.0
... Show MoreA simple and rapid high performance liquid chromatographic with fluorescence detection method for the determination of the aflatoxin B1, B2, G1 and G2 in peanuts, rice and chilli was developed. The sample was extracted using acetonitrile:water (90:10, v/v%) and then purified by using ISOLUTE multimode solid phase extraction. After the pre-column derivatisation, the analytes were separated within 3.7 min using Chromolith performance RP-18e (100–4.6 mm) monolithic column. To assess the possible effects of endogenous components in the food items, matrix-matched calibration was used for the quantification and validation. The recoveries of aflatoxins that were spiked into food samples were 86.38–104.5% and RSDs were <4.4%. The method was
... Show MoreAn easy, eclectic, precise high-Performance Liquid Chromatographic (HPLC) procedure was evolved and validated to estimate of Piroxicam and Codeine phosphate. Chromatographic demarcation was accomplished on a C18 column [Use BDS Hypersil C18, 5μ, 150 x 4.6 mm] using a mobile phase of methanol: phosphate buffer (60:40, v/v, pH=2.3), the flow rate was 1.1 mL/min, UV detection was at 214 nm. System Suitability tests (SSTs) are typically performed to assess the suitability and effectiveness of the entire chromatography system. The retention time for Piroxicam was found to be 3.95 minutes and 1.46 minutes for Codeine phosphate. The evolved method has been validated through precision, limit of quantitation, specificity,
... Show More