Background: The study was designed to evaluate the effect of local application of exogenous VEGF/collagen I separately and as a combination in socket healing. Sixty male Albino Wistar rats were subjected for a surgical tooth extraction of upper 1st molar of both sides (right side was considered as experimental site, while left be the control one, treated with 1µL of normal saline). The rats were scarified at 3, 7, 14, 28 days post extraction. Socket healing was histologically examined with immunohistochemistochemical localization of ALP&FGF2. Materials and Method: Sixty male Albino Wistar rats were subjected for a surgical tooth extraction of upper 1stmolar of both sides (right side was considered as experimental site, while left be the control one). The animals were divided into following groups according to the applicable of biomaterials. A. Control group the tooth socket treated with 1μL of normal saline B. Experimental group includes • Group I contains (20) rats, the tooth socket treated with 1μL of VEGF • Group II contains (20) rats the tooth socket treated with 1μL of collagen type I • Group III contains (20) rats, the tooth socket treated with 1μL of a combination of VEGF and collagen I. Results: At 28 days all groups show re-epithelization but in different thickness, and with newly bone apposition and with different maturity. For positive cells expressed ALP, VEGF group records a high mean values at 3, 14, 28 days periods and with high differences in comparison to other groups while control group reports a high mean value at 7 days . For positive cells expressed FGF2. Control group illustrates a high record for the mean of positive cells expressed FGF2 at 3,7days periods and with high differences in comparison to other groups, while combination group reports a high mean value at 14 days . Conclusion: Results, high lighted on the effect of local application of VEGF in extracted tooth socket that facilitate epithelization, while combination of (collagen and VEGF) shows a high mineralization zone.
A theoretical study to design a conformal microstrip antennas was introduced in this work. Conformal microstrip antennas define antennas which can be conformed to a certain shape or to any curved surface. It is used in high-speed trains, aircraft, defense and navigation systems, landing gear and various communications systems, as well as in body wearable. Conformal antennas have some advantages such as a wider-angle coverage compared to flat antennas and low radar cross-sectional (RCS) and they are suitable for using in Radome. The main disadvantage of these antennas is the narrow bandwidth. The FDTD method is extremely useful in simulating complicated structures because it allows for direct integration of Maxwell's equations depending o
... Show MoreThis work deals with thermal cracking of heavy vacuum gas oil which produced from the top of vacuum distillation unit at Al- DURA refinery, by continuous process. An experimental laboratory plant scale was constructed in laboratories of chemical engineering department, Al-Nahrain University and Baghdad University. The thermal cracking process was carried out at temperature ranges between 460-560oC and atmospheric pressure with liquid hourly space velocity (LHSV) equal to 15hr-1.The liquid product from thermal cracking unit was distilled by atmospheric distillation device according to ASTM D-86 in order to achieve two fractions, below 220oC as a gasoline fraction and above 220oC as light cycle o
... Show MoreAbstract
In this work, diabetic glucose concentration level control under disturbing meal has been controlled using two set of advanced controllers. The first set is sliding mode controllers (classical and integral) and the second set is represented by optimal LQR controllers (classical and Min-, ax). Due to their characteristic features of disturbance rejection, both integral sliding mode controller and LQR Minmax controller are dedicated here for comparison. The Bergman minimal mathematical model was used to represent the dynamic behavior of a diabetic patient’s blood glucose concentration to the insulin injection. Simulations based on Matlab/Simulink, were performed to verify the performance of each controll
... Show MoreTwo- dimensional numerical simulations are carried out to study the elements of observing a Dirac point source and a Dirac binary system. The essential features of this simulation are demonstrated in terms of the point spread function and the modulation transfer function. Two mathematical equations have been extracted to present, firstly the relationship between the radius of optical telescope and the distance between the central frequency and cut-off frequency of the optical telescope, secondly the relationship between the radius of the optical telescope and the average frequency components of the modulation transfer function.
This research aims to conduct a linguistic analysis of the translation of the novel "The Corpse Washer" by the Iraqi author Sinan Antoon. The main objective is to explore the challenges and strategies involved in translating this literary work, particularly the difficulties in translating the Baghdadi dialect and the obstacles it poses for non-native speakers. Employing a descriptive research methodology, the study examines the linguistic aspects of the translation, specifically selected conversational texts in the novel. It identifies the difficulties faced by translators in preserving the essence of the original novel and presents instances where errors occurred in translating vocabulary, conversational expressions, proverbs, and idi
... Show MoreMass transfer has been studied at rotating cylinder electrodes fabricated with spiral-wound woven-wire meshes using reduction of copper as a test reaction. The experimental data were correlated by an empirical expression between the Sherwood number and the Reynolds number, both regarding the hydraulic diameter as a characteristic length. It was found that the Sherwood number was dependent upon the Reynolds number to the power of 0.521. An enhancement factor was adopted to compare the efficiency of the new rotating cylinder electrode with previous three-dimensional rotating cylinder electrodes. The results showed that the new type has a mass-transfer enhancement factor 2.3 times higher than those obtained with smooth rotating cylinder electr
... Show MoreTreatises concerning analyzing the interior spaces multiplied and their directions varied, that some of them analyzed the interior space on the basis of the intellectual and philosophical affiliation or the historical period and others in the light of the concept and mechanisms of the shape. The researcher has not been able to find a research that dealt with analyzing the space within the systems of shape generation, thus it is possible to determine the research problem with the following question: to what extent is it possible to analyze the interior space based on systems of shape generation? As far as the importance of the research is concerned, it sheds light on five of the systems of the shape generation which are: Syntax, shape gra
... Show MoreThis paper proposes a new approach, of Clustering Ultrasound images using the Hybrid Filter (CUHF) to determine the gender of the fetus in the early stages. The possible advantage of CUHF, a better result can be achieved when fuzzy c-mean FCM returns incorrect clusters. The proposed approach is conducted in two steps. Firstly, a preprocessing step to decrease the noise presented in ultrasound images by applying the filters: Local Binary Pattern (LBP), median, median and discrete wavelet (DWT),(median, DWT & LBP) and (median & Laplacian) ML. Secondly, implementing Fuzzy C-Mean (FCM) for clustering the resulted images from the first step. Amongst those filters, Median & Laplace has recorded a better accuracy. Our experimental evaluation on re
... Show MoreBackground: The ideal force-delivery system must: provide optimal tooth moving forces that elicit the desired effects, be comfortable and hygienic for the patient, require minimal operator manipulation and patient cooperation and provide rapid tooth movement with minimal mobility during orthodontic therapy, the elastomeric chains have the greatest potential to fulfill these requirements. Materials and Methods: This in vitro study was designed to determine the effect of three different mechanisms for canine retraction : (6-3 , 6-5-3 and chain loop ) on the load relaxation behavior of three types of elastomeric chains : (maximum clear , maximum silver and extreme silver) from the same company (Ortho Technology company) with two different bran
... Show More